3,3'-Dimethylbiphenyl
- Formula: C14H14
- Molecular weight: 182.2610
- IUPAC Standard InChIKey: GVEDOIATHPCYGS-UHFFFAOYSA-N
- CAS Registry Number: 612-75-9
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: 1,1'-Biphenyl, 3,3'-dimethyl-; m,m'-Bitolyl; 3,3'-Ditolyl; 3,3'-Dimethyldiphenyl; 3,3-Dimethyldiphenyl; 1-Methyl-3-(3'-methylphenyl)benzene; Biphenyl, 3,3'-dimethyl-; 3,3'-dimethyl-1,1'-biphenyl; Diphenyl, 3,3'-dimethyl
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Condensed phase thermochemistry data
Go To: Top, Phase change data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
ΔcH°liquid | -7529.9 ± 7.5 | kJ/mol | Ccb | Brull, 1935 | Reanalyzed by Cox and Pilcher, 1970, Original value = -7527.60 kJ/mol; Corresponding ΔfHºliquid = 20.0 kJ/mol (simple calculation by NIST; no Washburn corrections) |
Phase change data
Go To: Top, Condensed phase thermochemistry data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
BS - Robert L. Brown and Stephen E. Stein
AC - William E. Acree, Jr., James S. Chickos
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
Tboil | 559. | K | N/A | Blades, Blades, et al., 1954 | Uncertainty assigned by TRC = 8. K; TRC |
Tboil | 556. | K | N/A | Brull, 1935 | Uncertainty assigned by TRC = 3. K; TRC |
Tboil | 559. | K | N/A | Mayer and Freitak, 1921 | Uncertainty assigned by TRC = 3. K; TRC |
Tboil | 561. | K | N/A | Perrier, 1892 | Uncertainty assigned by TRC = 5. K; TRC |
Tboil | 562. | K | N/A | Stolle, 1888 | Uncertainty assigned by TRC = 5. K; TRC |
Quantity | Value | Units | Method | Reference | Comment |
Tfus | 278. | K | N/A | Castro, Andrews, et al., 1958 | Uncertainty assigned by TRC = 3. K; TRC |
Tfus | 282.4 | K | N/A | Johnson, 1957 | Uncertainty assigned by TRC = 1.5 K; TRC |
Tfus | 279. | K | N/A | Schultz, Rohde, et al., 1907 | Uncertainty assigned by TRC = 3. K; TRC |
Quantity | Value | Units | Method | Reference | Comment |
ΔvapH° | 71.9 | kJ/mol | A | Stephenson and Malanowski, 1987 | Based on data from 288. to 308. K. See also Pribilová and Pouchlý, 1974.; AC |
Quantity | Value | Units | Method | Reference | Comment |
ΔsubH° | 71.9 | kJ/mol | ME | Pribilová and Pouchlý, 1974 | Based on data from 288. to 308. K.; AC |
Reduced pressure boiling point
Tboil (K) | Pressure (bar) | Reference | Comment |
---|---|---|---|
559.2 | 0.951 | Aldrich Chemical Company Inc., 1990 | BS |
423.2 | 0.024 | Weast and Grasselli, 1989 | BS |
References
Go To: Top, Condensed phase thermochemistry data, Phase change data, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Brull, 1935
Brull, L.,
Sui calori di combustione di alcuni derivati del bifenil,
Gazz. Chim. Ital., 1935, 65, 19-28. [all data]
Cox and Pilcher, 1970
Cox, J.D.; Pilcher, G.,
Thermochemistry of Organic and Organometallic Compounds, Academic Press, New York, 1970, 1-636. [all data]
Blades, Blades, et al., 1954
Blades, H.; Blades, A.; Steacie, E.W.R.,
The Kinetics of Pyrolysis of Toluene,
Can. J. Chem., 1954, 32, 298-311. [all data]
Mayer and Freitak, 1921
Mayer, F.; Freitak, K.,
Chem. Ber., 1921, 54, 347. [all data]
Perrier, 1892
Perrier, G.,
Bull. Soc. Chim. Fr., 1892, 7, 180. [all data]
Stolle, 1888
Stolle, E.,
Chem. Ber., 1888, 21, 1096. [all data]
Castro, Andrews, et al., 1958
Castro, C.E.; Andrews, L.J.; Keefer, R.M.,
Molecular Complexes of Hindered Biphenyl Derivatives,
J. Am. Chem. Soc., 1958, 80, 2322-6. [all data]
Johnson, 1957
Johnson, E.A.,
J. Chem. Soc., 1957, 1957, 4155. [all data]
Schultz, Rohde, et al., 1907
Schultz, G.; Rohde, G.; Vicari, F.,
Justus Liebigs Ann. Chem., 1907, 352, 111. [all data]
Stephenson and Malanowski, 1987
Stephenson, Richard M.; Malanowski, Stanislaw,
Handbook of the Thermodynamics of Organic Compounds, 1987, https://doi.org/10.1007/978-94-009-3173-2
. [all data]
Pribilová and Pouchlý, 1974
Pribilová, J.; Pouchlý, J.,
Vapour pressure of some low-volatile hydrocarbons determined by the effusion method,
Collect. Czech. Chem. Commun., 1974, 39, 5, 1118-1124, https://doi.org/10.1135/cccc19741118
. [all data]
Aldrich Chemical Company Inc., 1990
Aldrich Chemical Company Inc.,
Catalog Handbook of Fine Chemicals, Aldrich Chemical Company, Inc., Milwaukee WI, 1990, 1. [all data]
Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]
Notes
Go To: Top, Condensed phase thermochemistry data, Phase change data, References
- Symbols used in this document:
Tboil Boiling point Tfus Fusion (melting) point ΔcH°liquid Enthalpy of combustion of liquid at standard conditions ΔsubH° Enthalpy of sublimation at standard conditions ΔvapH° Enthalpy of vaporization at standard conditions - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.