1-Octanamine, N-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin Japan AIST/NIMC Database- Spectrum MS-IW-3847
NIST MS number 236482

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryApiezon LH + KF100.1088.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon LH + KF100.1088.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon LH + KF100.1088.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon LH + KF100.1089.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon LH + KF100.1089.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon LH + KF100.1090.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon LH + KF100.1090.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon L + KF100.1086.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon L + KF100.1087.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon L + KF100.1087.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon L + KF100.1088.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon L + KF100.1088.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon L + KF100.1088.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon L + KF100.1088.Samusenko, Svetlova, et al., 198630. m/0.25 mm/0.063 μm, He
CapillaryApiezon L + KF100.1087.Svetlova, Samusenko, et al., 198630. m/0.25 mm/0.06 μm
CapillaryApiezon L + KF100.1087.Svetlova, Samusenko, et al., 198630. m/0.25 mm/0.06 μm
CapillaryApiezon L + KF100.1088.Svetlova, Samusenko, et al., 198630. m/0.25 mm/0.06 μm
CapillaryApiezon L + KF100.1089.Svetlova, Samusenko, et al., 198630. m/0.25 mm/0.06 μm
CapillaryApiezon L + KF100.1090.Svetlova, Samusenko, et al., 198630. m/0.25 mm/0.06 μm
CapillaryApiezon L + KF100.1090.Svetlova, Samusenko, et al., 198630. m/0.25 mm/0.06 μm
PackedApiezon L100.1085.Golovnya, Zhuravleva, et al., 1980N2, Chromosorb GAW; Column length: 2.7 m

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryUltra-11085.Okumura, 199125. m/0.32 mm/0.25 μm, He, 3. K/min; Tstart: 80. C; Tend: 260. C

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Samusenko, Svetlova, et al., 1986
Samusenko, A.L.; Svetlova, N.I.; Golovnya, R.V., Reproducible and durable glass capillary columns with hydrogenated apiezon-l and OV-101 for the analysis of polar substances, Zh. Anal. Khim., 1986, 61, 1, 127-133. [all data]

Svetlova, Samusenko, et al., 1986
Svetlova, N.I.; Samusenko, A.L.; Golovnya, R.V., Advantage of the universal equation over the linear equation for the calculation of retention parameters of homologous series in capillary chromatography, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 12, 737-740, https://doi.org/10.1002/jhrc.1240091205 . [all data]

Golovnya, Zhuravleva, et al., 1980
Golovnya, R.V.; Zhuravleva, N.L.; Svetlova, N.I.; Grigor'eva, D.N., Gas-chromatographic separation of secondary normal alphatic amines, J. Anal. Chem. USSR (Engl. Transl.), 1980, 35, 10, 1280-1285. [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]


Notes

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References