Benzaldehyde, 4-methoxy-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase ZB-WaxDB-FFAPDB-FFAPHP-InnowaxSupelcowax-10
Column length (m) 30.30.15.30.60.
Carrier gas HeHe N2He
Substrate      
Column diameter (mm) 0.250.320.320.250.25
Phase thickness (μm) 0.150.250.250.250.25
Tstart (C) 35.40.30.60.35.
Tend (C) 220.230.225.220.195.
Heat rate (K/min) 5.6.10.5.2.
Initial hold (min) 5.1.2. 5.
Final hold (min) 10. 20. 90.
I 1998.2038.2009.2055.2032.
ReferenceLedauphin, Basset, et al., 2006Zeller and Rychlik, 2006Zhou, Wintersteen, et al., 2002Adamiec, Cejpek, et al., 2001Chung, Yung, et al., 2001
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Supelcowax-10Carbowax 20MDB-WaxDB-WaxDB-Wax
Column length (m) 60.25.60.60.30.
Carrier gas He HeHeHe
Substrate      
Column diameter (mm) 0.250.250.250.250.32
Phase thickness (μm) 0.250.30.250.250.25
Tstart (C) 35.50.50.40.40.
Tend (C) 195.200.230.160.220.
Heat rate (K/min) 2.3.3.2.5.
Initial hold (min)  1. 3.3.
Final hold (min) 90.20. 15. 
I 2035.2023.2016.2027.1980.
ReferenceChung, 2000Bicchi, Fresia, et al., 1997Shimoda, Wu, et al., 1996Stashenko, Martinez, et al., 1995Frohlich and Schreier, 1990
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase DB-WaxDB-Wax
Column length (m) 30.30.
Carrier gas   
Substrate   
Column diameter (mm) 0.250.25
Phase thickness (μm)   
Tstart (C) 50.50.
Tend (C) 240.240.
Heat rate (K/min) 2.2.
Initial hold (min)   
Final hold (min)   
I 2006.82007.3
ReferenceChang, Sheng, et al., 1989Chang, Sheng, et al., 1989
Comment MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Ledauphin, Basset, et al., 2006
Ledauphin, J.; Basset, B.; Cohen, S.; Payot, T.; Barillier, D., Identification of trace volatile compounds in freshly distilled Calvados and Cognac: Carbonyl and sulphur compounds, J. Food Comp. Anal., 2006, 19, 1, 28-40, https://doi.org/10.1016/j.jfca.2005.03.001 . [all data]

Zeller and Rychlik, 2006
Zeller, A.; Rychlik, M., Character impact odorants of fennel fruits and fennel tea, J. Agric. Food Chem., 2006, 54, 10, 3686-3692, https://doi.org/10.1021/jf052944j . [all data]

Zhou, Wintersteen, et al., 2002
Zhou, Q.; Wintersteen, C.L.; Cadwallader, K.R., Identification and quantification of aroma-active components that contribute to the distinct malty flavor of buckwheat honey, J. Agric. Food Chem., 2002, 50, 7, 2016-2021, https://doi.org/10.1021/jf011436g . [all data]

Adamiec, Cejpek, et al., 2001
Adamiec, J.; Cejpek, K.; Rossner, J.; Velisek, J., Novel Strecker degradation products of tyrosine and dihydroxyphenylalanine, Czech. J. Food. Sci., 2001, 19, 1, 13-18. [all data]

Chung, Yung, et al., 2001
Chung, H.Y.; Yung, I.K.S.; Kim, J.-S., Comparison of volatile components in dried scallops (Chlamys farreri and Patinopecten yessoensis) prepared by boiling and steaming methods, J. Agric. Food Chem., 2001, 49, 1, 192-202, https://doi.org/10.1021/jf000692a . [all data]

Chung, 2000
Chung, H.Y., Volatile flavor components in red fermented soybean (Glycine max) curds, J. Agric. Food Chem., 2000, 48, 5, 1803-1809, https://doi.org/10.1021/jf991272s . [all data]

Bicchi, Fresia, et al., 1997
Bicchi, C.; Fresia, M.; Rubiolo, P.; Monti, D.; Franz, C.; Goehler, I., Constituents of Tagetes lucida Cav. ssp. lucida essential oil, Flavour Fragr. J., 1997, 12, 1, 47-52, https://doi.org/10.1002/(SICI)1099-1026(199701)12:1<47::AID-FFJ610>3.0.CO;2-7 . [all data]

Shimoda, Wu, et al., 1996
Shimoda, M.; Wu, Y.; Osajima, Y., Aroma compounds from aqueous solution of Haze (Rhus succedanea) honey determined by adsorptive column chromatography, J. Agric. Food Chem., 1996, 44, 12, 3913-3918, https://doi.org/10.1021/jf9601168 . [all data]

Stashenko, Martinez, et al., 1995
Stashenko, E.E.; Martinez, C.R.; Martinez, J.R.; Shibamoto, T., Catalytic transformation of anise (Pimpinella anisum L.) oil over zeolite Y, J. Hi. Res. Chromatogr., 1995, 18, 8, 501-503, https://doi.org/10.1002/jhrc.1240180810 . [all data]

Frohlich and Schreier, 1990
Frohlich, O.; Schreier, P., Volatile Constituents of Loquat (Eriobotrya japonica Lindl.) Fruit, J. Food Sci., 1990, 55, 1, 176-180, https://doi.org/10.1111/j.1365-2621.1990.tb06046.x . [all data]

Chang, Sheng, et al., 1989
Chang, L.P.; Sheng, L.S.; Yang, M.Z.; An, D.K., Retention index of essential oil in temperature-programmed capillary column gas chromatography, Acta Pharm. Sin., 1989, 24, 11, 847-852. [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, polar column, temperature ramp, References