Squalane

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillarySE-30240.2665.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-30240.2666.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-30240.2666.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-30240.2667.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-30260.2665.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-30260.2666.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-30260.2666.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-30260.2666.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-52240.2657.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-52240.2657.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-52260.2658.1Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm
CapillarySE-52260.2658.5Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP-52660.Zhao, Wang X.Y., et al., 200630. m/0.25 mm/0.25 μm, He, 50. C @ 3. min, 10. K/min; Tend: 260. C
CapillarySE-302664.4Pozhidaev, Berezkin, et al., 1988He, 2. K/min; Column length: 17.5 m; Column diameter: 0.21 mm; Tstart: 100. C; Tend: 280. C
CapillarySE-522656.1Pozhidaev, Berezkin, et al., 1988He, 2. K/min; Column length: 17.5 m; Column diameter: 0.21 mm; Tstart: 100. C; Tend: 280. C
CapillaryUltra-12663.Tokuda, Saitoh, et al., 198812.5 m/0.20 mm/0.11 μm, He, 5. K/min, 325. C @ 5. min; Tstart: 120. C

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillarySE-52240.2657.Pozhidaev, Berezkin, et al., 1988He; Column length: 17.5 m; Column diameter: 0.21 mm

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillarySE-302668.Pozhidaev, Berezkin, et al., 1987He, 6. K/min; Column length: 25. m; Column diameter: 0.21 mm; Tstart: 40. C; Tend: 280. C
CapillaryApiezon L2630.Shlyakhov, 19842. K/min; Tstart: 130. C; Tend: 300. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryCP Sil 5 CB2663.Kenig, Sinninghe Damsté, et al., 199525. m/0.32 mm/0.2 μm, He; Program: 50C => 20C/min => 130C => 4C/min => 300C (20min)
CapillaryApiezon2630.Petrov, 1984Program: not specified
CapillaryApiezon2632.Petrov, 1984Program: not specified

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Pozhidaev, Berezkin, et al., 1988
Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 1988, 43, 1082-1088. [all data]

Zhao, Wang X.Y., et al., 2006
Zhao, Y.P.; Wang X.Y.; Wang, Z.C.; Lu Y.; Fu, C.X.; Chen, S.Y., Essential oil of Actinidia macrosperma, a catnip response kiwi endemic to China, Journal of Zhejiang University SCIENCE B, 2006, 7, 9, 708-712, https://doi.org/10.1631/jzus.2006.B0708 . [all data]

Tokuda, Saitoh, et al., 1988
Tokuda, H.; Saitoh, E.; Kimura, Y.; Takano, S., Automated analysis of various compounds with a wide range of boiling points by capillary gas chromatgraphy based on retention indices, J. Chromatogr., 1988, 454, 109-120, https://doi.org/10.1016/S0021-9673(00)88606-9 . [all data]

Pozhidaev, Berezkin, et al., 1987
Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhideava, Capillary chromatography of polycyclic aromatic hydrocarbons on a home-produced capillary column with immobilized stationary liquid phase SE-30, Zh. Anal. Khim., 1987, 62, 12, 2222-2226. [all data]

Shlyakhov, 1984
Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221. [all data]

Kenig, Sinninghe Damsté, et al., 1995
Kenig, F.; Sinninghe Damsté, J.S.; Kock-van Dalen, A.C.; Rijpstra, W.I.C.; Huc, A.Y.; de Leeuw, J.W., Occurrence and origin of mono-, di-, and trimethylalkanes in modern and holocene cyanobacterial mats from Abu Dhabi, United Arab Emirates, Geochim. Cosmochim. Acta, 1995, 59, 14, 2999-3015, https://doi.org/10.1016/0016-7037(95)00190-5 . [all data]

Petrov, 1984
Petrov, A.A., Hydrocarbons of petroleum, Nauka (publishing house), Moscow, 1984, 263. [all data]


Notes

Go To: Top, Gas Chromatography, References