Phloretic acid, 2TMS derivative
- Formula: C15H26O3Si2
- Molecular weight: 310.5361
- IUPAC Standard InChIKey: NTWRBVRZYOLGDK-UHFFFAOYSA-N
- CAS Registry Number: 27750-62-5
- Chemical structure:
This structure is also available as a 2d Mol file - Other names: Hydrocinnamic acid, p-(trimethylsiloxy)-, trimethylsilyl ester; Trimethylsilyl 3-(4-[(trimethylsilyl)oxy]phenyl)propanoate; 3-(4-Hydroxyphenyl)propionic acid, (2TMS); 3-(4-Hydroxyphenyl)propionic acid, trimethylsilyl ether, trimethylsilyl ester; 4-Hydroxyhydrocinnamic acid, bis-TMS; 4-Hydroxyphenylpropionic acid, di-TMS; Benzenepropanoic acid, 4-hydroxy, bis-TMS; Benzenepropanoic acid, 4-hydroxy, (2TMS); Propanoic acid, 3-(4-hydroxyphenyl), bis-TMS; 3-(4-Hydroxyphenyl)propionic acid, TMS; Benzenepropanoic acid, 4-trimethylsilyloxy, trimethylsilyl ester; Benzenepropanoic acid, 4-hydroxy, TMS; 4-Hydroxyhydrocinnamic acid, TMS; 4-Hydroxyphenylpropionic acid, TMS
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-1 | 1752. | Kraus and Spiteller, 1997 | 30. m/0.32 mm/0.10 μm, H2, 3. K/min; Tstart: 80. C; Tend: 280. C |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | PE-5 | 1763. | Isidorov and Vinogorova, 2003 | He, 5. K/min; Column length: 30. m; Column diameter: 0.25 mm; Tstart: 50. C; Tend: 250. C |
Packed | OV-1 | 1750. | Mattsson and Petersson, 1977 | N2, Supelcoport, 4. K/min; Column length: 2. m; Tstart: 80. C; Tend: 240. C |
Packed | OV-1 | 1755. | Butts, 1972 | He, Chromosorb W HP (80-100 mesh), 10. K/min; Column length: 2. m; Tstart: 100. C; Tend: 325. C |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | VF-5MS | 1750.1 | Tret'yakov, 2008 | 30. m/0.25 mm/0.25 μm, He; Program: Multi-step temperature program; T(initial)=60C; T(final)=270C |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | HP-5MS | 1762. | Lee, Yanamandra, et al., 2002 | 30. m/0.25 mm/0.25 μm, He, 70. C @ 3. min, 4. K/min, 280. C @ 3. min |
Capillary | HP-5MS | 1754. | Lee, Yanamandra, et al., 2002 | 30. m/0.25 mm/0.25 μm, He, 70. C @ 3. min, 4. K/min, 280. C @ 3. min |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Kraus and Spiteller, 1997
Kraus, C.; Spiteller, G.,
Comparison of phenolic compounds from galls and shoots of Picea glauca,
Phytochemistry, 1997, 44, 1, 59-67, https://doi.org/10.1016/S0031-9422(96)00388-3
. [all data]
Isidorov and Vinogorova, 2003
Isidorov, V.A.; Vinogorova, V.T.,
GC-MS analysis of compounds extracted from buds of Populus balsamifera and Populus nigra,
Z. Naturforsch. C:, 2003, 58, 355-360. [all data]
Mattsson and Petersson, 1977
Mattsson, M.; Petersson, G.,
Reference GLC Data for the Analysis of Phenolic Compounds as Trimethylsilyl Derivatives,
J. Chromatogr. Sci., 1977, 15, 12, 546-554, https://doi.org/10.1093/chromsci/15.12.546
. [all data]
Butts, 1972
Butts, W.C.,
Two-Column Gas Chromatography of Trimethylsilyl Derivatives of Biochemically Significant Compounds,
Anal. Biochemistry, 1972, 46, 1, 187-199, https://doi.org/10.1016/0003-2697(72)90411-3
. [all data]
Tret'yakov, 2008
Tret'yakov, K.V.,
Retention Data. NIST Mass Spectrometry Data Center., NIST Mass Spectrometry Data Center, 2008. [all data]
Lee, Yanamandra, et al., 2002
Lee, B.Y.; Yanamandra, K.; Thurmon, T.F.,
Quantitative estimation of organic analytes with a capillary column,
Am. Clin. Lab., 2002, May, 30-34. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.