1-Pentadecene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryPackedCapillaryCapillaryCapillary
Active phase DB-1SE-30ApolaneApolaneApiezon L
Column length (m) 10.3.200.250.250.
Carrier gas HeArN2N2 or H2N2 or H2
Substrate  Gas Chrom Q (80-100 mesh)   
Column diameter (mm) 0.25 0.250.250.25
Phase thickness (μm) 0.25    
Temperature (C) 140.150.130.160.154.
I 1488.1490.1485.41486.71488.
ReferenceBeens, Tijssen, et al., 1998Tiess, 1984Soják, Krupcík, et al., 1980Soják, Krupcík, et al., 1980, 2Soják, Krupcík, et al., 1980, 2
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Apiezon LApiezon LApiezon LApiezon LSqualane
Column length (m) 250.250.250.250. 
Carrier gas N2 or H2N2 or H2N2 or H2N2 or H2 
Substrate      
Column diameter (mm) 0.250.250.250.25 
Phase thickness (μm)      
Temperature (C) 164.164.164.164.130.
I 1488.01488.21488.81491.31484.
ReferenceSoják, Krupcík, et al., 1980, 2Soják, Krupcík, et al., 1980, 2Soják, Krupcík, et al., 1980, 2Soják, Krupcík, et al., 1980, 2Soják, Hrivnák, et al., 1974
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase Squalane
Column length (m)  
Carrier gas  
Substrate  
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 130.
I 1485.
ReferenceSoják, Hrivnák, et al., 1974
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Beens, Tijssen, et al., 1998
Beens, J.; Tijssen, R.; Blomberg, J., Prediction of comprehensive two-dimensional gas chromatographic separations. A theoretical and practical exercise, J. Chromatogr. A, 1998, 822, 2, 233-251, https://doi.org/10.1016/S0021-9673(98)00649-9 . [all data]

Tiess, 1984
Tiess, D., Gaschromatographische Retentionsindices von 125 leicht- bis mittelflüchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30, Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 1984, 33, 6-9. [all data]

Soják, Krupcík, et al., 1980
Soják, L.; Krupcík, J.; Janák, J., Comparison of capillary columns coated with C87 hydrocarbon and squalane in the analysis of n-pentadecene isomers, J. Chromatogr., 1980, 191, 199-206, https://doi.org/10.1016/S0021-9673(00)86380-3 . [all data]

Soják, Krupcík, et al., 1980, 2
Soják, L.; Krupcík, J.; Janák, J., Gas chromatography of all C15-C18 linear alkenes on capillary columns with very high resolution power, J. Chromatogr., 1980, 195, 1, 43-64, https://doi.org/10.1016/S0021-9673(00)81542-3 . [all data]

Soják, Hrivnák, et al., 1974
Soják, L.; Hrivnák, J.; Ostrovský, I.; Janák, J., Capillary Gas Chromatography of Linear Alkenes on Squalane. Separation and Identification of n-Pentadecenes and n-Hexadecenes, J. Chromatogr., 1974, 91, 613-622, https://doi.org/10.1016/S0021-9673(01)97942-7 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References