Cyclooctasiloxane, hexadecamethyl-
- Formula: C16H48O8Si8
- Molecular weight: 593.2315
- IUPAC Standard InChIKey: XKJMJYZFAWYREL-UHFFFAOYSA-N
- CAS Registry Number: 556-68-3
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Hexadecamethyl-cyclooctasioxane; Hexadecamethylcyclooctasiloxane
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | Ultra-1 | 1693. | Richmond and Pombo-Villar, 1998 | 25. m/0.32 mm/0.52 μm, He, 15. K/min, 320. C @ 10. min; Tstart: 35. C |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | SP-2100 | 1688. | Fischer and Kusch, 1993 | He, 40. C @ 3. min, 5. K/min; Column length: 30. m; Column diameter: 0.25 mm; Tend: 280. C |
Capillary | Methyl Silicone | 1709. | Fujimoto, Ohtani, et al., 1990 | 25. m/0.25 mm/0.1 μm, He, 5. K/min; Tstart: 40. C; Tend: 350. C |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | Ultra-1 | 1700. | Kazuyoshi, Seiichi, et al., 2000 | 30. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min) |
Capillary | Ultra-1 | 1700. | Kazuyoshi, Seiichi, et al., 2000 | 30. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min) |
Capillary | Ultra-1 | 1706. | Kazuyoshi, Seiichi, et al., 2000 | 30. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min) |
Capillary | Ultra-1 | 1706. | Kazuyoshi, Seiichi, et al., 2000 | 30. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min) |
Capillary | Ultra-1 | 1712. | Kazuyoshi, Seiichi, et al., 2000 | 30. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min) |
Capillary | Ultra-1 | 1712. | Kazuyoshi, Seiichi, et al., 2000 | 30. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min) |
Capillary | Ultra-1 | 1691. | Richmond and Pombo-Villar, 1998 | 25. m/0.32 mm/0.52 μm, He; Program: not specified |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Richmond and Pombo-Villar, 1998
Richmond, R.; Pombo-Villar, E.,
Short communication. Use of persistent trace gas chromatography artifacts for the calculation of pseudo-Sadtler retention indices,
J. Chromatogr. A, 1998, 811, 1-2, 241-245, https://doi.org/10.1016/S0021-9673(98)00285-4
. [all data]
Fischer and Kusch, 1993
Fischer, G.W.; Kusch, P.,
An Automated Curie-Point Pyrolysis-High Resolution Gas Chromatography System,
LC-GC Int., 1993, 6, 12, 760-763. [all data]
Fujimoto, Ohtani, et al., 1990
Fujimoto, S.; Ohtani, H.; Yamagiwa, K.; Tsuge, S.,
Study on retention behavior of cyclic siloxanes by high resolution pyrolysis-gas chromatography with a fused silica capillary column,
J. Hi. Res. Chromatogr., 1990, 13, 6, 397-404, https://doi.org/10.1002/jhrc.1240130603
. [all data]
Kazuyoshi, Seiichi, et al., 2000
Kazuyoshi, N.; Seiichi, Y.; Kazuo, K.; Katsumi, I.; Okihiko, S.,
Polymer analysis by improved pyrolysis gas chromatography hyphenated with four specific detectors,
J. Soc. Cosmet. Chem. Jpn., 2000, 34, 2, 142-151, https://doi.org/10.5107/sccj.34.142
. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.