(Z,Z)-3,6-Nonadienal


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin C.Milo ET.AL.J.Agric.Food Chem.,41,2076(1993)
NIST MS number 293062

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-51076.Methven L., Tsoukka M., et al., 200760. m/0.32 mm/1. μm, 40. C @ 2. min, 4. K/min, 260. C @ 10. min

Van Den Dool and Kratz RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillarySE-541098.Heiler and Schieberle, 1997Program: not specified

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-5MS1097.Lee, Suriyaphan, et al., 200160. m/0.25 mm/0.25 μm, He, 40. C @ 5. min, 2. K/min, 200. C @ 30. min
CapillarySE-541100.Milo and Grosch, 199630. m/0.52 mm/1.5 μm, 6. K/min; Tstart: 5. C; Tend: 230. C
CapillarySE-541100.Milo and Grosch, 199630. m/0.52 mm/1.5 μm, 6. K/min; Tstart: 5. C; Tend: 230. C
CapillaryRTX-51100.Milo and Grosch, 199530. m/0.52 mm/1.5 μm, He, 6. K/min; Tstart: 5. C; Tend: 230. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryRTX-11083.ChromTech Pty Ltd, 2006Program: not specified
CapillaryDB-51100.Staples E.S., 2002Program: not specified
CapillaryOV-1011083.Acree and Arn, 1997Program: not specified
CapillarySE-541100.Milo and Grosch, 1993He; Column length: 30. m; Column diameter: 0.32 mm; Program: 40 0C -> (unknowm rate) 50 0C (2 min) 6 0C/min -> 200 0C

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Methven L., Tsoukka M., et al., 2007
Methven L.; Tsoukka M.; Oruna-Concha M.J.; Parker J.K.; Mottram D.S., Influence of sulfur amino acids on the volatile and nonvolatile components of cooked salmon (Salmo salar), J. Agric. Food Chem., 2007, 55, 4, 1427-1436, https://doi.org/10.1021/jf0625611 . [all data]

Heiler and Schieberle, 1997
Heiler, C.; Schieberle, P., Model studies on the precursors and formation of the metallic smelling (E,Z)-2,6-nonadienol during the manufacture and storage of buttermilk, Int. Dairy J., 1997, 7, 10, 667-674, https://doi.org/10.1016/S0958-6946(97)00069-1 . [all data]

Lee, Suriyaphan, et al., 2001
Lee, G.-H.; Suriyaphan, O.; Cadwallader, K.R., Aroma components of cooked tail meat of American lobster (Homarus americanus), J. Agric. Food Chem., 2001, 49, 9, 4324-4332, https://doi.org/10.1021/jf001523t . [all data]

Milo and Grosch, 1996
Milo, C.; Grosch, W., Changes in the odorants of boiled salmon and cod as affected by the storage of the raw material, J. Agric. Food Chem., 1996, 44, 8, 2366-2371, https://doi.org/10.1021/jf9507203 . [all data]

Milo and Grosch, 1995
Milo, C.; Grosch, W., Detection of odor defects in boiled cod and trout by gas chromatography-olfactometry of headspace samples, J. Agric. Food Chem., 1995, 43, 2, 459-462, https://doi.org/10.1021/jf00050a038 . [all data]

ChromTech Pty Ltd, 2006
ChromTech Pty Ltd, Retention Data: Rtx-1, Rtx-5, Rtx-50, Rtx-Stab Kovats RI, 2006, retrieved from http://www.chromtech.net.au/pdf/RI-Flavors-20M.pdf. [all data]

Staples E.S., 2002
Staples E.S., The Chemistry of Black Tea Aroma, EST Internal Report, April, Electronic Sensor Technology, Newbury PAck, CA 91320, 2002, 16, retrieved from http://www.estcal.com/TechPapers/TeaSamples2.pdf. [all data]

Acree and Arn, 1997
Acree, T.; Arn, H., Cornell University Flavornet, 1997, retrieved from http://www.flavornet.org/flavornet.html. [all data]

Milo and Grosch, 1993
Milo, C.; Grosch, W., Changes in the odorants of boiled trout (Salmo fario) as affected by the storage of the raw material, J. Agric. Food Chem., 1993, 41, 11, 2076-2081, https://doi.org/10.1021/jf00035a048 . [all data]