Benzeneacetic acid, α-[(trimethylsilyl)oxy]-, trimethylsilyl ester
- Formula: C14H24O3Si2
- Molecular weight: 296.5096
- IUPAC Standard InChIKey: QGQNCTUAZAEYNK-UHFFFAOYSA-N
- CAS Registry Number: 2078-19-5
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Acetic acid, phenyl(trimethylsiloxy)-, trimethylsilyl ester; Mandelic acid (ditms); Trimethylsilyl-α-(trimethylsiloxy)phenylacetae; andelic acid, di(trimethylsilyl) deriv.; Trimethylsilyl phenyl[(trimethylsilyl)oxy]acetate; Mandelic acid, bis-TMS; Mandelic acid, TMS; Mandelic acid, 2TMS derivative; Mandelic acid, di(trimethylsilyl) deriv.; Mandelic acid, trimethylsilyl ether, trimethylsilyl ester; DL-Mandelic acid, trimethylsilyl ether, trimethylsilyl ester
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | OV-1 | 1473. | Lefevere, Verhaeghe, et al., 1989 | 10. m/0.22 mm/0.17 μm, He, 5. K/min; Tstart: 70. C; Tend: 270. C |
Capillary | SE-52 | 1491. | Lefevere, Verhaeghe, et al., 1989 | 25. m/0.32 mm/0.52 μm, He, 5. K/min; Tstart: 70. C; Tend: 270. C |
Capillary | CP Sil 5 CB | 1472. | Wurth, Kumps, et al., 1989 | N2, 60. C @ 0.5 min, 6. K/min, 280. C @ 5. min |
Capillary | SE-52 | 1491. | Lefevere, Verhaeghe, et al., 1988 | 25. m/0.20 mm/0.40 μm, He, 5. K/min; Tstart: 50. C; Tend: 270. C |
Capillary | Ultra-2 | 1491. | Tuchman, Bowers, et al., 1984 | 25. m/0.31 mm/0.52 μm, He, 5. K/min; Tstart: 50. C; Tend: 300. C |
Packed | OV-1 | 1470. | Mattsson and Petersson, 1977 | N2, Supelcoport, 4. K/min; Column length: 2. m; Tstart: 80. C; Tend: 240. C |
Packed | OV-1 | 1477. | Butts, 1972 | He, Chromosorb W HP (80-100 mesh), 10. K/min; Column length: 2. m; Tstart: 100. C; Tend: 325. C |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | VF-5MS | 1468.1 | Tret'yakov, 2008 | 30. m/0.25 mm/0.25 μm, He; Program: Multi-step temperature program; T(initial)=60C; T(final)=270C |
Capillary | DB-1 | 1473. | Tsai, Oliphant, et al., 1985 | He; Program: not specified |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | HP-5 | 1491. | Isidorov, Kotowska, et al., 2005 | 30. m/0.25 mm/0.25 μm, He; Tstart: 50. C; Tend: 300. C |
Capillary | HP-5 | 1489. | Isidorov, Kotowska, et al., 2005 | 30. m/0.25 mm/0.25 μm, He, 5. K/min; Tstart: 50. C; Tend: 300. C |
Capillary | HP-5MS | 1491. | Lee, Yanamandra, et al., 2002 | 30. m/0.25 mm/0.25 μm, He, 70. C @ 3. min, 4. K/min, 280. C @ 3. min |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Lefevere, Verhaeghe, et al., 1989
Lefevere, M.F.; Verhaeghe, B.J.; Declerck, D.H.; Van Bocxlaer, J.F.; De Leenheer, A.P.; De Sagher, R.M.,
Metabolic Profiling of Urinary Organic Acids by Single and Multicolumn Capillary Gas Chromatography,
J. Chromatogr. Sci., 1989, 27, 1, 23-29, https://doi.org/10.1093/chromsci/27.1.23
. [all data]
Wurth, Kumps, et al., 1989
Wurth, C.; Kumps, A.; Mardens, Y.,
Urinary organic acids: Retention indices on two capillary gas chromatography columns,
J. Chromatogr., 1989, 491, 186-192, https://doi.org/10.1016/S0378-4347(00)82831-5
. [all data]
Lefevere, Verhaeghe, et al., 1988
Lefevere, M.F.; Verhaeghe, B.J.; Declerck, D.M.; de Leenheer, A.P.,
Automated profiling of urinary organic acids by dual-column gas chromatography and gas chromatography/mass spectrometry,
Biomed. Environ. Mass Spectrom., 1988, 15, 6, 311-322, https://doi.org/10.1002/bms.1200150603
. [all data]
Tuchman, Bowers, et al., 1984
Tuchman, M.; Bowers, L.D.; Fregien, K.D.; Crippin, P.J.; Krivit, W.,
Capillary Gas Chromatographic Separation of Urinary Organic Acids. Retention Indices of 101 Urinary Acids on a 5% Phenylmethyl Silicone Capillary Column,
J. Chromatogr. Sci., 1984, 22, 5, 198-202, https://doi.org/10.1093/chromsci/22.5.198
. [all data]
Mattsson and Petersson, 1977
Mattsson, M.; Petersson, G.,
Reference GLC Data for the Analysis of Phenolic Compounds as Trimethylsilyl Derivatives,
J. Chromatogr. Sci., 1977, 15, 12, 546-554, https://doi.org/10.1093/chromsci/15.12.546
. [all data]
Butts, 1972
Butts, W.C.,
Two-Column Gas Chromatography of Trimethylsilyl Derivatives of Biochemically Significant Compounds,
Anal. Biochemistry, 1972, 46, 1, 187-199, https://doi.org/10.1016/0003-2697(72)90411-3
. [all data]
Tret'yakov, 2008
Tret'yakov, K.V.,
Retention Data. NIST Mass Spectrometry Data Center., NIST Mass Spectrometry Data Center, 2008. [all data]
Tsai, Oliphant, et al., 1985
Tsai, M.Y.; Oliphant, C.; Josephson, M.W.,
Identification of Metabolites Diagnostic for Organic Acidurias by Simultaneous Dual-Column Capillary Gas Chromatography,
J. Chromatogr., 1985, 341, 1-10, https://doi.org/10.1016/S0378-4347(00)84004-9
. [all data]
Isidorov, Kotowska, et al., 2005
Isidorov, V.A.; Kotowska, U.; Vinogorova, V.T.,
GC Identification of organic compounds based on partition coefficients of their TMS derivatives in a hexane-acetonitrile system and retention indices,
Anal. Sci., 2005, 21, 12, 1483-1489, https://doi.org/10.2116/analsci.21.1483
. [all data]
Lee, Yanamandra, et al., 2002
Lee, B.Y.; Yanamandra, K.; Thurmon, T.F.,
Quantitative estimation of organic analytes with a capillary column,
Am. Clin. Lab., 2002, May, 30-34. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.