Cyclohexane, 1-methyl-4-(1-methylethyl)-, cis-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase SE-30SqualaneApiezon LSqualaneApiezon L
Column length (m) 64.100.45.50. 
Carrier gas HeHe H2 
Substrate     Chromosorb W AW
Column diameter (mm) 0.250.250.250.2 
Phase thickness (μm)      
Temperature (C) 80.80.100.100.130.
I 989.9994.71018.973.1027.
ReferenceAlbaigés and Guardino, 1980Albaigés and Guardino, 1980Morishita, Okano, et al., 1980Mitra, Mohan, et al., 1974Paris and Alexandre, 1972
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPacked
Active phase SE-30SqualaneMethyl Silicone
Column length (m)  15. 
Carrier gas N2He 
Substrate  Chromosorb P 
Column diameter (mm)  0.25 
Phase thickness (μm)    
Temperature (C) 130.86.130.
I 1000.998.1000.
ReferenceMitra and Saha, 1970Hively and Hinton, 1968Antheaume and Guiochon, 1965
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Albaigés and Guardino, 1980
Albaigés, J.; Guardino, X., Gas chromatographic-mass spectrometric identification of alkylcyclohexanes and cyclohexenes, Chromatographia, 1980, 13, 12, 755-762, https://doi.org/10.1007/BF02265555 . [all data]

Morishita, Okano, et al., 1980
Morishita, F.; Okano, T.; Kojima, T., Retention indices of monocyclic monoterpene hydrocarbons, Bunseki Kagaku, 1980, 29, 1, 48-53, https://doi.org/10.2116/bunsekikagaku.29.48 . [all data]

Mitra, Mohan, et al., 1974
Mitra, G.D.; Mohan, G.; Sinha, A., Gas chromatographic analysis of complex hydrocarbon mixtures, J. Chromatogr. A, 1974, 91, 633-648, https://doi.org/10.1016/S0021-9673(01)97944-0 . [all data]

Paris and Alexandre, 1972
Paris, C.; Alexandre, P., Stereochemical Investigation of Cyclohexane and Terpene Compounds by Gas Chromatography, J. Chromatogr. Sci., 1972, 10, 6, 402-411, https://doi.org/10.1093/chromsci/10.6.402 . [all data]

Mitra and Saha, 1970
Mitra, G.D.; Saha, N.C., Determination of Retention Indices of Saturated Hydrocarbons by Graphical Methods, J. Chromatogr. Sci., 1970, 8, 2, 95-102, https://doi.org/10.1093/chromsci/8.2.95 . [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]

Antheaume and Guiochon, 1965
Antheaume, J.; Guiochon, G., Application de la chromatographie en phase gazeuse à l'étude de la composition des fractions moyennes d'un brut pétrolier, Bull. Soc. Chim. Fr., 1965, 2, 298-307. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References