1,1,1,2,3,3-Hexafluoropropane
- Formula: C3H2F6
- Molecular weight: 152.0384
- IUPAC Standard InChIKey: FYIRUPZTYPILDH-UHFFFAOYSA-N
- CAS Registry Number: 431-63-0
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Propane, 1,1,1,2,3,3-hexafluoro-; R 236ea
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Phase change data
Go To: Top, Mass spectrum (electron ionization), References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
BS - Robert L. Brown and Stephen E. Stein
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
Tboil | 279.7 | K | N/A | Hwang, DesMarteau, et al., 1992 | Uncertainty assigned by TRC = 0.5 K; TRC |
Tboil | 279. | K | N/A | PCR Inc., 1990 | BS |
Quantity | Value | Units | Method | Reference | Comment |
Tc | 412.370 | K | N/A | Aoyama, Kishizawa, et al., 1996 | Uncertainty assigned by TRC = 0.03 K; For ITS-90 scale, includes review of and comparison with previous literture; TRC |
Quantity | Value | Units | Method | Reference | Comment |
ρc | 3.74 | mol/l | N/A | Aoyama, Kishizawa, et al., 1996 | Uncertainty assigned by TRC = 0.01 mol/l; at critical opalesence, includes review of and comparison with previous literature; TRC |
Mass spectrum (electron ionization)
Go To: Top, Phase change data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | Thomas J.Bruno |
NIST MS number | 215688 |
References
Go To: Top, Phase change data, Mass spectrum (electron ionization), Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Hwang, DesMarteau, et al., 1992
Hwang, S.H.; DesMarteau, D.D.; Beyerlein, A.L.; Smith, N.D.; Joyner, P.,
The heat capacity of fluorinated propane and butane derivatives by differential scanning calorimetry,
J. Therm. Anal., 1992, 38, 2515-28. [all data]
PCR Inc., 1990
PCR Inc.,
Research Chemicals Catalog 1990-1991, PCR Inc., Gainesville, FL, 1990, 1. [all data]
Aoyama, Kishizawa, et al., 1996
Aoyama, H.; Kishizawa, G.; Sato, H.; Watanabe, K.,
Vapor-Liquid Coexistence Curves in the Critical Region and the Critical Temperatures and Densities of 1,1,1,2-Tetrafluoroethane (R-134a), 1,1,1- Trifluoroethane (R-143a), and 1,1,1,2,3,3- Hexafluorop,
J. Chem. Eng. Data, 1996, 41, 1046-1051. [all data]
Notes
Go To: Top, Phase change data, Mass spectrum (electron ionization), References
- Symbols used in this document:
Tboil Boiling point Tc Critical temperature ρc Critical density - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.