Oxirane, 2-ethyl-2-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Quantity Value Units Method Reference Comment
Tboil354.65KN/AFourneau and Tiffeneau, 1907Uncertainty assigned by TRC = 3. K

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Gas Chromatography

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-10170.633.Tarjan, Nyiredy, et al., 1989 
CapillaryOV-10180.634.Tarjan, Nyiredy, et al., 1989 
CapillaryOV-10190.634.Tarjan, Nyiredy, et al., 1989 
CapillaryOV-10170.633.3Boneva and Dimov, 1987100. m/0.27 mm/0.9 μm
CapillaryOV-10180.633.7Boneva and Dimov, 1987100. m/0.27 mm/0.9 μm
CapillaryOV-10190.634.0Boneva and Dimov, 1987100. m/0.27 mm/0.9 μm

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryMethyl Silicone646.Farkas, Héberger, et al., 2004Program: not specified

References

Go To: Top, Phase change data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Fourneau and Tiffeneau, 1907
Fourneau; Tiffeneau, C. R. Hebd. Seances Acad. Sci., 1907, 145, 437. [all data]

Tarjan, Nyiredy, et al., 1989
Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M., Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography, J. Chromatogr., 1989, 472, 1-92, https://doi.org/10.1016/S0021-9673(00)94099-8 . [all data]

Boneva and Dimov, 1987
Boneva, S.; Dimov, N., Gas chromatographic separation of C4-C5 epoxides on a glass capillary column coated with OV-101 methylsilicone, Chromatographia, 1987, 23, 10, 770-772, https://doi.org/10.1007/BF02312672 . [all data]

Farkas, Héberger, et al., 2004
Farkas, O.; Héberger, K.; Zenkevich, I.G., Quantitative structure-retention relationships. XIV. Prediction of gas chromatographic retention indices for saturated O-, N-, and S-heterocyclic compounds, Chemom. Intell. Lab. Syst., 2004, 72, 2, 173-184, https://doi.org/10.1016/j.chemolab.2004.01.012 . [all data]


Notes

Go To: Top, Phase change data, Gas Chromatography, References