Bromoxynil
- Formula: C7H3Br2NO
- Molecular weight: 276.913
- IUPAC Standard InChIKey: UPMXNNIRAGDFEH-UHFFFAOYSA-N
- CAS Registry Number: 1689-84-5
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Benzonitrile, 3,5-dibromo-4-hydroxy-; Brominal; Broxynil; Buctril; 2,6-Dibromo-4-cyanophenol; 3,5-Dibromo-4-hydroxybenzonitrile; Brittox; Brominex; Brominil; Bucril; Buctril industrial; Butilchlorofos; Chipco buctril; Chipco crab-kleen; 3,5-Dibromo-4-hydroxyphenylcyanide; ENT 20852; 4-Hydroxy-3,5-dibromobenzonitrile; MB 10064; M&B 10,064; M&B 10731; ME4 Brominal; Nu-lawn weeder; Oxytril M; Torch; Labuctril; 4-Cyano-2,6-dibromophenol; Labuctril 25; Bromotril; Certrol B; Litarol M; Pardner; Sabre; S 2132; Toplan
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Condensed phase thermochemistry data
Go To: Top, Phase change data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
ΔfH°solid | Ccb | Zavoianu, Ciocazanu, et al., 1988 | uncertain value: -207.8 kJ/mol; Data origin uncertain | ||
Quantity | Value | Units | Method | Reference | Comment |
ΔcH°solid | -3131. | kJ/mol | Ccb | Zavoianu, Ciocazanu, et al., 1988 | Data origin uncertain |
Phase change data
Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
AC - William E. Acree, Jr., James S. Chickos
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
Tfus | 464.20 | K | N/A | Donnelly, Drewes, et al., 1990 | Uncertainty assigned by TRC = 0.2 K; TRC |
Tfus | 463.6 | K | N/A | Plato, 1972 | Uncertainty assigned by TRC = 0.2 K; TRC |
Enthalpy of fusion
ΔfusH (kJ/mol) | Temperature (K) | Method | Reference | Comment |
---|---|---|---|---|
32.03 | 464. | DSC | Donnelly, Drewes, et al., 1990, 2 | AC |
IR Spectrum
Go To: Top, Condensed phase thermochemistry data, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Timothy J. Johnson, Tanya L. Myers, Yin-Fong Su, Russell G. Tonkyn, Molly Rose K. Kelly-Gorham, and Tyler O. Danby
Condensed Phase Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
View spectrum image in SVG format.
Download spectrum in JCAMP-DX format.
Detailed documentation for this spectrum is available.
Particle size distribution data for this spectrum is available.
Owner | Public domain |
---|---|
Origin | Pacific Northwest National Laboratory Under IARPA Contract |
Date | March 2017 |
State | solid |
Instrument | Bruker IR Cube FTIR |
Aperture | Open |
External diffuse reflectance accessory | A 562-G integrating sphere |
Beam splitter | Ge on KBr |
Diameter of detector port in sphere | 2×2 mm, 60° field of view MCT |
Sphere diameter | 75 mm |
Acquisition mode | double-sided, forward-backward |
Scanner velocity | 40 kHz |
Co-added scans | 4096 |
Phase resolution | 32.00 |
Phase correction | Mertz |
Zero filling | 4× |
Spectral range | 7,500 to 600 cm-1 saved; 7500 to 600 cm-1 reported |
Resolution | 0.96450084 |
Spectral resolution | 4 cm-1 |
Wavenumber accuracy | ± 0.4 cm-1 |
Apodization function | Blackman-Harris 3-term |
Low-pass filter | Open |
Switch gain on | 512 points |
Mass spectrum (electron ionization)
Go To: Top, Condensed phase thermochemistry data, Phase change data, IR Spectrum, Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | MASS SPECTROMETRY CENTER, UNIV. OF UTAH EPA-PTSEL 0820 |
NIST MS number | 52630 |
Gas Chromatography
Go To: Top, Condensed phase thermochemistry data, Phase change data, IR Spectrum, Mass spectrum (electron ionization), References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | OV-1 | 190. | 1652. | Erdmann, Rochholz, et al., 1992 | |
Capillary | OV-1 | 220. | 1686. | Erdmann, Rochholz, et al., 1992 |
References
Go To: Top, Condensed phase thermochemistry data, Phase change data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Zavoianu, Ciocazanu, et al., 1988
Zavoianu, D.; Ciocazanu, I.; Moga-Gheorghe, S.; Bornaz, C.,
Structure and reactivity of nitriles. Heat of combustion and formation of some benzonitrile derivatives,
Rev. Chim. (Bucharest), 1988, 39, 487-489. [all data]
Donnelly, Drewes, et al., 1990
Donnelly, J.R.; Drewes, L.A.; Johnson, R.L.; Munslow, W.D.; Knapp, K.K.; Sovocool, G.W.,
Purity and heat of fusion data for environmental standards as determined by differential scanning calorimetry,
Thermochim. Acta, 1990, 167, 2, 155, https://doi.org/10.1016/0040-6031(90)80476-F
. [all data]
Plato, 1972
Plato, C.,
DSC as a general method for determining purity and heat of fusion of high-purity organic chemicals,
Anal. Chem., 1972, 44, 1531. [all data]
Donnelly, Drewes, et al., 1990, 2
Donnelly, J.R.; Drewes, L.A.; Johnson, R.L.; Munslow, W.D.; Knapp, K.K.; Sovocool, G.W.,
Purity and heat of fusion data for environmental standards as determined by differential scanning calorimetry,
Thermochimica Acta, 1990, 167, 2, 155-187, https://doi.org/10.1016/0040-6031(90)80476-F
. [all data]
Erdmann, Rochholz, et al., 1992
Erdmann, F.; Rochholz, G.; Schütz, H.,
Retention-indices on OV-1 of approximately 170 commonly used pesticides,
Mikrochim. Acta, 1992, 106, 3-6, 219-226, https://doi.org/10.1007/BF01242093
. [all data]
Notes
Go To: Top, Condensed phase thermochemistry data, Phase change data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References
- Symbols used in this document:
Tfus Fusion (melting) point ΔcH°solid Enthalpy of combustion of solid at standard conditions ΔfH°solid Enthalpy of formation of solid at standard conditions ΔfusH Enthalpy of fusion - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.