Sulfotep
- Formula: C8H20O5P2S2
- Molecular weight: 322.319
- IUPAC Standard InChIKey: XIUROWKZWPIAIB-UHFFFAOYSA-N
- CAS Registry Number: 3689-24-5
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Thiodiphosphoric acid ([(HO)2P(S)]2O), tetraethyl ester; Thiopyrophosphoric acid ([(HO)2PS]2O), tetraethyl ester; ASP 47; Bladafum; Bladafume; Dithiofos; Dithion; Dithione; Dithiophos; Dithiotep; Ethyl thiopyrophosphate ([(EtO)2PS]2O); E393; O,O,O,O-Tetraethyl Dithiopyrophosphate; Sulfotepp; Thiotepp; TEDP; TEDTP; Tetraethyl dithiopyrophosphate; O,O,O'O'-Tetraethyl dithiopyrophosphate; Bay-E-393; Bis(O,O-diethylphosphorothionic) anhydride; Bladafun; Di(thiophosphoric) acid, tetraethyl ester; Dithiodiphosphoric acid, tetraethyl ester; Dithiopyrophosphate de tetraethyle; Ethyl thiopyrophosphate; ENT 16,273; Lethalaire G-57; O,O,O,O-Tetraethyl-dithio-difosfaat; O,O,O,O-Tetraetil-ditio-pirofosfato; Pirofos; Plant dithio aerosol; Plantfume 103 smoke generator; Pyrophosphoric acid, tetraethyldithio-; Pyrophosphorodithioic acid, tetraethyl ester; Pyrophosphorodithioic acid, O,O,O,O-tetraethyl ester; Sulfatep; Tetraethyl dithionopyrophosphate; Thiopyrophosphoric acid, tetraethyl ester; Bayer-E 393; O,O,O,O-Tetraaethyl-dithionopyrophosphat; Rcra waste number P109; Tetraethyldithiodifosfat; Thiodiphosphoric acid tetraethyl ester; UN 1704; Fulex; NSC 66403; Dithiopyrophosphoric acid, tetraethyl ester
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
IR Spectrum
Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Gas Phase Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Notice: Concentration information is not available for this spectrum and, therefore, molar absorptivity values cannot be derived.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
View spectrum image in SVG format.
Download spectrum in JCAMP-DX format.
Owner | NIST Standard Reference Data Program Collection (C) 2018 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | NIST Mass Spectrometry Data Center |
State | gas |
Instrument | HP-GC/MS/IRD |
Mass spectrum (electron ionization)
Go To: Top, IR Spectrum, Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | ACCUSTANDARD Chemicals / NIST MS Data Center. |
NIST MS number | 125497 |
Gas Chromatography
Go To: Top, IR Spectrum, Mass spectrum (electron ionization), References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | OV-1 | 190. | 1651. | Erdmann, Rochholz, et al., 1992 | |
Capillary | OV-1 | 220. | 1664. | Erdmann, Rochholz, et al., 1992 |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | SLB-5MS | 1671. | Mondello, Casilli, et al., 2007 | 30. m/0.25 mm/0.25 μm, He, 2. K/min; Tstart: 70. C; Tend: 300. C |
Capillary | SLB-5MS | 1675. | Mondello, Casilli, et al., 2007 | 30. m/0.25 mm/0.25 μm, He, 2. K/min; Tstart: 70. C; Tend: 300. C |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | HP-5MS | 1704. | Hankemeier, Rozenbrand, et al., 1998 | Program: not specified |
Capillary | HP-5MS | 1707. | Hankemeier, Rozenbrand, et al., 1998 | Program: not specified |
References
Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Erdmann, Rochholz, et al., 1992
Erdmann, F.; Rochholz, G.; Schütz, H.,
Retention-indices on OV-1 of approximately 170 commonly used pesticides,
Mikrochim. Acta, 1992, 106, 3-6, 219-226, https://doi.org/10.1007/BF01242093
. [all data]
Mondello, Casilli, et al., 2007
Mondello, L.; Casilli, A.; Tranchida, P.Q.; Presti, M.L.; Dugo, P.; Dugo, G.,
Comprehensive gas chromatography coupled to mass spectrometry for the separation of pesticides in a very complex matrix,
Anal. Bioanal. Chem., 2007, 389, 6, 1755-1763, https://doi.org/10.1007/s00216-007-1412-y
. [all data]
Hankemeier, Rozenbrand, et al., 1998
Hankemeier, Th.; Rozenbrand, J.; Abhadur, M.; Vreuls, J.J.; Brinkman, U.A.Th.,
Data Correlation in On-Line Solid-Phase Extraction - Gas Chromatography - Atomic Emission / Mass Spectrometric Detection of Unknown Microcontaminants,
Chromatographia, 1998, 48, 3/4, 273-283, https://doi.org/10.1007/BF02467683
. [all data]
Notes
Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.