aluminium hydroxide
- Formula: AlH3O3
- Molecular weight: 78.0036
- CAS Registry Number: 21645-51-2
- Information on this page:
- Data at other public NIST sites:
- Options:
Reaction thermochemistry data
Go To: Top, IR Spectrum, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: José A. Martinho Simões
Note: Please consider using the reaction search for this species. This page allows searching of all reactions involving this species. A general reaction search form is also available. Future versions of this site may rely on reaction search pages in place of the enumerated reaction displays seen below.
Individual Reactions
3 (g) + (l) = AlH3O3 (amorphous) + 3 (g)
By formula: 3H2O (g) + C6H15Al (l) = AlH3O3 (amorphous) + 3C2H6 (g)
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
ΔrH° | -647.3 ± 6.3 | kJ/mol | RSC | Fowell, 1961 | Please also see Cox and Pilcher, 1970. Liquid triethylaluminum contains a very small molar fraction of monomer at 298 K, ca. 0.1% Smith, 1967, so that the "real" liquid should be described as [Al(Et)3]2. |
IR Spectrum
Go To: Top, Reaction thermochemistry data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Timothy J. Johnson, Tanya L. Myers, Yin-Fong Su, Russell G. Tonkyn, Molly Rose K. Kelly-Gorham, and Tyler O. Danby
Condensed Phase Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
View spectrum image in SVG format.
Download spectrum in JCAMP-DX format.
Detailed documentation for this spectrum is available.
Particle size distribution data for this spectrum is available.
Owner | Public domain |
---|---|
Origin | Pacific Northwest National Laboratory Under IARPA Contract |
Date | March 2017 |
State | solid |
Instrument | Bruker Tensor 37 FTIR |
Aperture | 6 mm |
External diffuse reflectance accessory | A 562-G integrating sphere |
Beam splitter | Ge on KBr |
Diameter of detector port in sphere | 2×2 mm, 60° field of view MCT |
Sphere diameter | 75 mm |
Acquisition mode | double-sided, forward-backward |
Scanner velocity | 40 kHz |
Co-added scans | 2048 |
Phase resolution | 32.00 |
Phase correction | Mertz |
Zero filling | 4× |
Spectral range | 7,500 to 600 cm-1 saved; 7500 to 600 cm-1 reported |
Resolution | 0.96450084 |
Spectral resolution | 4 cm-1 |
Wavenumber accuracy | ± 0.4 cm-1 |
Apodization function | Blackman-Harris 3-term |
Low-pass filter | Open |
Switch gain on | 512 points |
References
Go To: Top, Reaction thermochemistry data, IR Spectrum, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Fowell, 1961
Fowell, P.A.,
Ph. D. Thesis, University of Manchester, 1961. [all data]
Cox and Pilcher, 1970
Cox, J.D.; Pilcher, G.,
Thermochemistry of Organic and Organometallic Compounds
in Academic Press, New York, 1970. [all data]
Smith, 1967
Smith, M.B.,
J. Phys. Chem., 1967, 71, 364. [all data]
Notes
Go To: Top, Reaction thermochemistry data, IR Spectrum, References
- Symbols used in this document:
ΔrH° Enthalpy of reaction at standard conditions - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.