1,2-Dimethyl-3-isopropylbenzene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Quantity Value Units Method Reference Comment
Tboil477.7KN/AVolkov and Zavgorodnii, 1961Uncertainty assigned by TRC = 1. K

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Gas Chromatography

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-1120.1134.Protic, Svob, et al., 1980He; Column length: 40. m; Column diameter: 0.50 mm

Normal alkane RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryPEG-40M100.1454.Nesterov, Nesterova, et al., 2000Column length: 50. m
CapillaryPEG-40M100.1454.Nesterov, Nesterova, et al., 2000Column length: 50. m
CapillaryPEG-40M120.1467.Nesterov, Nesterova, et al., 2000Column length: 50. m
CapillaryPEG-40M140.1481.Nesterov, Nesterova, et al., 2000Column length: 50. m
CapillaryPEG-40M160.1496.Nesterov, Nesterova, et al., 2000Column length: 50. m
CapillaryPEG-40M80.1440.Nesterov, Nesterova, et al., 2000Column length: 50. m

References

Go To: Top, Phase change data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Volkov and Zavgorodnii, 1961
Volkov, R.N.; Zavgorodnii, S.V., Zh. Obshch. Khim., 1961, 31, 2629-35. [all data]

Protic, Svob, et al., 1980
Protic, G.; Svob, V.; Deur-Siftar, D., Mass spectrometric and gas chromatographic data in hydrocarbon analyse, Sci. Papers of the Prague Institute of Chem. Technol., 1980, D42, 139-147. [all data]

Nesterov, Nesterova, et al., 2000
Nesterov, I.A.; Nesterova, T.N.; Pimerzin, A.A.; Tsvetkov, V.S., Thermodynamics of alkylbenzene sorption and evaporation. IV. Enthalpies of evaporation and thermodynamics chracteristics of sorption by stationary phases OV-101 and PEG-40M, Izvestia vysshikh uchebnykh zavedenii. Khimia i khimicheskaia tekhnologia (Chemistry and chemical technology), 2000, 43, 4, 39-45. [all data]


Notes

Go To: Top, Phase change data, Gas Chromatography, References