Pyridine, 2-(1-methyl-2-pyrrolidinyl)-


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5MSDB-5DB-5DB-5SPB-1
Column length (m) 30.30.30.30.30.
Carrier gas HeH2H2H2He
Substrate      
Column diameter (mm) 0.250.320.320.320.75
Phase thickness (μm) 0.251.1.1.1.0
Tstart (C) 40.40.40.40.160.
Tend (C) 200.210.210.210.280.
Heat rate (K/min) 2.3.3.3.10.
Initial hold (min) 5.    
Final hold (min) 20.   12.
I 1339.1360.1381.1384.1354.
ReferenceKim, Shin, et al., 2001Moio, Piombino, et al., 2000Moio and Addeo, 1998Moio and Addeo, 1998Christ, Noomano, et al., 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase CBP-1DB-1Methyl Silicone5 % Phenyl methyl siloxaneDB-1
Column length (m) 12.15.12.12.15.
Carrier gas N2HeHeHeHe
Substrate      
Column diameter (mm) 0.530.320.20.20.25
Phase thickness (μm)  0.250.330.330.25
Tstart (C) 120.120.50.50.120.
Tend (C) 250.280.300.300.280.
Heat rate (K/min) 6.8.20.20.8.
Initial hold (min)   1.1. 
Final hold (min)  5.3.3.5.
I 1301.1326.1311.01346.01326.
ReferenceOyama, Sano, et al., 1987Perrigo, Peel, et al., 1985Newton and Foery, 1984Newton and Foery, 1984Perrigo, Ballantyne, et al., 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase DB-1DB-1DB-1SE-30SE-30
Column length (m) 15.15.15.15.1.8
Carrier gas HeHeHeHeN2
Substrate     Chromosorb W
Column diameter (mm) 0.250.250.250.25 
Phase thickness (μm) 0.250.250.250.25 
Tstart (C) 120.120.120.100.130.
Tend (C) 280.280.280.295.290.
Heat rate (K/min) 12.15.5.5.8.
Initial hold (min)     2.
Final hold (min) 5.5.5. 8.
I 1329.1330.1323.1315.1340.
ReferencePerrigo, Ballantyne, et al., 1984Perrigo, Ballantyne, et al., 1984Perrigo, Ballantyne, et al., 1984Anderson and Stafford, 1983Perrigo and Peel, 1981
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kim, Shin, et al., 2001
Kim, T.H.; Shin, J.H.; Baek, H.H.; Lee, H.J., Volatile flavour compounds in suspension culture of Agastache rugosa Kuntze (Korean mint), J. Sci. Food Agric., 2001, 81, 6, 569-575, https://doi.org/10.1002/jsfa.845 . [all data]

Moio, Piombino, et al., 2000
Moio, L.; Piombino, P.; Addeo, F., Odour-impact compounds of Gorgonzola cheese, J. Dairy Res., 2000, 67, 2, 273-285, https://doi.org/10.1017/S0022029900004106 . [all data]

Moio and Addeo, 1998
Moio, L.; Addeo, F., Grana Padano cheese aroma, J. Dairy Res., 1998, 65, 2, 317-333, https://doi.org/10.1017/S0022029997002768 . [all data]

Christ, Noomano, et al., 1988
Christ, D.W.; Noomano, P.; Rosas, M.; Rhone, D., Retention indices by wide-bore capillary gas chromatography with nitrogen-phosphorus detection, J. Anal. Toxicol., 1988, 12, 2, 84-88, https://doi.org/10.1093/jat/12.2.84 . [all data]

Oyama, Sano, et al., 1987
Oyama, N.; Sano, T.; Syoyama, M.; Maeda, K., Studies on systematic analysis of poisonous compounds in forensic chemistry. II. Application of capillary column gas chromatography to substance identification by means of retention indices, Eisei Kagaku, 1987, 33, 5, 342-348, https://doi.org/10.1248/jhs1956.33.342 . [all data]

Perrigo, Peel, et al., 1985
Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J., Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology., J. Chromatogr., 1985, 341, 81-88, https://doi.org/10.1016/S0378-4347(00)84011-6 . [all data]

Newton and Foery, 1984
Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 1984, 8, 3, 129-134, https://doi.org/10.1093/jat/8.3.129 . [all data]

Perrigo, Ballantyne, et al., 1984
Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 1984, 17, 2, 41-49, https://doi.org/10.1080/00085030.1984.10757360 . [all data]

Anderson and Stafford, 1983
Anderson, W.H.; Stafford, D.T., Applications of capillary gas chromatography in routine toxicological analyses, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1983, 6, 5, 247-254, https://doi.org/10.1002/jhrc.1240060506 . [all data]

Perrigo and Peel, 1981
Perrigo, B.J.; Peel, H.W., The use of retention indices and temperature-programmed gas chromatography in analytical toxicology, J. Chromatogr. Sci., 1981, 19, 5, 219-226, https://doi.org/10.1093/chromsci/19.5.219 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References