Cyclopentane, 1,1,3,3-tetramethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Quantity Value Units Method Reference Comment
Tboil391.19KN/AAnonymous, 1961Uncertainty assigned by TRC = 0.2 K
Tboil391.11KN/AGlasgow, Gordon, et al., 1957Uncertainty assigned by TRC = 0.3 K
Quantity Value Units Method Reference Comment
Tfus184.740KN/AAnonymous, 1961Uncertainty assigned by TRC = 0.3 K
Tfus184.86KN/ASlomp, 1951Uncertainty assigned by TRC = 0.3 K
Tfus184.9KN/AAnonymous, 1948Uncertainty assigned by TRC = 1. K
Tfus184.86KN/AAnonymous, 1945Uncertainty assigned by TRC = 0.3 K

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Gas Chromatography

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillarySqualane50.772.8Lunskii and Paizanskaya, 1988He; Column length: 50. m; Column diameter: 0.22 mm
CapillarySqualane70.776.9Lunskii and Paizanskaya, 1988He; Column length: 50. m; Column diameter: 0.22 mm

Kovats' RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryApiezon L765.Louis, 1971N2, 1. K/min; Column length: 50. m; Column diameter: 0.25 mm; Tstart: 60. C

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-101770.Orav, Kailas, et al., 199950. m/0.20 mm/0.50 μm, Helium, 30. C @ 6. min, 1. K/min; Tend: 100. C

References

Go To: Top, Phase change data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Anonymous, 1961
Anonymous, R., Preliminary thermodyn. prop. of FREON-14, E. I. Du Pont, Freon Tech. Bull. T-14, 1961. [all data]

Glasgow, Gordon, et al., 1957
Glasgow, A.R.; Gordon, R.J.; Willingham, C.B.; Mair, B.J.; Rossini, F.D., Hydrocarbons in the 116 deg C to 126 deg C Fraction of Petroleum, Anal. Chem., 1957, 29, 357. [all data]

Slomp, 1951
Slomp, G., , Ph.D. Thesis, Ohio State Univ., Columbus, OH, 1951. [all data]

Anonymous, 1948
Anonymous, R., , Am. Pet. Inst. Res. Proj. 6, Natl. Bur. Stand., 1948. [all data]

Anonymous, 1945
Anonymous, R., Private Commun., Am. Pet. Inst. Res. Proj. 45, 1945. [all data]

Lunskii and Paizanskaya, 1988
Lunskii, M.Kh.; Paizanskaya, I.L., Identification of hydrocarbons C1-C9 of petrol fractions of oils and condensates in the use of capillary columns with dinonylphthalate, Zh. Anal. Khim., 1988, 43, 127-135. [all data]

Louis, 1971
Louis, R., Kovats-index-tafeln zur gaschromatographischen analyse von kohlenwasserstoffgemischen, Erdoel Kohle Erdgas Petrochem., 1971, 24, 2, 88-94. [all data]

Orav, Kailas, et al., 1999
Orav, A.; Kailas, T.; Muurisepp, M.; Kann, J., Composition of the oil from waste tires. 1. Fraction boiling at yp to 160 0C, Proc. Estonian Acad. Sci. Chem., 1999, 48, 1, 30-39. [all data]


Notes

Go To: Top, Phase change data, Gas Chromatography, References