Cyclopentane, 1,2,4-trimethyl-, (1α,2α,4β)-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase CP Sil 2OV-101OV-101OV-101Squalane
Column length (m) 100.   50.
Carrier gas     He
Substrate      
Column diameter (mm) 0.25   0.22
Phase thickness (μm) 0.25    
Temperature (C) 60.40.60.80.50.
I 784.4769.774.779.772.7
ReferenceEstel, Mohnke, et al., 1995Laub and Purnell, 1988Laub and Purnell, 1988Laub and Purnell, 1988Lunskii and Paizanskaya, 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSqualaneSqualaneOV-101OV-101
Column length (m) 50.180.180.  
Carrier gas He    
Substrate      
Column diameter (mm) 0.220.250.25  
Phase thickness (μm)      
Temperature (C) 70.50.50.30.40.
I 777.773.0774.8766.769.
ReferenceLunskii and Paizanskaya, 1988Krupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986Chien, Furio, et al., 1983Chien, Furio, et al., 1983
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101OV-101OV-101DB-1
Column length (m)     60.
Carrier gas      
Substrate      
Column diameter (mm)     0.264
Phase thickness (μm)      
Temperature (C) 50.60.70.80.60.
I 771.774.776.779.775.
ReferenceChien, Furio, et al., 1983Chien, Furio, et al., 1983Chien, Furio, et al., 1983Chien, Furio, et al., 1983Lubeck and Sutton, 1983
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-1OV-101OV-101SF-96Squalane
Column length (m) 60.100.55.91.4120.
Carrier gas     He
Substrate      
Column diameter (mm) 0.2590.270.270.310.25
Phase thickness (μm) 1.0.200.90.20 
Temperature (C) 60.50.50.50.100.
I 775.4740.740.740.737.
ReferenceLubeck and Sutton, 1983Johansen and Ettre, 1982Johansen and Ettre, 1982Johansen and Ettre, 1982Lulova, Leont'eva, et al., 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSqualaneSqualaneSqualaneVacuum Grease Oil (VM-4)
Column length (m) 120.120.100.100. 
Carrier gas HeHeN2N2 
Substrate      
Column diameter (mm) 0.250.250.250.25 
Phase thickness (μm)      
Temperature (C) 100.100.50.70.35.
I 778.8778.8773.777.771.
ReferenceLulova, Leont'eva, et al., 1976Lulova, Leont'eva, et al., 1976Rijks and Cramers, 1974Rijks and Cramers, 1974Sidorov, Petrova, et al., 1972
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)Squalane
Column length (m)     100.
Carrier gas      
Substrate      
Column diameter (mm)     0.25
Phase thickness (μm)      
Temperature (C) 45.50.58.68.70.
I 774.775.777.779.773.6
ReferenceSidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972Dimov and Schopov, 1971
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Vacuum Grease Oil (VM-4)SE-30SqualaneSqualaneSqualane
Column length (m)  6.115.15.15.
Carrier gas  N2HeHeHe
Substrate  Chromosorb WChromosorb PChromosorb PChromosorb P
Column diameter (mm)   0.250.250.25
Phase thickness (μm)      
Temperature (C) 35.130.27.49.67.
I 771.791.768.774.777.
ReferenceSidorov, Ivanova, et al., 1971Mitra and Saha, 1970Hively and Hinton, 1968Hively and Hinton, 1968Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Squalane
Column length (m) 15.
Carrier gas He
Substrate Chromosorb P
Column diameter (mm) 0.25
Phase thickness (μm)  
Temperature (C) 86.
I 782.
ReferenceHively and Hinton, 1968
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Estel, Mohnke, et al., 1995
Estel, D.; Mohnke; Biermans; Rotzsche, The analysis of C4-C11 hydrocarbons in naphtha and reformate with a new apolar fused silica column, J. Hi. Res. Chromatogr., 1995, 18, 7, 403-412, https://doi.org/10.1002/jhrc.1240180703 . [all data]

