L-Tryptophan, 3TMS derivative
- Formula: C20H36N2O2Si3
- Molecular weight: 420.7685
- IUPAC Standard InChIKey: JRAGJGVCQZJQIM-SFHVURJKSA-N
- CAS Registry Number: 55429-28-2
- Chemical structure:
This structure is also available as a 2d Mol file - Stereoisomers:
- Other names: L-Tryptophan, N,1-bis(trimethylsilyl)-, trimethylsilyl ester; L-Tryptophan, N,N'-trimethylsilyl-, trimethylsilyl ester; Trp, (N,N,O-tris-TMS); Tryptophan, N,N,O-triTMS; Trp, TMS; TRYPTOPHANE (N,N,O-TMS); TRYPTOPHAN,N,N,O-TMS
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | SP-2100 | 210. | 2218.50 | Gajewski, Dizdaroglu, et al., 1982 | He; Column length: 12. m; Column diameter: 0.2 mm |
Capillary | SE-54 | 190. | 2237.31 | Gajewski, Dizdaroglu, et al., 1982 | He; Column length: 12. m; Column diameter: 0.2 mm |
Kovats' RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | SP-2100 | 2208.39 | Gajewski, Dizdaroglu, et al., 1982 | He, 6. K/min; Column length: 12. m; Column diameter: 0.2 mm; Tstart: 80. C; Tend: 250. C |
Kovats' RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | SE-54 | 2235.62 | Gajewski, Dizdaroglu, et al., 1982 | He; Column length: 12. m; Column diameter: 0.2 mm; Program: 70C => 4C/min => 170C=8C/min => 250C |
Kovats' RI, polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | Carbowax 20M | 200. | 2548.52 | Gajewski, Dizdaroglu, et al., 1982 | He; Column length: 12. m; Column diameter: 0.2 mm |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5MS | 2208.3 | Jonsson, Johansson, et al., 2005 | 10. m/0.18 mm/0.18 μm, 70. C @ 2. min, 40. K/min, 320. C @ 2. min |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | VF-5MS | 2214.5 | Tret'yakov, 2007 | 30. m/0.25 mm/0.25 μm, He; Program: Multi-step temperature program; T(initial)=60C; T(final)=270C |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Gajewski, Dizdaroglu, et al., 1982
Gajewski, E.; Dizdaroglu, M.; Simic, M.G.,
Kovats' Indices of Trimethylsilylated Amino Acids on Fused-Silica Capillary Columns,
J. Chromatogr., 1982, 249, 1, 41-55, https://doi.org/10.1016/S0021-9673(00)80231-9
. [all data]
Jonsson, Johansson, et al., 2005
Jonsson, P.; Johansson, A.I.; Gullberg, J.; Trygg, J.; Jiye, A.; Grung, B.; Marklund, S.; Sjöström, M.; Antti, H.; Moritz, T.,
High-throughput data analysis for detecting and identifying differences between samples in GC/MS-based metabolomic analyses,
Anal. Chem., 2005, 77, 17, 5635-5642, https://doi.org/10.1021/ac050601e
. [all data]
Tret'yakov, 2007
Tret'yakov, K.V.,
Retention Data. NIST Mass Spectrometry Data Center., NIST Mass Spectrometry Data Center, 2007. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.