1-Hexanol
- Formula: C6H14O
- Molecular weight: 102.1748
- IUPAC Standard InChIKey: ZSIAUFGUXNUGDI-UHFFFAOYSA-N
- CAS Registry Number: 111-27-3
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Isotopologues:
- Other names: Hexyl alcohol; n-Hexan-1-ol; n-Hexanol; n-Hexyl alcohol; Amylcarbinol; Caproyl alcohol; Hexanol; Pentylcarbinol; 1-Hexyl alcohol; 1-Hydroxyhexane; n-C6H13OH; Hexan-1-ol; Hexanol-(1); Epal 6; NSC 9254
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
- NIST / TRC Web Thermo Tables, "lite" edition (thermophysical and thermochemical data)
- NIST / TRC Web Thermo Tables, professional edition (thermophysical and thermochemical data)
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Kovats' RI, non-polar column, isothermal
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | HP-1 | HP-1 | HP-1 | HP-1 | HP-1 |
Column length (m) | 30. | 30. | 30. | 30. | 30. |
Carrier gas | |||||
Substrate | |||||
Column diameter (mm) | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 |
Phase thickness (μm) | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 |
Temperature (C) | 0. | 10. | 20. | 30. | 40. |
I | 889.4 | 896.8 | 870.1 | 866.3 | 862.3 |
Reference | Wang, Liu, et al., 2005 | Wang, Liu, et al., 2005 | Wang, Liu, et al., 2005 | Wang, Liu, et al., 2005 | Wang, Liu, et al., 2005 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | HP-1 | HP-1 | HP-101 | SE-30 | SE-30 |
Column length (m) | 30. | 30. | 50. | 40. | |
Carrier gas | H2 | ||||
Substrate | |||||
Column diameter (mm) | 0.25 | 0.25 | 0.2 | 0.35 | |
Phase thickness (μm) | 0.25 | 0.25 | 0.2 | 0.35 | |
Temperature (C) | 50. | 60. | 60. | 100. | 100. |
I | 861.1 | 859.9 | 859.54 | 848. | 848.2 |
Reference | Wang, Liu, et al., 2005 | Wang, Liu, et al., 2005 | Garay, 2000 | Tudor and Moldovan, 1999 | Tudor, 1997 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary | Capillary | Packed |
---|---|---|---|---|---|
Active phase | OV-101 | OV-101 | OV-101 | OV-101 | SE-30 |
Column length (m) | 20. | 20. | 100. | 100. | 1. |
Carrier gas | N2 | N2 | He | ||
Substrate | Chromaton N Super (75-100 mesh) | ||||
Column diameter (mm) | 0.5 | 0.5 | 0.27 | 0.27 | |
Phase thickness (μm) | |||||
Temperature (C) | 150. | 180. | 80. | 90. | 170. |
I | 831.9 | 836.6 | 878. | 879.5 | 822. |
Reference | Cha and Lee, 1994 | Cha and Lee, 1994 | Boneva, 1987 | Boneva, 1987 | Voelkel, 1987 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary | Capillary | Packed |
---|---|---|---|---|---|
Active phase | SE-30 | SE-30 | SE-30 | SE-30 | SE-30 |
Column length (m) | 25. | 25. | 25. | 25. | 3. |
Carrier gas | Ar | ||||
Substrate | Gas Chrom Q (80-100 mesh) | ||||
Column diameter (mm) | 0.33 | 0.33 | 0.33 | 0.33 | |
Phase thickness (μm) | |||||
Temperature (C) | 100. | 120. | 160. | 80. | 150. |
I | 851. | 845. | 823. | 863. | 860. |
Reference | Haken and Korhonen, 1985 | Haken and Korhonen, 1985 | Haken and Korhonen, 1985 | Haken and Korhonen, 1985 | Tiess, 1984 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Packed | Packed | Packed | Packed | Packed |
---|---|---|---|---|---|
Active phase | SE-30 | SE-30 | Apiezon L | Apiezon L | SE-30 |
Column length (m) | 2. | 3.7 | 1. | ||
Carrier gas | Ar | ||||
Substrate | Gaschrom Q | Celatom AW silanized | Celite 545 | Celite 545 | Chromosorb W AW DMCS HP (80-100 mesh) |
Column diameter (mm) | |||||
Phase thickness (μm) | |||||
Temperature (C) | 100. | 150. | 120. | 160. | 100. |
I | 854. | 852. | 831. | 838. | 856. |
Reference | Winskowski, 1983 | Haken, Nguyen, et al., 1979 | Bogoslovsky, Anvaer, et al., 1978 | Bogoslovsky, Anvaer, et al., 1978 | Pías and Gascó, 1975 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Packed | Packed | Capillary | Packed | Packed |
---|---|---|---|---|---|
Active phase | SE-30 | SE-30 | Squalane | Squalane | SE-30 |
Column length (m) | 1. | 1. | 100. | 2. | |
Carrier gas | Ar | Ar | |||
Substrate | Chromosorb W AW DMCS HP (80-100 mesh) | Chromosorb W AW DMCS HP (80-100 mesh) | Chromosorb G | Chromosorb W | |
Column diameter (mm) | 0.25 | ||||
Phase thickness (μm) | |||||
Temperature (C) | 120. | 140. | 100. | 50. | 100. |
I | 853. | 850. | 831.2 | 831. | 855. |
Reference | Pías and Gascó, 1975 | Pías and Gascó, 1975 | Schomburg and Dielmann, 1973 | Mira and Sanchez, 1970 | Zarazir, Chovin, et al., 1970 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Packed |
