Cyclopentane, (1,1-dimethylethyl)-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Quantity Value Units Method Reference Comment
Tboil417.95KN/ABoord, Greenlee, et al., 1946Uncertainty assigned by TRC = 0.2 K
Tboil418.1KN/ACrane, Boord, et al., 1945Uncertainty assigned by TRC = 1. K
Tboil417.99KN/ABoord, Perilstein, et al., 1944Uncertainty assigned by TRC = 0.2 K
Tboil418.4KN/APines and Ipatieff, 1939Uncertainty assigned by TRC = 1. K
Quantity Value Units Method Reference Comment
Tfus177.1 ± 0.2KAVGN/AAverage of 8 values; Individual data points

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Gas Chromatography

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillarySqualane50.877.5Lunskii and Paizanskaya, 1988He; Column length: 50. m; Column diameter: 0.22 mm
CapillarySqualane70.881.3Lunskii and Paizanskaya, 1988He; Column length: 50. m; Column diameter: 0.22 mm

References

Go To: Top, Phase change data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Boord, Greenlee, et al., 1946
Boord, C.E.; Greenlee, K.W.; Perilstein, W.L., The Synthesis, Purification and Prop. of Hydrocarbons of Low Mol. Weight, Am. Pet. Inst. Res. Proj. 45, Eighth Annu. Rep., Ohio State Univ., June 30, 1946. [all data]

Crane, Boord, et al., 1945
Crane, G.; Boord, C.E.; Henne, A.L., The Preparation of Cyclopentenes and Cyclopentanes I., J. Am. Chem. Soc., 1945, 67, 1237. [all data]

Boord, Perilstein, et al., 1944
Boord, C.E.; Perilstein, W.L.; Greenlee, K.W., , Am. Pet. Inst. Hydrocarbon Res. Proj., Sixth Annu. Ref., Ohio State Univ., Aug. 31, 1944. [all data]

Pines and Ipatieff, 1939
Pines, H.; Ipatieff, V.N., J. Am. Chem. Soc., 1939, 61, 2728. [all data]

Lunskii and Paizanskaya, 1988
Lunskii, M.Kh.; Paizanskaya, I.L., Identification of hydrocarbons C1-C9 of petrol fractions of oils and condensates in the use of capillary columns with dinonylphthalate, Zh. Anal. Khim., 1988, 43, 127-135. [all data]


Notes

Go To: Top, Phase change data, Gas Chromatography, References