beryllium hydroxide


Gas phase thermochemistry data

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Quantity Value Units Method Reference Comment
Δfgas-161.70kcal/molReviewChase, 1998Data last reviewed in December, 1975
Quantity Value Units Method Reference Comment
gas,1 bar55.918cal/mol*KReviewChase, 1998Data last reviewed in December, 1975

Gas Phase Heat Capacity (Shomate Equation)

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (cal/mol*K)
    H° = standard enthalpy (kcal/mol)
    S° = standard entropy (cal/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

View table.

Temperature (K) 298. to 1400.1400. to 6000.
A 15.0349023.05470
B 13.086801.817420
C -7.753892-0.328610
D 2.0035710.020866
E -0.280634-3.011760
F -167.6420-174.6640
G 68.9580175.87679
H -161.7000-161.7000
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in December, 1975 Data last reviewed in December, 1975

References

Go To: Top, Gas phase thermochemistry data, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas phase thermochemistry data, References