Benzene, 1,2,3,4-tetramethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SPB-5HP-5Petrocol DHDB-5DB-5
Column length (m) 60.30.50.30.30.
Carrier gas  HeHeHeHe
Substrate      
Column diameter (mm) 0.320.250.250.250.25
Phase thickness (μm) 1.0.250.50.250.25
Tstart (C) 40.50.35.40.40.
Tend (C) 230.220.200.310.310.
Heat rate (K/min) 3.3.3.4.4.
Initial hold (min) 2. 10. 5.
Final hold (min) 10.20.10.  
I 1120.1122.1145.31149.91148.2
ReferenceEngel and Ratel, 2007Xian Q., Chen H., et al., 2006Censullo, Jones, et al., 2003Song, Lai, et al., 2003Song, Lai, et al., 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5DB-5OV-1DB-5
Column length (m) 30.30.30.25.30.
Carrier gas HeHeHe He
Substrate      
Column diameter (mm) 0.250.250.250.20.25
Phase thickness (μm) 0.250.250.250.330.25
Tstart (C) 40.40.40.100.40.
Tend (C) 310.310.310.180.310.
Heat rate (K/min) 2.4.6.5.2.
Initial hold (min)      
Final hold (min)      
I 1144.21149.91153.81175.21144.2
ReferenceSong, Lai, et al., 2003Song, Lai, et al., 2003Song, Lai, et al., 2003Zhang, Shen, et al., 2000Lai and Song, 1995
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5DB-5DB-5Petrocol DH
Column length (m) 30.30.30.30.100.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.250.250.5
Tstart (C) 40.40.40.40.30.
Tend (C) 310.310.310.310.220.
Heat rate (K/min) 4.6.4.4.1.
Initial hold (min)    5. 
Final hold (min)      
I 1149.91153.81149.91148.21135.84
ReferenceLai and Song, 1995Lai and Song, 1995Lai and Song, 1995Lai and Song, 1995White, Douglas, et al., 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase Petrocol DHOV-101
Column length (m) 100.108.
Carrier gas He 
Substrate   
Column diameter (mm) 0.250.25
Phase thickness (μm) 0.50.2
Tstart (C) 30.35.
Tend (C) 220.200.
Heat rate (K/min) 1.1.
Initial hold (min)   
Final hold (min)   
I 1136.1133.
ReferenceWhite, Hackett, et al., 1992Hayes and Pitzer, 1981
Comment MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Engel and Ratel, 2007
Engel, E.; Ratel, J., Correction of the data generated by mass spectrometry analyses of biological tissues: Application to food authentication, J. Chromatogr. A, 2007, 1154, 1-2, 331-341, https://doi.org/10.1016/j.chroma.2007.02.012 . [all data]

Xian Q., Chen H., et al., 2006
Xian Q.; Chen H.; Zou H.; Yin D., Chemical composition of essential oils of two submerged macrophytes, Ceratophyllum demersum L. and Vallisneria spiralis L., Flavour Fragr. J., 2006, 21, 3, 524-526, https://doi.org/10.1002/ffj.1588 . [all data]

Censullo, Jones, et al., 2003
Censullo, A.C.; Jones, D.R.; Wills, M.T., Speciation of the volatile organic compounds (VOCs) in solventborne aerosol coatings by solid phase microextraction-gas chromatography, J. Coat. Technol., 2003, 75, 936, 47-53, https://doi.org/10.1007/BF02697922 . [all data]

Song, Lai, et al., 2003
Song, C.; Lai, W.-C.; Madhusudan Reddy, K.; Wei, B., Chapter 7. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s)., Kluwer Academic/Plenum Publishers, New York, 2003, 147-193. [all data]

Zhang, Shen, et al., 2000
Zhang, M.-J.; Shen, S.-D.; Chen, S.-Y.; Sun, Y.-H., Analysis of heavy oil fractions in high-temperature coal tar by capillary gas chromatography/fourier transform infrared spectrometry, Chin. J. Chromatogr., 2000, 18, 3, 241-246. [all data]

Lai and Song, 1995
Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. and g.c.-m.s. analysis of coal- and petroleum-derived liquid fuels, Fuel, 1995, 74, 10, 1436-1451, https://doi.org/10.1016/0016-2361(95)00108-H . [all data]

White, Douglas, et al., 1992
White, C.M.; Douglas, L.J.; Hackett, J.P.; Anderson, R.R., Characterization of synthetic gasoline from the chloromethane-zeolite reaction, Energy Fuels, 1992, 6, 1, 76-82, https://doi.org/10.1021/ef00031a012 . [all data]

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]

Hayes and Pitzer, 1981
Hayes, P.C., Jr.; Pitzer, E.W., Kovats indices as a tool in characterizing hydrocarbon fuels in temperature programmed glass capillary gas chromatography. Part 1. Qualitative identification, Inhouse rpt. for Air Force Wright Aeronautical Labs., Air Force Wright Aeronautical Labs., Wright-Patterson AFB, Ohio, 1981, 75. [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References