Picene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedOV-101270.3159.Grimmer and Böhnke, 1976N2, Gas Chrom Q (100-120 mesh); Column length: 10. m
PackedOV-101270.3159.Grimmer and Böhnke, 1975Gas Chrom Q; Column length: 10. m

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillarySE-523140.Beernaert, 1979He, 50. C @ 5. min, 6. K/min; Column length: 33.3 m; Column diameter: 0.50 mm; Tend: 320. C
CapillarySE-523150.Carugno and Rossi, 1967N2, 1.8 K/min; Column length: 65. m; Column diameter: 0.3 mm; Tstart: 100. C; Tend: 300. C

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP-53177.Miao and Wu, 199930. m/0.32 mm/0.25 μm, 50. C @ 2. min, 5. K/min; Tend: 310. C
CapillaryHP-53179.Miao and Wu, 199930. m/0.32 mm/0.25 μm, 50. C @ 2. min, 5. K/min; Tend: 310. C
CapillaryHP-53213.Miao and Wu, 199930. m/0.32 mm/0.25 μm, 50. C @ 2. min, 5. K/min; Tend: 310. C
CapillaryHP-53214.Miao and Wu, 199930. m/0.32 mm/0.25 μm, 50. C @ 2. min, 5. K/min; Tend: 310. C
CapillaryHP-53227.Miao and Wu, 199930. m/0.32 mm/0.25 μm, 50. C @ 2. min, 5. K/min; Tend: 310. C
CapillaryHP-53227.Miao and Wu, 199930. m/0.32 mm/0.25 μm, 50. C @ 2. min, 5. K/min; Tend: 310. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
PackedOV-1013159.Kaliszan and Lamparczyk, 1978Program: not specified

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Grimmer and Böhnke, 1976
Grimmer, G.; Böhnke, H., Anreicherung und gas-chromatographische Profil-Analyse der polycyclischen aromatischen Kohlenwasserstoffe in Schmieröl, Chromatographia, 1976, 9, 1, 30-40, https://doi.org/10.1007/BF02270595 . [all data]

Grimmer and Böhnke, 1975
Grimmer, G.; Böhnke, H., Polycyclic aromatic hydrocarbon profile analysis of high-protein foods, oils, and fats by gas chromatography, J. Ass. Offic. Anal. Chem, 1975, 58, 4, 725-733. [all data]

Beernaert, 1979
Beernaert, H., Gas Chromatographic Analysis of Polyclylic Aromatic Hydrocarbons, J. Chromatogr., 1979, 173, 1, 109-118, https://doi.org/10.1016/S0021-9673(01)80450-7 . [all data]

Carugno and Rossi, 1967
Carugno, N.; Rossi, S., Evaluation of polynuclear hydrocarbons in cigarette smoke by glass capillary columns, J. Gas Chromatogr., 1967, 5, 2, 103-106, https://doi.org/10.1093/chromsci/5.2.103 . [all data]

Miao and Wu, 1999
Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 1999, 15, 4, 288-292. [all data]

Kaliszan and Lamparczyk, 1978
Kaliszan, R.; Lamparczyk, H., A Relationship between the Connectivity Indices and Retention Indices of Polycyclic Aromatic Hydrocarbons, J. Chromatogr. Sci., 1978, 16, 6, 246-248, https://doi.org/10.1093/chromsci/16.6.246 . [all data]


Notes

Go To: Top, Gas Chromatography, References