2-Pentene, 2,3,4-trimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryPetrocol DH30.779.5Soják, Addová, et al., 2004150. m/0.25 mm/1. μm, H2
CapillarySqualane30.764.8Soják, Addová, et al., 2004He; Column length: 93. m; Column diameter: 0.25 mm
CapillaryOV-10140.773.Laub and Purnell, 1988 
CapillaryOV-10160.774.Laub and Purnell, 1988 
CapillaryOV-10180.776.Laub and Purnell, 1988 
CapillaryOV-10150.773.5Boneva and Dimov, 1986100. m/0.27 mm/0.9 μm, N2
CapillaryOV-10170.774.8Boneva and Dimov, 1986100. m/0.27 mm/0.9 μm, N2
CapillarySqualane50.765.7Boneva and Dimov, 1986N2; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane70.767.Boneva and Dimov, 1986N2; Column length: 100. m; Column diameter: 0.25 mm
PackedSqualane80.767.Chrétien and Dubois, 1977 
CapillarySqualane50.766.Chretien and Dubois, 1976 
CapillarySqualane50.766.Rijks and Cramers, 1974N2; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane70.767.Rijks and Cramers, 1974N2; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane40.766.Matukuma, 1969N2; Column length: 91.4 m; Column diameter: 0.25 mm
PackedSqualane30.765.5Tourres, 1967H2; Column length: 10. m
PackedSqualane50.766.Tourres, 1967H2; Column length: 10. m

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryMethyl Silicone50.766.N/AN2; Column length: 74.6 m; Column diameter: 0.28 mm

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryPetrocol DH780.Sojak, Kubinec, et al., 2006150. m/0.25 mm/1.0 μm, 1. K/min; Tstart: 40. C; Tend: 300. C
CapillaryPetrocol DH780.Sojak, Kubinec, et al., 2006150. m/0.25 mm/1.0 μm, 1. K/min; Tstart: 40. C; Tend: 300. C
CapillaryOV-101773.Orav, Kailas, et al., 199950. m/0.20 mm/0.50 μm, Helium, 30. C @ 6. min, 1. K/min; Tend: 100. C

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Soják, Addová, et al., 2004
Soják, L.; Addová, G.; Kubinec, R.; Kraus, A.; Bohác, A., Capillary gas chromatography-mass spectrometry of all 93 acyclic octenes and their identification in fluid catalytic cracked gasoline, J. Chromatogr. A, 2004, 1025, 2, 237-253, https://doi.org/10.1016/j.chroma.2003.10.112 . [all data]

Laub and Purnell, 1988
Laub, R.J.; Purnell, J.H., Specific retention volumes, retention indices, and family-plot regressions of aliphatic, alicyclic, and aromatic hydrocarbon solutes with OV-101 poly (dimethylsiloxane) stationary phase, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1988, 11, 9, 649-660, https://doi.org/10.1002/jhrc.1240110908 . [all data]

Boneva and Dimov, 1986
Boneva, S.; Dimov, N., Gas Chromatographic Retention Indices for Alkenes on OV-101 and Squalane Capillary Columns, Chromatographia, 1986, 21, 3, 149-151, https://doi.org/10.1007/BF02311743 . [all data]

Chrétien and Dubois, 1977
Chrétien, J.R.; Dubois, J.E., Topological analysis of gas-liquid chromatographic behavior of alkenes, Anal. Chem., 1977, 49, 6, 747-756, https://doi.org/10.1021/ac50014a021 . [all data]

Chretien and Dubois, 1976
Chretien, J.R.; Dubois, J.-E., New Perspectives in the Prediction of Kovats Indices, J. Chromatogr., 1976, 126, 171-189, https://doi.org/10.1016/S0021-9673(01)84071-1 . [all data]

Rijks and Cramers, 1974
Rijks, J.A.; Cramers, C.A., High precision capillary gas chromatography of hydrocarbons, Chromatographia, 1974, 7, 3, 99-106, https://doi.org/10.1007/BF02269819 . [all data]

Matukuma, 1969
Matukuma, A., Retention indices of alkanes through C10 and alkenes through C8 and relation between boiling points and retention data, Gas Chromatogr., Int. Symp. Anal. Instrum. Div Instrum Soc. Amer., 1969, 7, 55-75. [all data]

Tourres, 1967
Tourres, D.A., Structural analysis of industrial butene dimers by gas chromatography, J. Gas Chromatogr., 1967, 5, 1, 35-40, https://doi.org/10.1093/chromsci/5.1.35 . [all data]

Sojak, Kubinec, et al., 2006
Sojak, L.; Kubinec, R.; Jurdakova, H.; Hajekova, E.; Bajus, M., GC-MS of polyethylene and polypropylene thermal cracking produxts, Petroleum Coal, 2006, 48, 1, 1-14. [all data]

Orav, Kailas, et al., 1999
Orav, A.; Kailas, T.; Muurisepp, M.; Kann, J., Composition of the oil from waste tires. 1. Fraction boiling at yp to 160 0C, Proc. Estonian Acad. Sci. Chem., 1999, 48, 1, 30-39. [all data]


Notes

Go To: Top, Gas Chromatography, References