Cholesterol
- Formula: C27H46O
- Molecular weight: 386.6535
- IUPAC Standard InChIKey: HVYWMOMLDIMFJA-VUDDDUNTSA-N
- CAS Registry Number: 57-88-5
- Chemical structure:
This structure is also available as a 2d Mol file - Stereoisomers:
- Other names: Cholest-5-en-3-ol (3β)-; (-)-Cholesterol; Cholest-5-en-3β-ol; Cholesterin; Cholesterol base H; Cholesteryl alcohol; Cordulan; Dusoline; Dusoran; Dythol; Hydrocerin; Kathro; Lanol; Nimco cholesterol base H; Nimco cholesterol base No. 712; Provitamin D; Tegolan; Wool alcohols B. P.; 3β-Hydroxycholest-5-ene; 5-Cholesten-3β-ol; Cholestrin; Cholestrol; Super hartolan; 5,6-Cholesten-3β-ol; Δ5-Cholesten-3-β-ol; Cholesterine; Dastar; Fancol CH; (3β)-Cholest-5-en-3-ol; Cholest-5-en-3beta-ol; Lidinite; NSC 8798; Cholest-5-en-3-ol; 5-Cholesten-3B-ol; Cholest-5-en-3b-ol
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Packed | SE-30 | 230. | 3020. | Keiser, Retunskii, et al., 1990 | N2; Column length: 1.2 m |
Packed | SE-30 | 240. | 3034. | Keiser, Retunskii, et al., 1990 | N2; Column length: 1.2 m |
Packed | SE-30 | 250. | 3051. | Keiser, Retunskii, et al., 1990 | N2; Column length: 1.2 m |
Packed | E-301 | 220. | 3043. | Keiser, Retunskii, et al., 1990 | N2; Column length: 1.2 m |
Packed | E-301 | 230. | 3023. | Keiser, Retunskii, et al., 1990 | N2; Column length: 1.2 m |
Packed | E-301 | 230. | 3053. | Keiser, Retunskii, et al., 1990 | N2; Column length: 1.2 m |
Packed | E-301 | 240. | 3044. | Keiser, Retunskii, et al., 1990 | N2; Column length: 1.2 m |
Capillary | CP Sil 5 CB | 270. | 3068. | van Gelder, Jonker, et al., 1988 | 50. m/0.22 mm/0.12 μm, H2 |
Capillary | BP-1 | 275. | 3093. | Japp, Gill, et al., 1987 | 25. m/0.22 mm/0.25 μm, N2 |
Packed | SE-30 | 230. | 3020. | Keiser, Yazlovetsky, et al., 1986 | N2; Column length: 1.2 m |
Packed | SE-30 | 240. | 3034. | Keiser, Yazlovetsky, et al., 1986 | N2; Column length: 1.2 m |
Packed | SE-30 | 250. | 3051. | Keiser, Yazlovetsky, et al., 1986 | N2; Column length: 1.2 m |
Packed | OV-1 | 260. | 3071. | Quilliam and Westmore, 1978 | Gas Chrom Q; Column length: 1. m |
Packed | SE-30 | 225. | 3005. | Knights, 1966 | Gas Chrom P AW DMCS; Column length: 1. m |
Kovats' RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Packed | SE-30 | 3008. | Ramsey, Lee, et al., 1980 | He, Chromosorb G HP (80-100 mesh); Column length: 1.5 m; Program: not specified |
Packed | OV-1 | 3090. | Berninger, Grunnagel, et al., 1975 | N2, Chromosorb G, AW-DMCS; Column length: 2. m; Program: not specified |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5MS | 3075. | Steiner, Steidle, et al., 2005 | 30. m/0.32 mm/0.25 μm, He, 2. K/min; Tstart: 150. C; Tend: 300. C |
Capillary | Ultra-1 | 3004. | Tokuda, Saitoh, et al., 1988 | 12.5 m/0.20 mm/0.11 μm, He, 5. K/min, 325. C @ 5. min; Tstart: 120. C |
Capillary | DB-1 | 3081. | Perrigo, Peel, et al., 1985 | 15. m/0.32 mm/0.25 μm, He, 8. K/min, 280. C @ 5. min; Tstart: 120. C |
Capillary | DB-1 | 3081. | Perrigo, Ballantyne, et al., 1984 | 15. m/0.25 mm/0.25 μm, He, 8. K/min, 280. C @ 5. min; Tstart: 120. C |
Capillary | SE-30 | 3041. | Anderson and Stafford, 1983 | 15. m/0.25 mm/0.25 μm, He, 5. K/min; Tstart: 100. C; Tend: 295. C |
Packed | SE-30 | 3080. | Perrigo and Peel, 1981 | N2, Chromosorb W, 130. C @ 2. min, 8. K/min, 290. C @ 8. min; Column length: 1.8 m |
