Cyclohexane, 2-propenyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
ALS - Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein
AC - William E. Acree, Jr., James S. Chickos

Quantity Value Units Method Reference Comment
Tboil400.23KN/AAnonymous, 1952Uncertainty assigned by TRC = 0.15 K; TRC
Tboil422.KN/AHurd and Bollman, 1933Uncertainty assigned by TRC = 4. K; TRC
Quantity Value Units Method Reference Comment
Δvap44.0 ± 0.3kJ/molCFuchs and Peacock, 1979ALS
Δvap44.0 ± 0.2kJ/molGCCFuchs and Peacock, 1979AC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Gas Chromatography

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-101100.926.Engewald, Topalova, et al., 1987Column length: 50. m; Column diameter: 0.30 mm
CapillaryOV-1100.925.9Anders, Anders, et al., 198555. m/0.21 mm/0.35 μm, N2
CapillarySE-30130.935.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-3080.919.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySqualane86.921.0Nabivach, Bur'yan, et al., 1978Column length: 50. m; Column diameter: 0.25 mm
CapillarySqualane96.922.5Nabivach, Bur'yan, et al., 1978Column length: 50. m; Column diameter: 0.25 mm

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillarySqualane919.Chen, 2008Program: not specified
CapillaryMethyl Silicone918.Zenkevich, 1996Program: not specified
CapillaryMethyl Silicone918.Zenkevich, 1995Program: not specified

References

Go To: Top, Phase change data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Anonymous, 1952
Anonymous, R., , Physical Properties of Chemical Substances, Dow Chemical Co., 1952. [all data]

Hurd and Bollman, 1933
Hurd, C.D.; Bollman, H.T., The Pyrolysis of Alpha Unsaturated Hydrocarbons, J. Am. Chem. Soc., 1933, 55, 699-702. [all data]

Fuchs and Peacock, 1979
Fuchs, R.; Peacock, L.A., Heats of vaporization and gaseous heats of formation of some five- and six-membered ring alkenes, Can. J. Chem., 1979, 57, 2302-2304. [all data]

Engewald, Topalova, et al., 1987
Engewald, W.; Topalova, I.; Petsev, N.; Dimitrov, Chr., Structure-Retention Correlations of Hydrocarbons in GLC and GSC. Alkenylbenzenes, Chromatographia, 1987, 23, 8, 561-565, https://doi.org/10.1007/BF02324864 . [all data]

Anders, Anders, et al., 1985
Anders, G.; Anders, K.; Engewald, W., Identification of non-branched alkenylcycloalkanes with a terminal double bond from retention index increments, Chromatographia, 1985, 20, 2, 83-86, https://doi.org/10.1007/BF02280602 . [all data]

Bredael, 1982
Bredael, P., Retention indices of hydrocarbons on SE-30, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1982, 5, 6, 325-328, https://doi.org/10.1002/jhrc.1240050610 . [all data]

Nabivach, Bur'yan, et al., 1978
Nabivach, V.M.; Bur'yan, P.; Matsak, I., Retention indices of aromatic hydrocarbons on a squalane capillary column, Zh. Anal. Khim., 1978, 33, 7, 1108-1113. [all data]

Chen, 2008
Chen, H.-F., Quantitative prediction of gas chromatography retention indices with support vector machines, radial basis neutral networks and multiple linear regression, Anal. Chim. Acta, 2008, 609, 1, 24-36, https://doi.org/10.1016/j.aca.2008.01.003 . [all data]

Zenkevich, 1996
Zenkevich, I.G., Informational Maitenance of Gas Chromatographic Identification of Organic Compounds in Ecoanalytical Investigations, Z. Anal. Chem., 1996, 51, 11, 1140-1148. [all data]

Zenkevich, 1995
Zenkevich, I.G., Calculation of Gas-Chromatographic Retention Indices from Physico-Chemical Constants of Organic Compounds, Z. Anal. Chem., 1995, 50, 10, 1048-1056. [all data]


Notes