Rutile (TiO2)


Solid Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. to 2000.
A 67.29830
B 18.70940
C -11.57900
D 2.449561
E -1.485471
F -964.5140
G 117.8630
H -938.7220
ReferenceChase, 1998
Comment rutile phase; Data last reviewed in December, 1973
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.55.1849.8349.90-0.02
300.55.4350.2049.900.09
400.63.8067.4552.186.11
500.68.1282.2056.7512.72
600.70.7694.8762.0719.68
700.72.53105.967.5626.85
800.73.79115.772.9834.17
900.74.71124.478.2241.59
1000.75.39132.383.2449.10
1100.75.90139.688.0456.67
1200.76.28146.292.6164.27
1300.76.55152.396.9771.92
1400.76.76158.0101.179.58
1500.76.92163.3105.187.27
1600.77.04168.2108.994.97
1700.77.16172.9112.5102.7
1800.77.29177.3116.0110.4
1900.77.44181.5119.3118.1
2000.77.63185.5122.5125.9

References

Go To: Top, Solid Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Solid Phase Heat Capacity (Shomate Equation), References