---|---|
Active phase | SE-30 |
Column length (m) | 2. |
Carrier gas | |
Substrate | Chromosorb W |
Column diameter (mm) | |
Phase thickness (μm) | |
Temperature (C) | 140. |
I | 856. |
Reference | Zarazir, Chovin, et al., 1970 |
Comment | MSDC-RI |
References
Go To: Top, Kovats' RI, non-polar column, isothermal, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Wang, Liu, et al., 2005
Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W.,
Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures,
Microchem. J., 2005, 81, 2, 184-190, https://doi.org/10.1016/j.microc.2005.02.003
. [all data]
Garay, 2000
Garay, F.,
Application of a flow-tunable, serially coupled gas chromatographic capillary column system for the analysis of complex mixtures,
Chromatographia Sup., 2000, 51, 1, s108-s120, https://doi.org/10.1007/BF02492792
. [all data]
Tudor and Moldovan, 1999
Tudor, E.; Moldovan, D.,
Temperature Dependence of the Retention Index for Perfumery Compounds on a Se-30 Glass Capillary Column. II. The Hyperbolic Equation,
J. Chromatogr., 1999, 848, 1-2, 215-227, https://doi.org/10.1016/S0021-9673(99)00412-4
. [all data]
Tudor, 1997
Tudor, E.,
Temperature dependence of the retention index for perfumery compounds on a SE-30 glass capillary column. I. Linear equations,
J. Chromatogr. A, 1997, 779, 1-2, 287-297, https://doi.org/10.1016/S0021-9673(97)00453-6
. [all data]
Cha and Lee, 1994
Cha, K.-W.; Lee, D.-J.,
Prediction of retention indices of various compounds in gas-liquid chromatography,
J. Korean Chem. Soc., 1994, 38, 2, 108-120, retrieved from http://journal.kcsnet.or.kr/publi/dh/dh94n2/108.pdf. [all data]
Boneva, 1987
Boneva, S.,
Gas Chromatographic Retention Indices for C6 Alkanols on OV-101 and Carbowax 20M Capillary Columns,
Chromatographia, 1987, 23, 1, 50-52, https://doi.org/10.1007/BF02310419
. [all data]
Voelkel, 1987
Voelkel, A.,
Retention Indices and Thermodynamic Functions of Solution for Model Non-Ionic Surfactants in Standard Stationary Phases Determined by Gas Chromatography,
J. Chromatogr., 1987, 387, 95-104, https://doi.org/10.1016/S0021-9673(01)94516-9
. [all data]
Haken and Korhonen, 1985
Haken, J.K.; Korhonen, I.O.O.,
Gas chromatography of homologous esters. XXVII. Retention increments of C1-C18 primary alkanols and their 2-chloropropanoyl and 3-chloropropanoyl derivatives on SE-30 and OV-351 capillary columns,
J. Chromatogr., 1985, 319, 131-142, https://doi.org/10.1016/S0021-9673(01)90548-5
. [all data]
Tiess, 1984
Tiess, D.,
Gaschromatographische Retentionsindices von 125 leicht- bis mittelflüchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30,
Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 1984, 33, 6-9. [all data]
Winskowski, 1983
Winskowski, J.,
Gaschromatographische Identifizierung von Stoffen anhand von Indexziffem und unterschiedlichen Detektoren,
Chromatographia, 1983, 17, 3, 160-165, https://doi.org/10.1007/BF02271041
. [all data]
Haken, Nguyen, et al., 1979
Haken, J.K.; Nguyen, A.; Wainwright, M.S.,
Application of linear extrathermodynamic relationships to alcohols, aldehydes, ketones, amd ethoxy alcohols,
J. Chromatogr., 1979, 179, 1, 75-85, https://doi.org/10.1016/S0021-9673(00)80658-5
. [all data]
Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S.,
Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]
Pías and Gascó, 1975
Pías, J.B.; Gascó, L.,
GC Retention Data of Alcohols and Benzoyl Derivatives of Alcohols,
J. Chromatogr. - Chrom. Data, 1975, d14-d16. [all data]
Schomburg and Dielmann, 1973
Schomburg, G.; Dielmann, G.,
Identification by means of retention parameters,
J. Chromatogr. Sci., 1973, 11, 3, 151-159, https://doi.org/10.1093/chromsci/11.3.151
. [all data]
Mira and Sanchez, 1970
Mira, J.M.; Sanchez, L.G.,
Polarity of the Gas Chromatographic Stationary Phases and Retention Indices of Aliphatic Esters, Ketones and Alcohols,
Anal. Chim. Acta., 1970, 50, 2, 315-321, https://doi.org/10.1016/0003-2670(70)80071-X
. [all data]
Zarazir, Chovin, et al., 1970
Zarazir, D.; Chovin, P.; Guiochon, G.,
Identification of hydroxylic compounds and their derivatives by gas chromatography,
Chromatographia, 1970, 3, 4, 180-195, https://doi.org/10.1007/BF02269018
. [all data]
Notes
Go To: Top, Kovats' RI, non-polar column, isothermal, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.