9,10-Anthracenedione, 2-chloro-
- Formula: C14H7ClO2
- Molecular weight: 242.657
- IUPAC Standard InChIKey: FPKCTSIVDAWGFA-UHFFFAOYSA-N
- CAS Registry Number: 131-09-9
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Anthraquinone, 2-chloro-; β-Chloroanthraquinone; 2-Chloro-9,10-anthraquinone; 2-Chloroanthraquinone; 2-Chloro-9,10-anthracenedione
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Options:
Phase change data
Go To: Top, Mass spectrum (electron ionization), UV/Visible spectrum, Gas Chromatography, NIST Subscription Links, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
DH - Eugene S. Domalski and Elizabeth D. Hearing
AC - William E. Acree, Jr., James S. Chickos
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
Tfus | 483.15 | K | N/A | Anonymous, 1988 | Uncertainty assigned by TRC = 1. K; nominal value, from the catalog; TRC |
Tfus | 483.55 | K | N/A | Marsh, 1987 | Uncertainty assigned by TRC = 0.4 K; recommended as fixed point for thermometry; TRC |
Tfus | 482.85 | K | N/A | Witschonke, 1954 | Uncertainty assigned by TRC = 0.3 K; TRC |
Tfus | 482.95 | K | N/A | Witschonke, 1954 | Uncertainty assigned by TRC = 0.2 K; TRC |
Enthalpy of fusion
ΔfusH (kJ/mol) | Temperature (K) | Reference | Comment |
---|---|---|---|
38.960 | 483.02 | Sabbah and El Watik, 1992 | DH |
39.0 | 483. | Domalski and Hearing, 1996 | AC |
Mass spectrum (electron ionization)
Go To: Top, Phase change data, UV/Visible spectrum, Gas Chromatography, NIST Subscription Links, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | RADIAN CORP |
NIST MS number | 73018 |
UV/Visible spectrum
Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, NIST Subscription Links, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
View spectrum image in SVG format.
Download spectrum in JCAMP-DX format.
Source | Hartmann and Lorenz, 1952 |
---|---|
Owner | INEP CP RAS, NIST OSRD Collection (C) 2007 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
Origin | INSTITUTE OF ENERGY PROBLEMS OF CHEMICAL PHYSICS, RAS |
Source reference | RAS UV No. 9997 |
Instrument | Beckman spectrophotometer |
Melting point | 211 |
Boiling point | sub |
Gas Chromatography
Go To: Top, Phase change data, Mass spectrum (electron ionization), UV/Visible spectrum, NIST Subscription Links, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Lee's RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5 | 353. | Eckel, 2000 | Program: not specified |
Capillary | DB-5 | 355.88 | Eckel, 2000 | Program: not specified |
Capillary | DB-5 | 356. | Eckel, 2000 | Program: not specified |
Capillary | DB-5 | 356.47 | Eckel, 2000 | Program: not specified |
References
Go To: Top, Phase change data, Mass spectrum (electron ionization), UV/Visible spectrum, Gas Chromatography, NIST Subscription Links, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Anonymous, 1988
Anonymous, X.,
, NBS Spec. Publ. (U. S.) 260, 1988. [all data]
Marsh, 1987
Marsh, K.N.,
Recommended Reference Materials for the Realization of Physicochemical Properties, Blackwell Sci. Pub., Oxford, 1987. [all data]
Witschonke, 1954
Witschonke, C.R.,
Freezing point and purity data for some organic compounds,
Anal. Chem., 1954, 26, 562-4. [all data]
Sabbah and El Watik, 1992
Sabbah, R.; El Watik, L.,
New reference materials for the calibration (temperature and energy) of differential thermal analysers and scanning calorimeters,
J. Therm. Anal., 1992, 38(4), 855-863. [all data]
Domalski and Hearing, 1996
Domalski, Eugene S.; Hearing, Elizabeth D.,
Heat Capacities and Entropies of Organic Compounds in the Condensed Phase. Volume III,
J. Phys. Chem. Ref. Data, 1996, 25, 1, 1, https://doi.org/10.1063/1.555985
. [all data]
Hartmann and Lorenz, 1952
Hartmann, H.; Lorenz, E.,
Z. Naturforsh, 1952, 7a, 360. [all data]
Eckel, 2000
Eckel, W.P.,
Making sense of nontarget compound data from GC-MS library searches,
Am. Lab. Fairfield Conn., 2000, 17-20. [all data]
Notes
Go To: Top, Phase change data, Mass spectrum (electron ionization), UV/Visible spectrum, Gas Chromatography, NIST Subscription Links, References
- Symbols used in this document:
Tfus Fusion (melting) point ΔfusH Enthalpy of fusion - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.