Limonene oxide, trans-
- Formula: C10H16O
- Molecular weight: 152.2334
- IUPAC Standard InChIKey: CCEFMUBVSUDRLG-UHFFFAOYSA-N
- CAS Registry Number: 4959-35-7
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
View 3d structure (requires JavaScript / HTML 5) - Species with the same structure:
- Stereoisomers:
- Other names: (E)-Limonene oxide; 4-Isopropenyl-1-methyl-7-oxabicyclo[4.1.0]heptane-, (1α,4β,6α)-; trans-Limonene oxide; trans-Limonene-1,2-epoxide-; trans-Limonene epoxide; trans-1,2-Limonene epoxide; 7-Oxabicyclo(4.1.0)heptane, 1-methyl-4-(1-methylethenyl)-, (1R,4S,6S)-; trans-1,2-Epoxy-p-menth-8-ene; 10373-59-8; 66141-65-9; trans-limonene-1,2-oxide; trans-Limonen-1,2-epoxide; trans-Limonen oxide; trans-1,2-limonene oxide; trans-Limonene oxyde; 1,2-Epoxylimonene, isomer # 1
- Information on this page:
- Other data available:
- Options:
Kovats' RI, non-polar column, temperature ramp
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | HP-5MS | SE-30 | SE-54 | HP-5 | SE-30 |
Column length (m) | 30. | 25. | 30. | 30. | 25. |
Carrier gas | He | He | He | N2 | |
Substrate | |||||
Column diameter (mm) | 0.25 | 0.22 | 0.26 | 0.25 | 0.2 |
Phase thickness (μm) | 0.25 | 0.25 | 0.25 | 0.25 | |
Tstart (C) | 60. | 70. | 60. | 60. | 60. |
Tend (C) | 280. | 220. | 246. | 280. | 180. |
Heat rate (K/min) | 3. | 4. | 3. | 4. | 3. |
Initial hold (min) | 10. | ||||
Final hold (min) | 1. | ||||
I | 1125. | 1146. | 1139. | 1137. | 1106. |
Reference | Gkinis, Tzakou, et al., 2003 | Palá-Paúl, Velasco-Negueruela, et al., 2002 | Adams, 2000 | Sajjadi and Ghassemi, 1999 | Jantan, Ahmad, et al., 1996 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary |
---|---|
Active phase | OV-101 |
Column length (m) | 50. |
Carrier gas | N2 |
Substrate | |
Column diameter (mm) | 0.25 |
Phase thickness (μm) | 0.2 |
Tstart (C) | 80. |
Tend (C) | 200. |
Heat rate (K/min) | 2. |
Initial hold (min) | |
Final hold (min) | 60. |
I | 1129. |
Reference | Padrayuttawat, Tamura, et al., 1996 |
Comment | MSDC-RI |
References
Go To: Top, Kovats' RI, non-polar column, temperature ramp, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Gkinis, Tzakou, et al., 2003
Gkinis, G.; Tzakou, O.; Iliopoulou, D.; Roussis, V.,
Chemical Composition and Biological Activity of Nepeta parnassica Oils and Isolated Nepetalactones,
Z. Naturforsch. C:, 2003, 58, 681-686. [all data]
Palá-Paúl, Velasco-Negueruela, et al., 2002
Palá-Paúl, J.; Velasco-Negueruela, A.; Pérez-Alonso, M.J.; Sanz, J.,
Essential oil composition of the aerial parts of Cachrys sicula L.,
Flavour Fragr. J., 2002, 17, 1, 64-68, https://doi.org/10.1002/ffj.1042
. [all data]
Adams, 2000
Adams, R.P.,
Systematics of the one seeded Juniperus of the eastern hemisphere based on leaf essential oils and random amplified polymorphic DNAs (RAPDs),
Biochem. Syst. Ecol., 2000, 28, 6, 529-543, https://doi.org/10.1016/S0305-1978(99)00096-4
. [all data]
Sajjadi and Ghassemi, 1999
Sajjadi, S.E.; Ghassemi, N.,
Volatile constituents of Nepeta glomerulosa Boiss. subsp. carmanica,
Flavour Fragr. J., 1999, 14, 5, 265-267, https://doi.org/10.1002/(SICI)1099-1026(199909/10)14:5<265::AID-FFJ822>3.0.CO;2-A
. [all data]
Jantan, Ahmad, et al., 1996
Jantan, I.; Ahmad, A.S.; Ahmad, A.R.; Ali, N.A.M.; Ayop, N.,
Chemical composition of some citrus oils from Malaysia,
J. Essent. Oil Res., 1996, 8, 6, 627-632, https://doi.org/10.1080/10412905.1996.9701030
. [all data]
Padrayuttawat, Tamura, et al., 1996
Padrayuttawat, A.; Tamura, H.; Yamao, M.,
A split injection system for the analysis of purge and trap headspace of the volatile components in Citrus sudachi,
J. Hi. Res. Chromatogr., 1996, 19, 6, 365-369, https://doi.org/10.1002/jhrc.1240190613
. [all data]
Notes
Go To: Top, Kovats' RI, non-polar column, temperature ramp, References
- Symbols used in this document:
Tend Final temperature Tstart Initial temperature - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.