Omethoate


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryUltra-2200.1640.Li, Guan, et al., 1995Column length: 50. m; Column diameter: 0.32 mm
CapillaryUltra-2220.1640.Li, Guan, et al., 1995Column length: 50. m; Column diameter: 0.32 mm
CapillaryOV-1160.1588.Erdmann, Rochholz, et al., 1992 
CapillaryOV-1190.1603.Erdmann, Rochholz, et al., 1992 
CapillaryOV-1220.1628.Erdmann, Rochholz, et al., 1992 

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-11630.Guan, Li, et al., 199550. m/0.20 mm/0.6 μm, H2, 2. K/min; Tstart: 180. C; Tend: 240. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
Capillary5 % Phenyl methyl siloxane1596.Department of Food Safety and Welfare, 200630. m/0.25 mm/0.25 μm, Helium; Program: 50 0C(1 min) 25 0C/min -> 125 0C 10 0C/min -> 300 0C (10 min)
Capillary5 % Phenyl methyl siloxane1596.Department of Food Safety and Welfare, 200630. m/0.25 mm/0.25 μm, Helium; Program: 50 0C(1 min) 25 0C/min -> 125 0C 10 0C/min -> 300 0C (10 min)

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Li, Guan, et al., 1995
Li, L.; Guan, Y.; Zhou, L., Standard Kovats indexes of 20 pesticides and their identification in temperature-programmed capillary gas chromatography., Fenxi Huaxue, 1995, 23, 1, 14-19. [all data]

Erdmann, Rochholz, et al., 1992
Erdmann, F.; Rochholz, G.; Schütz, H., Retention-indices on OV-1 of approximately 170 commonly used pesticides, Mikrochim. Acta, 1992, 106, 3-6, 219-226, https://doi.org/10.1007/BF01242093 . [all data]

Guan, Li, et al., 1995
Guan, Y.; Li, L.; Zhou, L., Factors affecting the reproducibility and reliability of retention simulation in any form of temperature programmed capillary GC, J. Hi. Res. Chromatogr., 1995, 18, 9, 593-596, https://doi.org/10.1002/jhrc.1240180916 . [all data]

Department of Food Safety and Welfare, 2006
Department of Food Safety, Ministry of Health; Welfare, Analytical methods for residual compositional substances of agricultural chemicals, feed aadditives, and veterinary drugs in foods, 2006, retrieved from http://www.mhlw.go.jp/english/topics/foodsafety/positivelist060228/de/060526-1a.pdf. [all data]


Notes

Go To: Top, Gas Chromatography, References