Androstan-3-ol, (3β,5α)-, TMS derivative


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin Philip J. Marriott, Australian Centre for Research on Separation Science, Melbourne, Australia
NIST MS number 372663

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-1175.2275.Brooks, Cole, et al., 198325. m/0.25 mm/0.25 μm
CapillaryOV-1200.2295.Brooks, Cole, et al., 198325. m/0.25 mm/0.25 μm

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-12285.Brooks, Cole, et al., 198325. m/0.25 mm/0.25 μm; Program: 80 0C (5 min) 40 K/min -> 120 0C (2 min) 2 K/min -> 200 0C (for androstanes), or 80 0C (5 min) 40 K/min -> 190 0C (2 min) 2 K/min -> 270 0C (for sterols)

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Brooks, Cole, et al., 1983
Brooks, C.J.W.; Cole, W.J.; Lawrie, T.D.V.; MacLachlan, J.; Borthwick, J.H.; Barrett, G.M., Selective reactions in the analytical characterisation of steroids by gas chromatography-mass spectrometry, J. Steroid Biochem., 1983, 19, 1, 189-201, https://doi.org/10.1016/S0022-4731(83)80025-9 . [all data]


Notes

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References