Cholesterol, TMS derivative
- Formula: C30H54OSi
- Molecular weight: 458.8347
- IUPAC Standard InChIKey: CBVJJGRSRFXUPK-SZXIZBHISA-N
- CAS Registry Number: 1856-05-9
- Chemical structure:
This structure is also available as a 2d Mol file - Other names: Cholesterol trimethylsilyl ether; Silane, [[(3β)-cholest-5-en-3-yl]oxy]trimethyl-; Silane, (cholesteryloxy)trimethyl-; O-Trimethylsilylcholesterol; 3β-(Trimethylsiloxy)cholest-5-ene; Cholest-5-ene, 3-[(trimethylsilyl)oxy]-, (3β)-; Monotrimethylsilyl derivative of cholesterol; 3-[(Trimethylsilyl)oxy]cholest-5-ene-, 3.beta-; 5-Cholesten-3-β-ol, TMS; Cholesterol, TMS; Cholesterol, mono-TMS; Cholest-5-en-3β-ol-, TMS; 5A-Cholesten-3-one, TMS; Epicholesterol TMS; Cholesterol (cholest-5-en-3β-ol), TMS; 3β-hydroxy-5-cholestene, TMS; [[(3β)-cholest-5-en-3-yl]oxy]trimethylsilane
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Packed | OV-1 | 260. | 3136. | Quilliam and Westmore, 1978 | Gas Chrom Q; Column length: 1. m |
Capillary | OV-1 | 255. | 3124. | Luyten and Rutten, 1974 | He; Column length: 20. m; Column diameter: 0.25 mm |
Kovats' RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | Methyl Silicone | 3143. | Shoda, Axelson, et al., 1993 | 25. m/0.32 mm/0.25 μm, 30. K/min; Tstart: 60. C; Tend: 290. C |
Kovats' RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | SE-30 | 3135. | Axelson, Mörk, et al., 1991 | 30. m/0.32 mm/0.25 μm; Program: 50C(6min) => rapidly => 190C => 5C/min => 285C |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5MS | 3144.9 | Jonsson, Johansson, et al., 2005 | 10. m/0.18 mm/0.18 μm, 70. C @ 2. min, 40. K/min, 320. C @ 2. min |
Capillary | OV-1 | 3120. | Luyten and Rutten, 1974 | He, 1. K/min; Column length: 20. m; Column diameter: 0.25 mm; Tstart: 220. C |
Capillary | SE-30 | 3122. | Luyten and Rutten, 1974 | He, 1. K/min; Column length: 20. m; Column diameter: 0.25 mm; Tstart: 200. C |
Packed | SE-30 | 3101. | Luyten and Rutten, 1974 | He, 1. K/min; Column length: 20. m; Column diameter: 0.25 mm; Tstart: 180. C |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | RTX-5 Sil MS | 3155. | Lytovchenko, Beleggia, et al., 2009 | 30. m/0.25 mm/0.25 μm, Helium, 70. C @ 5. min, 5. K/min, 310. C @ 1. min |
Capillary | Methyl Silicone | 3132. | Ichimiya, Egestad, et al., 1991 | 25. m/0.32 mm/0.25 μm, He, 25. K/min; Tstart: 80. C; Tend: 280. C |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | Ultra-1 | 3110. | Axelson, Ellis, et al., 2000 | 25. m/0.32 mm/0.17 μm, H2; Program: 50 0C (3 min) -> 185 0C 5 K/min -> 280 0C |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Quilliam and Westmore, 1978
Quilliam, M.A.; Westmore, J.B.,
Sterically crowded trialkylsilyl derivatives for chromatography and mass spectrometry of biologically-important compounds,
Anal. Chem., 1978, 50, 1, 59-68, https://doi.org/10.1021/ac50023a020
. [all data]
Luyten and Rutten, 1974
Luyten, J.A.; Rutten, G.A.F.M.,
Analysis of Steroids by High-Resolution Gas-Liquid Chromatography. II. Application to Urinary Samples,
J. Chromatogr., 1974, 91, 393-406, https://doi.org/10.1016/S0021-9673(01)97918-X
. [all data]
Shoda, Axelson, et al., 1993
Shoda, J.; Axelson, M.; Sjövall, J.,
Synthesis of potential C27-intermediates in bile acid biosynthesis and their deuterium-labeled analogs,
Steroids, 1993, 58, 3, 119-125, https://doi.org/10.1016/0039-128X(93)90048-R
. [all data]
Axelson, Mörk, et al., 1991
Axelson, M.; Mörk, B.; Everson, G.T.,
Bile Acid Synthesis in Cultured Human Hepatoblastoma Cells,
J. Biol. Chem., 1991, 266, 27, 17770-17777. [all data]
Jonsson, Johansson, et al., 2005
Jonsson, P.; Johansson, A.I.; Gullberg, J.; Trygg, J.; Jiye, A.; Grung, B.; Marklund, S.; Sjöström, M.; Antti, H.; Moritz, T.,
High-throughput data analysis for detecting and identifying differences between samples in GC/MS-based metabolomic analyses,
Anal. Chem., 2005, 77, 17, 5635-5642, https://doi.org/10.1021/ac050601e
. [all data]
Lytovchenko, Beleggia, et al., 2009
Lytovchenko, A.; Beleggia, R.; Schauer, N.; Isaacson, T.; Leuendorf, J.E.; Hellmann, H.; Rose, J.K.C.; Fernie, A.R.,
Application of GC-MS fpr the detection of lipophilic compounds in diverse plant tissues,
Plant Methods, 2009, 5, 4, 1-11. [all data]
Ichimiya, Egestad, et al., 1991
Ichimiya, H.; Egestad, B.; Nazer, H.; Baginski, E.S.; Clayton, P.T.; Sjövall, J.,
Bile acids and bile alcohols in a child with hepatic 3β-hydroxy-Δ5-C27-steroid dehydrogenase deficiency: effects of chenodeoxycholic acid treatment,
J. Lipid Res., 1991, 32, 829-841. [all data]
Axelson, Ellis, et al., 2000
Axelson, M.; Ellis, E.; Mörk, B.; Garmark, K.; Abrahamsson, A.; Björkhem, I.; Ericzon, B.-G.; Einarsson, C.,
Bile acid synthesis in cultured human hepatocytes: support for an alternative biosynthetic pathway to cholic acid,
Hepatology, 2000, 31, 6, 1305-1312, https://doi.org/10.1053/jhep.2000.7877
. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.