2-Methyl-1,3-cyclopentadiene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-101100.644.Diez, Guillen, et al., 1990N2; Column length: 25. m; Column diameter: 0.23 mm
CapillaryOV-10180.642.Diez, Guillen, et al., 1990N2; Column length: 25. m; Column diameter: 0.23 mm
CapillarySqualane100.630.Diez, Guillen, et al., 1990N2; Column length: 45. m; Column diameter: 0.5 mm
CapillarySqualane80.627.5Diez, Guillen, et al., 1990N2; Column length: 45. m; Column diameter: 0.5 mm
CapillarySE-54100.653.8Diez, Guillen, et al., 1990N2; Column length: 25. m; Column diameter: 0.22 mm
CapillarySE-5480.649.6Diez, Guillen, et al., 1990N2; Column length: 25. m; Column diameter: 0.22 mm
PackedSqualane70.627.Safina, Poznyak, et al., 1989He, Risorb (0.2-0.3 mm); Column length: 2. m
PackedSqualane70.628.Safina, Poznyak, et al., 1989He, Risorb (0.2-0.3 mm); Column length: 2. m
CapillaryBP-1100.644.Bermejo, Blanco, et al., 1987N2; Column length: 12. m; Column diameter: 0.22 mm
CapillaryBP-180.641.Bermejo, Blanco, et al., 1987N2; Column length: 12. m; Column diameter: 0.22 mm
CapillaryOV-101100.644.Bermejo, Blanco, et al., 1987N2; Column length: 25. m; Column diameter: 0.23 mm
CapillaryOV-10180.642.Bermejo, Blanco, et al., 1987N2; Column length: 25. m; Column diameter: 0.23 mm
CapillarySqualane64.624.Sojak, Ruman, et al., 198750. m/0.25 mm/0.25 μm, H2
CapillarySqualane50.622.8Bajus, Veselý, et al., 1979Column length: 100. m; Column diameter: 0.25 mm
PackedSqualane100.631.Bogoslovsky, Anvaer, et al., 1978 
PackedSqualane27.621.Bogoslovsky, Anvaer, et al., 1978 
PackedSqualane49.624.Bogoslovsky, Anvaer, et al., 1978 
PackedSqualane67.627.Bogoslovsky, Anvaer, et al., 1978 
PackedSqualane27.623.Bogoslovsky, Anvaer, et al., 1978 
PackedSqualane49.626.Bogoslovsky, Anvaer, et al., 1978 
PackedSqualane67.628.Bogoslovsky, Anvaer, et al., 1978 
PackedSqualane27.621.Hively and Hinton, 1968He, Chromosorb P; Column length: 15. m; Column diameter: 0.25 mm
PackedSqualane49.624.Hively and Hinton, 1968He, Chromosorb P; Column length: 15. m; Column diameter: 0.25 mm
PackedSqualane67.627.Hively and Hinton, 1968He, Chromosorb P; Column length: 15. m; Column diameter: 0.25 mm

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryCarbowax 20M64.834.2Sojak, Ruman, et al., 198750. m/0.25 mm/0.25 μm, H2

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryPONA632.Zhang, Ding, et al., 200950. m/0.20 mm/0.50 μm, Nitrogen, 35. C @ 15. min, 2. K/min, 200. C @ 10. min

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Diez, Guillen, et al., 1990
Diez, M.A.; Guillen, M.D.; Blanco, C.G.; Bermejo, J., Chromatographic study of methylcyclopentadiene dimers and iso-dimers and determination of their boiling points, J. Chromatogr., 1990, 508, 363-374, https://doi.org/10.1016/S0021-9673(00)91279-2 . [all data]

Safina, Poznyak, et al., 1989
Safina, L.R.; Poznyak, T.I.; Lisitsyn, D.M.; Kiseleva, E.V.; Kovalev, G.I., Selective gas-chromatographic determination of trace unsaturated and aromatic-hydrocarbons in complex-mixtures, J. Appl. Chem. USSR (Engl. Transl.), 1989, 44, 5, 749-754. [all data]

Bermejo, Blanco, et al., 1987
Bermejo, J.; Blanco, C.G.; Diez, M.A.; Guillén, M.D., Kováts retention indices of selected mono and polycyclic olefins, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1987, 10, 8, 461-463, https://doi.org/10.1002/jhrc.1240100809 . [all data]

Sojak, Ruman, et al., 1987
Sojak, L.; Ruman, J.; Janak, J., Characterization of Monoalkylcyclopentadiens by Retention-Structure Correlation in Capillary Gas Chromatography, J. Chromatogr., 1987, 391, 79-87, https://doi.org/10.1016/S0021-9673(01)94306-7 . [all data]

Bajus, Veselý, et al., 1979
Bajus, M.; Veselý, V.; Leclercq, P.A.; Rijks, J.A., Steam cracking of hydrocarbons. 2. Pyrolysis of methylcyclohexane, Ind. Eng. Chem. Prod. Res. Dev., 1979, 18, 2, 135-142, https://doi.org/10.1021/i360070a012 . [all data]

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]

Zhang, Ding, et al., 2009
Zhang, X.; Ding, L.; Sun, Z.; Song, L.; Sun, T., Study on quantitative structure-retention relationships for hydrocarbons in FCC gasoline, Chromatographia, 2009, 70, 3/4, 511-518, https://doi.org/10.1365/s10337-009-1174-0 . [all data]


Notes

Go To: Top, Gas Chromatography, References