3-Ethylbiphenyl

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
BS - Robert L. Brown and Stephen E. Stein

Quantity Value Units Method Reference Comment
Tboil559.11KN/AGoodman and Wise, 1951Uncertainty assigned by TRC = 1. K; TRC
Quantity Value Units Method Reference Comment
Tfus245.58KN/AGoodman and Wise, 1951Uncertainty assigned by TRC = 0.2 K; TRC

Reduced pressure boiling point

Tboil (K) Pressure (bar) Reference Comment
416.20.015Weast and Grasselli, 1989BS

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Gas Chromatography

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryApiezon L200.1628.Krupcík, Leclercq, et al., 1980N2; Column length: 50. m; Column diameter: 0.25 mm
PackedApiezon L170.1621.Kríz, Popl, et al., 1974 
PackedApiezon L185.1633.Kríz, Popl, et al., 1974 

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillarySP-1000185.2234.Kríz, Popl, et al., 1974N2; Column length: 50. m; Column diameter: 0.25 mm
CapillarySP-1000200.2190.Kríz, Popl, et al., 1974N2; Column length: 50. m; Column diameter: 0.25 mm

References

Go To: Top, Phase change data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Goodman and Wise, 1951
Goodman, I.A.; Wise, P.H., Synthesis & purification of some alkylbiphenyls & alkylbicyclohexyls., Natl. Advis. Comm. Aeronaut., Tech. Note NACA TN 2260, Lewis Flight Propulsion Lab., Cleveland, Ohio, 1951. [all data]

Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]

Krupcík, Leclercq, et al., 1980
Krupcík, J.; Leclercq, P.A.; Garaj, J.; Símová, A., Analysis of alkylated mixtures of polychlorinated biphenyls by capillary gas chromatography-mass spectrometry, J. Chromatogr., 1980, 191, 207-220, https://doi.org/10.1016/S0021-9673(00)86381-5 . [all data]

Kríz, Popl, et al., 1974
Kríz, J.; Popl, M.; Mostecký, J., Retention indices of biphenyls and diphenylalkanes, J. Chromatogr., 1974, 97, 1, 3-13, https://doi.org/10.1016/S0021-9673(01)97577-6 . [all data]


Notes

Go To: Top, Phase change data, Gas Chromatography, References