Hexane, 1-chloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-1HP-1HP-1HP-1
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.250.250.25
Temperature (C) 0.10.20.30.40.
I 840.1838.8839.5837.4835.
ReferenceWang, Liu, et al., 2005Wang, Liu, et al., 2005Wang, Liu, et al., 2005Wang, Liu, et al., 2005Wang, Liu, et al., 2005
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryPackedPacked
Active phase HP-1HP-1HP-1C78, Branched paraffinC78, Branched paraffin
Column length (m) 30.6.6.3.33.3
Carrier gas  HeHeHe 
Substrate     Chromosorb G HP
Column diameter (mm) 0.250.3100.310  
Phase thickness (μm) 0.250.520.52  
Temperature (C) 50.20.20.130.130.
I 833.7836.7840.9843.7842.9
ReferenceWang, Liu, et al., 2005Koutek, Cvacka, et al., 2001Koutek, Cvacka, et al., 2001Dallos, Sisak, et al., 2000Reddy, Dutoit, et al., 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedCapillaryCapillaryCapillaryCapillary
Active phase ApolaneOV-1OV-1SE-54SE-54
Column length (m) 3.725.25.25.25.
Carrier gas  HeHeHeHe
Substrate      
Column diameter (mm)  0.310.310.310.31
Phase thickness (μm)  0.520.520.520.52
Temperature (C) 130.60.75.60.75.
I 844.842.9844.6858.2859.7
ReferenceDutoit, 1991Guan, Kiraly, et al., 1989Guan, Kiraly, et al., 1989Guan, Kiraly, et al., 1989Guan, Kiraly, et al., 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPackedCapillaryPacked
Active phase Apiezon LApolaneSqualaneApiezon L
Column length (m) 45.2.4100. 
Carrier gas HeHe  
Substrate  Chromosorb Celite (40:60 Gewichtsverhaltnis)
Column diameter (mm) 0.25 0.25 
Phase thickness (μm)     
Temperature (C) 90.70.100.130.
I 857.833.3838.3835.
ReferenceMorishita, Terashima, et al., 1983Riedo, Fritz, et al., 1976Schomburg and Dielmann, 1973von Kováts, 1958
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Wang, Liu, et al., 2005
Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 2005, 81, 2, 184-190, https://doi.org/10.1016/j.microc.2005.02.003 . [all data]

Koutek, Cvacka, et al., 2001
Koutek, B.; Cvacka, J.; Streinz, L.; Vrkocová, P.; Doubský, J.; Simonová, H.; Feltl, L.; Svoboda, V., Comparison of methods employing gas chromatography retention data to determine vapour pressures at 298 K, J. Chromatogr. A, 2001, 923, 1-2, 137-152, https://doi.org/10.1016/S0021-9673(01)00965-7 . [all data]

Dallos, Sisak, et al., 2000
Dallos, A.; Sisak, A.; Kulcsár, Z.; Kováts, E., Pair-wise interactions by gas chromatography VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A, 2000, 904, 2, 211-242, https://doi.org/10.1016/S0021-9673(00)00908-0 . [all data]

Reddy, Dutoit, et al., 1992
Reddy, K.S.; Dutoit, J.-Cl.; Kovats, E. sz., Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr., 1992, 609, 1-2, 229-259, https://doi.org/10.1016/0021-9673(92)80167-S . [all data]

Dutoit, 1991
Dutoit, J., Gas chromatographic retention behaviour of some solutes on structurally similar polar and non-polar stationary phases, J. Chromatogr., 1991, 555, 1-2, 191-204, https://doi.org/10.1016/S0021-9673(01)87179-X . [all data]

Guan, Kiraly, et al., 1989
Guan, Y.; Kiraly, J.; Rijks, J.A., Interactive retention index database for compound identification in temperature-programmed capillary gas chromatography, J. Chromatogr., 1989, 472, 129-143, https://doi.org/10.1016/S0021-9673(00)94101-3 . [all data]

Morishita, Terashima, et al., 1983
Morishita, F.; Terashima, Y.; Ichise, M.; Kojima, T., Prediction of retention indices from molecular structures of chlorinated alkanes, J. Chromatogr. Sci., 1983, 21, 5, 209-213, https://doi.org/10.1093/chromsci/21.5.209 . [all data]

Riedo, Fritz, et al., 1976
Riedo, F.; Fritz, D.; Tarján, G.; Kováts, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 1976, 126, 63-83, https://doi.org/10.1016/S0021-9673(01)84063-2 . [all data]

Schomburg and Dielmann, 1973
Schomburg, G.; Dielmann, G., Identification by means of retention parameters, J. Chromatogr. Sci., 1973, 11, 3, 151-159, https://doi.org/10.1093/chromsci/11.3.151 . [all data]

von Kováts, 1958
von Kováts, E., 206. Gas-chromatographische Charakterisierung organischer Verbindungen. Teil 1: Retentionsindices aliphatischer Halogenide, Alkohole, Aldehyde und Ketone, Helv. Chim. Acta, 1958, 41, 7, 1915-1932, https://doi.org/10.1002/hlca.19580410703 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References