Normal alkane RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Packed | SE-30 | 230. | 3100. | Baidarovtseva, Rudenko, et al., 1976 | Column length: 1.3 m |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-1 | 3098. | Steiger, Haberer, et al., 2011 | 30. m/0.25 mm/0.25 μm, Helium, 10. K/min; Tstart: 50. C; Tend: 250. C |
Packed | SE-30 | 3080. | Peel and Perrigo, 1976 | Nitrogen, Chromosorb W AW DMS (80-100 mesh), 130. C @ 2. min, 8. K/min, 290. C @ 8. min; Column length: 2. m |
Packed | SE-30 | 3080. | Peel and Perrigo, 1975 | N2, Chromosorb W AW DMS, 130. C @ 2. min, 8. K/min, 290. C @ 8. min; Column length: 2. m |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | 3098. | Steiger, Peschke, et al., 2007 | Program: not specified | |
Capillary | OV-1 | 3093. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
Capillary | OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc. | 3041. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
Other | Methyl Silicone | 3008. | Ardrey and Moffat, 1981 | Program: not specified |
Other | Methyl Silicone | 3020. | Ardrey and Moffat, 1981 | Program: not specified |
Other | Methyl Silicone | 3086. | Ardrey and Moffat, 1981 | Program: not specified |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Keiser, Retunskii, et al., 1990
Keiser, L.S.; Retunskii, V.N.; Yazlovetskii, I.G.,
Gas chromatographic identification of sterols in insects. Estimation of retention data reproducibility,
Zh. Anal. Khim., 1990, 45, 1767-1773. [all data]
van Gelder, Jonker, et al., 1988
van Gelder, W.M.J.; Jonker, H.H.; Huizing, H.J.; Scheffer, J.J.C.,
Capillary gas chromatography of steroidal alkaloids from Solanaceae. Retention indices and simultaneous flame ionization/nitrogen-specific detection,
J. Chromatogr., 1988, 442, 133-145, https://doi.org/10.1016/S0021-9673(00)94463-7
. [all data]
Japp, Gill, et al., 1987
Japp, M.; Gill, R.; Osselton, M.D.,
Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns,
J. Forensic Sci., 1987, 32, 6, 1574-1586. [all data]
Keiser, Yazlovetsky, et al., 1986
Keiser, L.S.; Yazlovetsky, I.G.; Retunsky, V.N.,
Gas-chromatographic indentification of sterols in insects with the use of two-dimentional three-phase diagrams plotted on the basis of logarithmic retention indices,
J. Anal. Chem. USSR (Engl. Transl.), 1986, 41, 9, 1166-1172. [all data]
Quilliam and Westmore, 1978
Quilliam, M.A.; Westmore, J.B.,
Sterically crowded trialkylsilyl derivatives for chromatography and mass spectrometry of biologically-important compounds,
Anal. Chem., 1978, 50, 1, 59-68, https://doi.org/10.1021/ac50023a020
. [all data]
Knights, 1966
Knights, B.A.,
Application of retention indices to steroid gas chromatography,
J. Gas Chromatogr., 1966, 4, 9, 329-331, https://doi.org/10.1093/chromsci/4.9.329
. [all data]
Ramsey, Lee, et al., 1980
Ramsey, J.D.; Lee, T.D.; Osselton, M.D.; Moffat, A.C.,
Gas-liquid chromatographic retention indices of 296 non-drug substances on SE-30 or OV-1 likely to be encountered in toxicological analyses,
J. Chromatogr., 1980, 184, 2, 185-206, https://doi.org/10.1016/S0021-9673(00)85641-1
. [all data]
Berninger, Grunnagel, et al., 1975
Berninger, H.; Grunnagel, R.; Mall, S.; Moller, M.R.,
Gas chromatographic identification of unknown substances from body fluids by menas of retention indices,
