Ergosta-5,22-dien-3-ol, (3β,22E)-


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin DR GLENN PATTERSON
NIST MS number 36790

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedSE-30230.3063.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedSE-30240.3085.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedSE-30250.3088.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedE-301210.3047.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedE-301220.3038.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedE-301220.3078.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedE-301230.3055.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedE-301230.3088.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedE-301240.3080.Keiser, Retunskii, et al., 1990N2; Column length: 1.2 m
PackedSE-30230.3063.Keiser, Yazlovetsky, et al., 1986N2; Column length: 1.2 m
PackedSE-30240.3085.Keiser, Yazlovetsky, et al., 1986N2; Column length: 1.2 m
PackedSE-30250.3088.Keiser, Yazlovetsky, et al., 1986N2; Column length: 1.2 m
PackedSE-30240.3044.Keiser, Yazlovetsky, et al., 1986N2; Column length: 1.2 m

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-1265.3115.Brooks, Cole, et al., 1980Helium; Column length: 25. m; Column diameter: 0.50 mm

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Keiser, Retunskii, et al., 1990
Keiser, L.S.; Retunskii, V.N.; Yazlovetskii, I.G., Gas chromatographic identification of sterols in insects. Estimation of retention data reproducibility, Zh. Anal. Khim., 1990, 45, 1767-1773. [all data]

Keiser, Yazlovetsky, et al., 1986
Keiser, L.S.; Yazlovetsky, I.G.; Retunsky, V.N., Gas-chromatographic indentification of sterols in insects with the use of two-dimentional three-phase diagrams plotted on the basis of logarithmic retention indices, J. Anal. Chem. USSR (Engl. Transl.), 1986, 41, 9, 1166-1172. [all data]

Brooks, Cole, et al., 1980
Brooks, C.J.W.; Cole, W.J.; McIntyre, H.B.; Smith, A.G., Selective reactions in the analysis and characterization of steroids by gas chromatography-mass spectrometry, Lipids, 1980, 15, 9, 745-755, https://doi.org/10.1007/BF02534028 . [all data]


Notes

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References