3-Pentanone, 2-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal boiling point

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Tboil (K) Reference Comment
386.2Aldrich Chemical Company Inc., 1990BS
386.Kossanyi, 1960Uncertainty assigned by TRC = 3. K; TRC
384.15Smith, 1960Uncertainty assigned by TRC = 3. K; TRC
386.15Honjo, Miyamoto, et al., 1955Uncertainty assigned by TRC = 2. K; TRC
387.25Overberger, Hale, et al., 1954Uncertainty assigned by TRC = 1. K; TRC
387.15Overberger, Hale, et al., 1954Uncertainty assigned by TRC = 1. K; TRC
388.15Cook, 1952Uncertainty assigned by TRC = 1. K; TRC
388.2Ginnings, Plonk, et al., 1940Uncertainty assigned by TRC = 1. K; TRC
390.15Kharasch, Sternfeld, et al., 1940Uncertainty assigned by TRC = 1. K; TRC
387.7Bryant and Smith, 1935Uncertainty assigned by TRC = 1. K; TRC
386.15Ivanov and Spassov, 1935Uncertainty assigned by TRC = 2. K; TRC
386.Mayberry and Aston, 1934Uncertainty assigned by TRC = 0.5 K; TRC
387.65Burton, Shoppee, et al., 1933Uncertainty assigned by TRC = 1. K; TRC
388.15Graves, 1931Uncertainty assigned by TRC = 1. K; TRC
389.Hopff, 1931Uncertainty assigned by TRC = 2. K; TRC
387.9Michael, 1919Uncertainty assigned by TRC = 1. K; TRC
387.15Favorskii, 1913Uncertainty assigned by TRC = 2. K; TRC
390.15Haller and Bauer, 1913Uncertainty assigned by TRC = 3. K; TRC
390.65Haller and Bauer, 1910Uncertainty assigned by TRC = 5. K; TRC
368.15Sabatier and Senderens, 1903TRC; Data excluded from overall average
386.9Hanriot and Bouveault, 1889Uncertainty assigned by TRC = 1. K; TRC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


References

Go To: Top, Normal boiling point, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Aldrich Chemical Company Inc., 1990
Aldrich Chemical Company Inc., Catalog Handbook of Fine Chemicals, Aldrich Chemical Company, Inc., Milwaukee WI, 1990, 1. [all data]

Kossanyi, 1960
Kossanyi, J., Preparation of ε-Diketones by the Reduction of Vinyl Ketones, C. R. Hebd. Seances Acad. Sci., 1960, 250, 3487-8. [all data]

Smith, 1960
Smith, R.F., J. Org. Chem., 1960, 25, 453-54. [all data]

Honjo, Miyamoto, et al., 1955
Honjo, M.; Miyamoto; Ueyanagi; Nawa; Uchibayashi, Yakugaku Zasshi, 1955, 75, 853. [all data]

Overberger, Hale, et al., 1954
Overberger, C.G.; Hale, W.F.; Berenbaum, M.B.; Finestone, A.B., J. Am. Chem. Soc., 1954, 76, 6185. [all data]

Cook, 1952
Cook, N.C., , Unpublished, Final Rep. Stand. Proj. on Oxygenated Compounds, Penn. State Univ., College Park, PA, 1952. [all data]

Ginnings, Plonk, et al., 1940
Ginnings, P.M.; Plonk, D.; Carter, E., Aqueous Solubilities of Some Aliphatic Ketones, J. Am. Chem. Soc., 1940, 62, 1923-1924. [all data]

Kharasch, Sternfeld, et al., 1940
Kharasch, M.S.; Sternfeld, E.; Mayo, F.R., J. Org. Chem., 1940, 5, 362. [all data]

Bryant and Smith, 1935
Bryant, M.D.; Smith, D.M., Improved hydroxylamine method for the determination of aldehydes and ketones displacement of oxime equilibria by means of pyridine, J. Am. Chem. Soc., 1935, 57, 57. [all data]

Ivanov and Spassov, 1935
Ivanov; Spassov, Bull. Soc. Chim. Fr., 1935, 2, 816. [all data]

Mayberry and Aston, 1934
Mayberry, M.G.; Aston, J.G., Vapor pressure of certain ketones., J. Am. Chem. Soc., 1934, 56, 2682-3. [all data]

Burton, Shoppee, et al., 1933
Burton, H.B.; Shoppee, C.W.; Wilson, C.L., Anionotropic and prototropic changes in cyclic systems: I hydroxycyclopentenones, J. Chem. Soc., 1933, 1933, 720. [all data]

Graves, 1931
Graves, G.D., Ind. Eng. Chem., 1931, 23, 1381. [all data]

Hopff, 1931
Hopff, H., Chem. Ber., 1931, 64, 2739. [all data]

Michael, 1919
Michael, A., J. Am. Chem. Soc., 1919, 41, 393. [all data]

Favorskii, 1913
Favorskii, A., J. Prakt. Chem., 1913, 88, 641. [all data]

Haller and Bauer, 1913
Haller, A.; Bauer, E., Ann. Chim. (Paris), 1913, 29, 8, 313. [all data]

Haller and Bauer, 1910
Haller; Bauer, C. R. Hebd. Seances Acad. Sci., 1910, 150, 661. [all data]

Sabatier and Senderens, 1903
Sabatier, P.; Senderens, J.B., C. R. Hebd. Seances Acad. Sci., 1903, 137, 302. [all data]

Hanriot and Bouveault, 1889
Hanriot; Bouveault, L., Bull. Soc. Chim. Fr., 1889, 1, 548. [all data]


Notes

Go To: Top, Normal boiling point, References