TATP

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-51105.8Barreto, Cañizo, et al., 200630. m/0.32 mm/0.25 μm, N2, 60. C @ 5. min, 10. K/min; Tend: 300. C
CapillaryDB-51125.8Barreto, Cañizo, et al., 200630. m/0.32 mm/0.25 μm, N2, 60. C @ 5. min, 20. K/min; Tend: 300. C
CapillaryDB-51115.3Barreto, Cañizo, et al., 200630. m/0.32 mm/0.25 μm, N2, 60. C @ 5. min, 5. K/min; Tend: 300. C
CapillaryRTX-5 MS1122.6Barreto, Cañizo, et al., 200630. m/0.25 mm/0.25 μm, He, 60. C @ 5. min, 10. K/min; Tend: 300. C
CapillaryRTX-5 MS1128.1Barreto, Cañizo, et al., 200630. m/0.25 mm/0.25 μm, He, 60. C @ 5. min, 20. K/min; Tend: 300. C
CapillaryRTX-5 MS1120.6Barreto, Cañizo, et al., 200630. m/0.25 mm/0.25 μm, He, 60. C @ 5. min, 5. K/min; Tend: 300. C
CapillaryRTX-5 MS1111.9Barreto, Cañizo, et al., 200630. m/0.25 mm/0.25 μm, He, 10. K/min; Tstart: 60. C; Tend: 300. C

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryZB-11094.Harvey and Wenzel, 200915. m/0.25 mm/0.10 μm, Helium, 4. K/min, 185. C @ 15. min; Tstart: 35. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-51115.Staples, 2004He; Program: not specified

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Barreto, Cañizo, et al., 2006
Barreto, G.P.; Cañizo, A.I.; Eyler, G.N., Use of Retention Data as the First Step in the Identification of Cyclic Organic Peroxides in Temperature-Programmed Gas Chromatography, Chromatographia, 2006, 63, 5-6, 261-266, https://doi.org/10.1365/s10337-006-0716-y . [all data]

Harvey and Wenzel, 2009
Harvey, S.D.; Wenzel, T.J., Selective retention of explosives and related compounds on gas-chromatographic capillary columns coated with lanthanide(III) beta-diketonate polymers, J. Chromatogr. A, 2009, 1216, 36, 6417-6423, https://doi.org/10.1016/j.chroma.2009.07.008 . [all data]

Staples, 2004
Staples, E.J., Analysis of odors from explosives using an electronic nose, 2004, retrieved from http://www.estcal.com/TechPapers/OdorsofExplosives.doc. [all data]