D-Glucitol, 6TMS derivative
- Formula: C24H62O6Si6
- Molecular weight: 615.2585
- IUPAC Standard InChIKey: USBJDBWAPKNPCK-UEQSERJNSA-N
- CAS Registry Number: 14199-80-5
- Chemical structure:
This structure is also available as a 2d Mol file - Stereoisomers:
- Other names: Trimethylsilyl ether of glucitol; d-Glucitol, 1,2,3,4,5,6-hexakis-O-(trimethylsilyl)-; Glucitol, hexakis-O-(trimethylsilyl)-, d-; 1,2,3,4,5,6-Hexakis-O-(trimethylsilyl)glucitol; D-Glucitol, hexakis-TMS; Glucitol, hexakis-TMS; Sorbitol, hexakis-O-(trimethylsilyl)-ether; Sorbitol, (6TMS); Sorbitol, TMS; Glucitol, TMS; D-Glucitol, TMS; D-Sorbitol (Glucitol), TMS
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | OV-101 | 200. | 2000.1 | Adam, 1981 | Column length: 50. m |
Kovats' RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5MS | 1981. | Medeiros and Simoneit, 2007 | 30. m/0.25 mm/0.25 μm, He, 65. C @ 2. min, 6. K/min, 300. C @ 15. min |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5MS | 1935.1 | Jonsson, Johansson, et al., 2005 | 10. m/0.18 mm/0.18 μm, 70. C @ 2. min, 40. K/min, 320. C @ 2. min |
Capillary | RTX-5Sil | 1931.1 | Wagner, Sefkow, et al., 2003 | 80. C @ 2. min, 18. K/min, 350. C @ 2. min; Column length: 30. m; Column diameter: 0.25 mm |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | HP-5 | 1982. | Madaj, Wisniewski, et al., 1993 | H2; Column length: 50. m; Column diameter: 0.20 mm; Program: 115 0C 3 0C/min -> 180 0C 4 0C/min -> 250 0C |
Normal alkane RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | OV-101 | 175. | 2005. | Zegota, 1980 | Column length: 50. m; Column diameter: 0.30 mm |
Capillary | SE-30 | 165. | 2020. | Zegota, 1980 | 35; Column diameter: 0.30 mm |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | HP-5 | 1979. | Isidorov, Lech, et al., 2008 | 30. m/0.25 mm/0.25 μm, Helium, 3. K/min, 300. C @ 30. min; Tstart: 50. C |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | HP-5 | 1982. | Isidorov, Lech, et al., 2008 | 30. m/0.25 mm/0.25 μm, Helium; Program: not specified |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Adam, 1981
Adam, S.,
Separation of mono- and di-saccharide derivatives by high-resolution gas chromatography,
Z. Lebensm. Unters. Forsch., 1981, 173, 2, 109-112, https://doi.org/10.1007/BF01042273
. [all data]
Medeiros and Simoneit, 2007
Medeiros, P.M.; Simoneit, B.R.T.,
Analysis of sugars in environmental samples by gas chromatography-mass spectrometry,
J. Chromatogr. A, 2007, 1141, 2, 271-278, https://doi.org/10.1016/j.chroma.2006.12.017
. [all data]
Jonsson, Johansson, et al., 2005
Jonsson, P.; Johansson, A.I.; Gullberg, J.; Trygg, J.; Jiye, A.; Grung, B.; Marklund, S.; Sjöström, M.; Antti, H.; Moritz, T.,
High-throughput data analysis for detecting and identifying differences between samples in GC/MS-based metabolomic analyses,
Anal. Chem., 2005, 77, 17, 5635-5642, https://doi.org/10.1021/ac050601e
. [all data]
Wagner, Sefkow, et al., 2003
Wagner, C.; Sefkow, M.; Kopka, J.,
Construction and application of a mass spectral and retention time index database generated from plant GC/EI-TOF-MS metabolite profiles,
Phytochemistry, 2003, 62, 6, 887-900, https://doi.org/10.1016/S0031-9422(02)00703-3
. [all data]
Madaj, Wisniewski, et al., 1993
Madaj, J.; Wisniewski, A.; Skorupowa, E.; Sokolowski, J.,
Capillary gas chromatographic separations of a multicomponent mixture of polyalcohol compounds,
J. Chromatogr. A, 1993, 655, 2, 267-273, https://doi.org/10.1016/0021-9673(93)83232-H
. [all data]
Zegota, 1980
Zegota, H.,
Separation and quantitative determination of fructose as the O-methyloxime by gas-liquid chromatography using glass capillary columns,
J. Chromatogr., 1980, 192, 2, 446-451, https://doi.org/10.1016/S0021-9673(80)80024-0
. [all data]
Isidorov, Lech, et al., 2008
Isidorov, V.A.; Lech, P.; Zolciak, A.; Rusak, N.; Szczepaniak, L.,
Gas Chromatographic - nass spectrometric investigation of metabolites from the needles and roots of pine seedlings at early stages of pathogenic fungi Armillaria ostoyae attack,
Trees, 2008, 22, 4, 531-542, https://doi.org/10.1007/s00468-008-0213-z
. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.