Laub and Purnell, 1988
Laub, R.J.; Purnell, J.H., Specific retention volumes, retention indices, and family-plot regressions of aliphatic, alicyclic, and aromatic hydrocarbon solutes with OV-101 poly (dimethylsiloxane) stationary phase, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1988, 11, 9, 649-660, https://doi.org/10.1002/jhrc.1240110908 . [all data]

Lunskii and Paizanskaya, 1988
Lunskii, M.Kh.; Paizanskaya, I.L., Identification of hydrocarbons C1-C9 of petrol fractions of oils and condensates in the use of capillary columns with dinonylphthalate, Zh. Anal. Khim., 1988, 43, 127-135. [all data]

Krupcik, Cellar, et al., 1986
Krupcik, J.; Cellar, P.; Repka, D.; Garaj, J.; Guiochon, G., Use of Kováts retention indices for characterization of solutes in linear temperature-programmed capillary gas-liquid chromatography, J. Chromatogr., 1986, 351, 111-121, https://doi.org/10.1016/S0021-9673(01)83477-4 . [all data]

Chien, Furio, et al., 1983
Chien, C.-F.; Furio, D.L.; Kopecni, M.M.; Laub, R.J., Specific Retention Volumes and Retention Indices of Selected Hydrocarbon Solutes with OV-101 and SP-2100 Polydimethylsiloxane Solvents, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1983, 6, 10, 577-580, https://doi.org/10.1002/jhrc.1240061013 . [all data]

Lubeck and Sutton, 1983
Lubeck, A.J.; Sutton, DL., Kovats retention indices of selected hydrocarbons through C10 on bonded phase fused silica capillaries, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1983, 6, 6, 328-332, https://doi.org/10.1002/jhrc.1240060612 . [all data]

Johansen and Ettre, 1982
Johansen, N.G.; Ettre, L.S., Retention index values of hydrocarbons on open-tubular columns coated with methylsilicone liquid phases, Chromatographia, 1982, 15, 10, 625-630, https://doi.org/10.1007/BF02279488 . [all data]

Lulova, Leont'eva, et al., 1976
Lulova, N.I.; Leont'eva, S.A.; Timofeeva, A.N., Gas-chromatographic method of determination of individual hydrocarbons in catalytic cracking gasolines in Proceedings of All-Union Research Institute on Oil Processes. Vol.18, All-Union Research Institute on Oil Processes, Moscow, 1976, 30-53. [all data]

Rijks and Cramers, 1974
Rijks, J.A.; Cramers, C.A., High precision capillary gas chromatography of hydrocarbons, Chromatographia, 1974, 7, 3, 99-106, https://doi.org/10.1007/BF02269819 . [all data]

Sidorov, Petrova, et al., 1972
Sidorov, R.I.; Petrova, V.I.; Ivanova, M.P., Qualitative analysis of wide-boiling fraction C5-C10 with capillary chromatography in Processes in chromatographic columns. Vol.17, 1972, 14-25. [all data]

Dimov and Schopov, 1971
Dimov, N.; Schopov, D., Empirische korrektion der physikalisch-chemischen retentionsindexe von kohlenwasserstoffen auf squalan, J. Chromatogr., 1971, 63, 223-228, https://doi.org/10.1016/S0021-9673(01)85634-X . [all data]

Sidorov, Ivanova, et al., 1971
Sidorov, R.I.; Ivanova, M.P.; Petrova, V.I., Temperature dependence of cycloalkane's retention and its using in identification of structure, Gazovaya Khromatografiya, 1971, 15, 18-26. [all data]

Mitra and Saha, 1970
Mitra, G.D.; Saha, N.C., Determination of Retention Indices of Saturated Hydrocarbons by Graphical Methods, J. Chromatogr. Sci., 1970, 8, 2, 95-102, https://doi.org/10.1093/chromsci/8.2.95 . [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]


Notes