NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillarySqualane70.812.5Soják, 2004H2
CapillarySqualane70.812.51Soják, 2004N2
CapillarySqualane70.812.59Soják, 2004N2
PackedC78, Branched paraffin130.809.9Dallos, Sisak, et al., 2000He; Column length: 3.3 m
PackedC78, Branched paraffin130.810.6Reddy, Dutoit, et al., 1992Chromosorb G HP; Column length: 3.3 m
CapillarySqualane80.811.Soják, Farkas, et al., 1991107. m/0.25 mm/0.40 μm, H2
CapillaryOV-101110.839.Kuningas, Rang, et al., 1990He; Column length: 50. m; Column diameter: 0.25 mm
CapillarySqualane50.813.6Welsch, Engewald, et al., 1978Column length: 80. m; Column diameter: 0.23 mm
CapillarySqualane100.811.Rang, Kuningas, et al., 1976N2; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane110.810.Rang, Kuningas, et al., 1976N2; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane120.810.Rang, Kuningas, et al., 1976N2; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane130.809.Rang, Kuningas, et al., 1976N2; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane90.811.Rang, Kuningas, et al., 1976N2; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane80.813.Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryPEG 4000110.998.Rang, Orav, et al., 1988 
CapillaryPEG 400060.1000.Rang, Orav, et al., 1988 
CapillaryPEG 400080.999.Rang, Orav, et al., 1988 
CapillaryPEG 400070.1011.6Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryPetrocol DH841.White, Hackett, et al., 1992100. m/0.25 mm/0.5 μm, He, 1. K/min; Tstart: 30. C; Tend: 220. C

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Soják, 2004
Soják, L., Separation and identification of isomeric hydrocarbons by capillary gas chromatography and hyphenated spectrometric techniques, Petroleum Coal, 2004, 46, 3, 1-35. [all data]

Dallos, Sisak, et al., 2000
Dallos, A.; Sisak, A.; Kulcsár, Z.; Kováts, E., Pair-wise interactions by gas chromatography VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A, 2000, 904, 2, 211-242, https://doi.org/10.1016/S0021-9673(00)00908-0 . [all data]

Reddy, Dutoit, et al., 1992
Reddy, K.S.; Dutoit, J.-Cl.; Kovats, E. sz., Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr., 1992, 609, 1-2, 229-259, https://doi.org/10.1016/0021-9673(92)80167-S . [all data]

Soják, Farkas, et al., 1991
Soják, L.; Farkas, P.; Ostrovský, I.; Janák, J.; Chrétien, J.R., Capillary gas chromatography of C5 - C13 branched alkynes on squalane and liquid crystal stationary phases, J. Chromatogr., 1991, 557, 241-253, https://doi.org/10.1016/S0021-9673(01)87136-3 . [all data]

Kuningas, Rang, et al., 1990
Kuningas, K.; Rang, S.; Kailas, T., Relationship between the structure and retention of n-alkenes and n-alkynes on silicone phases, J. Chromatogr., 1990, 520, 137-148, https://doi.org/10.1016/0021-9673(90)85094-C . [all data]

Welsch, Engewald, et al., 1978
Welsch, Th.; Engewald, W.; Berger, P., IX. Das gas-chromatographische Retentionsverhalten isomerer Octine and Octadiine, Chromatographia, 1978, 11, 1, 5-9, https://doi.org/10.1007/BF02262945 . [all data]

Rang, Kuningas, et al., 1976
Rang, S.; Kuningas, K.; Orav, A.; Eisen, O., Capillary gas chromatography of n-alkynes. I. Retention indices, J. Chromatogr., 1976, 119, 451-460, https://doi.org/10.1016/S0021-9673(00)86807-7 . [all data]

Orav and Eisen, 1972
Orav, A.; Eisen, O., The retention indexes for alkenes, alkynes and cyclenes on capillary columns, Izv. Akad. Nauk Est. SSR, Khim. Geol., 1972, 21, 1, 39-47. [all data]

Rang, Orav, et al., 1988
Rang, S.A.; Orav, A.E.; Kuningas, K.R.; Meister, A.E.; Strense, T.V.; Eisen, O.G., Gas-Chromatographic Characteristics of unsaturated hydrocarbons, Academy of Sciences of Estonia SSR, Tallinn, Estonia SSR, 1988, 208. [all data]

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]


Notes

Go To: Top, Gas Chromatography, References