Beitr. Gerichtl. Med., 1975, 33, 185-191. [all data]
Steiner, Steidle, et al., 2005
Steiner, S.; Steidle, J.L.M.; Ruther, J.,
Female sex pheromone in immature insect males - a case of pre-emergence chemical mimicry?,
Behavioral Ecology and Sociobiology, 2005, 58, 2, 111-120, https://doi.org/10.1007/s00265-005-0930-x
. [all data]
Tokuda, Saitoh, et al., 1988
Tokuda, H.; Saitoh, E.; Kimura, Y.; Takano, S.,
Automated analysis of various compounds with a wide range of boiling points by capillary gas chromatgraphy based on retention indices,
J. Chromatogr., 1988, 454, 109-120, https://doi.org/10.1016/S0021-9673(00)88606-9
. [all data]
Perrigo, Peel, et al., 1985
Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J.,
Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology.,
J. Chromatogr., 1985, 341, 81-88, https://doi.org/10.1016/S0378-4347(00)84011-6
. [all data]
Perrigo, Ballantyne, et al., 1984
Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W.,
Condierations in developing a data base for drugs on a DBI capillary column,
J. Can. Soc. Forensic Sci., 1984, 17, 2, 41-49, https://doi.org/10.1080/00085030.1984.10757360
. [all data]
Anderson and Stafford, 1983
Anderson, W.H.; Stafford, D.T.,
Applications of capillary gas chromatography in routine toxicological analyses,
J. Hi. Res. Chromatogr. Chromatogr. Comm., 1983, 6, 5, 247-254, https://doi.org/10.1002/jhrc.1240060506
. [all data]
Perrigo and Peel, 1981
Perrigo, B.J.; Peel, H.W.,
The use of retention indices and temperature-programmed gas chromatography in analytical toxicology,
J. Chromatogr. Sci., 1981, 19, 5, 219-226, https://doi.org/10.1093/chromsci/19.5.219
. [all data]
Baidarovtseva, Rudenko, et al., 1976
Baidarovtseva, M.A.; Rudenko, B.A.; Kuleshova, M.I.; Kucherov, V.F.,
Gas-chromatographic separation of free sterols using steam as the mobile phase,
Chem. Nat. Compd. (Engl. Transl.), 1976, 11, 6, 765-767, https://doi.org/10.1007/BF00568465
. [all data]
Steiger, Haberer, et al., 2011
Steiger, S.; Haberer, W.; Muller, J.K.,
Social environment determines degree of chemical signalling (Supplemented matherials),
Biol. Lett., 2011, 7, 6, 822-824, https://doi.org/10.1098/rsbl.2011.0457
. [all data]
Peel and Perrigo, 1976
Peel, H.W.; Perrigo, B.,
A practical gas chromatographic screening procedure for toxicological analysis,
Can. Soc. Forens. Sci. J., 1976, 9, 2, 69-74, https://doi.org/10.1080/00085030.1976.10757247
. [all data]
Peel and Perrigo, 1975
Peel, H.W.; Perrigo, B.,
A practical gas chromatographic screening procedure for toxicological analysis,
Can.Soc.Forens.Sci.J., 1975, 9, 2, 69-74, https://doi.org/10.1080/00085030.1976.10757247
. [all data]
Steiger, Peschke, et al., 2007
Steiger, S.; Peschke, K.; Francke, W.; Muller, J.K.,
The smell of parents: breeding status influences cuticular hydrocarbon pattern in the burying beetle Nicrophorus vespilloides,
Proc. Roy. Soc. B, 2007, 274, 1622, 2211-2220, https://doi.org/10.1098/rspb.2007.0656
. [all data]
Waggott and Davies, 1984
Waggott, A.; Davies, I.W.,
Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]
Ardrey and Moffat, 1981
Ardrey, R.E.; Moffat, A.C.,
Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase,
J. Chromatogr., 1981, 220, 3, 195-252, https://doi.org/10.1016/S0021-9673(00)81925-1
. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.