Pentanal
- Formula: C5H10O
- Molecular weight: 86.1323
- IUPAC Standard InChIKey: HGBOYTHUEUWSSQ-UHFFFAOYSA-N
- CAS Registry Number: 110-62-3
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
View 3d structure (requires JavaScript / HTML 5) - Other names: Valeraldehyde; n-Pentanal; n-Valeraldehyde; Valeral; Valerianic aldehyde; Valeric acid aldehyde; Valeric aldehyde; Valeryl aldehyde; n-C4H9CHO; Amyl aldehyde; Butyl formal; UN 2058; n-Valeric aldehyde; 1-Pentanal; Pentan-1-al; NSC 35404; Pentylaldehyde; pentanal (valeraldehyde); valderaldehyde
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
- NIST / TRC Web Thermo Tables, "lite" edition (thermophysical and thermochemical data)
- NIST / TRC Web Thermo Tables, professional edition (thermophysical and thermochemical data)
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal boiling point
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
Tboil (K) | Reference | Comment |
---|---|---|
376.2 | Weast and Grasselli, 1989 | BS |
375.83 | Markovnik, Sachek, et al., 1979 | Uncertainty assigned by TRC = 0.02 K; TRC |
376.15 | Gaiffe and Palland, 1962 | Uncertainty assigned by TRC = 2. K; TRC |
375.65 | Sisti, Burgmaster, et al., 1962 | Uncertainty assigned by TRC = 2. K; TRC |
375.15 | Hickey, 1948 | Uncertainty assigned by TRC = 2. K; TRC |
376. | Schniepp and Geller, 1945 | Uncertainty assigned by TRC = 4. K; TRC |
376.65 | Prevost, 1944 | Uncertainty assigned by TRC = 1.5 K; TRC |
375.65 | Komarewsky and Kritchevsky, 1943 | Uncertainty assigned by TRC = 2. K; TRC |
375.35 | Coomber and Partington, 1938 | Uncertainty assigned by TRC = 1.5 K; TRC |
374.15 | Kuhn and Grundmann, 1937 | Uncertainty assigned by TRC = 3. K; TRC |
375.65 | Swan and Field, 1937 | Uncertainty assigned by TRC = 3. K; TRC |
375.25 | Kohlraush and Koppl, 1934 | Uncertainty assigned by TRC = 2. K; TRC |
373.65 | Whitmore and Church, 1933 | Uncertainty assigned by TRC = 3. K; TRC |
375.9 | Bruylants, 1931 | Uncertainty assigned by TRC = 2. K; TRC |
376.9 | Simon, 1929 | Uncertainty assigned by TRC = 1. K; TRC |
376.15 | Parnas, 1910 | Uncertainty assigned by TRC = 2. K; TRC |
374.65 | Blaise, 1904 | Uncertainty assigned by TRC = 3. K; TRC |
376.55 | Zander, 1884 | Uncertainty assigned by TRC = 3. K; TRC |
375.15 | Lieben and Rossi, 1871 | Uncertainty assigned by TRC = 3. K; TRC |
References
Go To: Top, Normal boiling point, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]
Markovnik, Sachek, et al., 1979
Markovnik, V.S.; Sachek, A.I.; Peshchenko, A.D.; Shvaro, O.V.; Andreevskii, D.N.; Olizarevich, N.M.,
Termodin. Org. Soedin., 1979, 107. [all data]
Gaiffe and Palland, 1962
Gaiffe, A.; Palland, R.,
C. R. Hebd. Seances Acad. Sci., 1962, 254, 496. [all data]
Sisti, Burgmaster, et al., 1962
Sisti, A.J.; Burgmaster, J.; Fudim, M.,
J. Org. Chem., 1962, 27, 279. [all data]
Hickey, 1948
Hickey, M.J.,
J. Org. Chem., 1948, 13, 443. [all data]
Schniepp and Geller, 1945
Schniepp, L.E.; Geller, H.H.,
J. Am. Chem. Soc., 1945, 67, 54. [all data]
Prevost, 1944
Prevost, C.,
Bull. Soc. Chim. Fr., 1944, 11, 218. [all data]
Komarewsky and Kritchevsky, 1943
Komarewsky, V.I.; Kritchevsky, T.H.,
Synthesis of Olefin Hydrocarbons by Catalytic Condensation and Dehydration of Aliphatic Aldehydes,
J. Am. Chem. Soc., 1943, 65, 547-8. [all data]
Coomber and Partington, 1938
Coomber, D.I.; Partington, J.R.,
Studies in dielectric polarisation part xxiii the dipole moments of some aliphatic and aromatic aldehydes and of anthrone,
J. Chem. Soc., 1938, 1938, 1444. [all data]
Kuhn and Grundmann, 1937
Kuhn, R.; Grundmann, C.,
Chem. Ber., 1937, 70, 1894. [all data]
Swan and Field, 1937
Swan, S.; Field, E.W.,
Trans. Electrochem. Soc., 1937, 72, 327. [all data]
Kohlraush and Koppl, 1934
Kohlraush, K.W.F.; Koppl, F.,
Z. Phys. Chem., Abt. B, 1934, 24, 370. [all data]
Whitmore and Church, 1933
Whitmore, F.C.; Church, J.M.,
J. Am. Chem. Soc., 1933, 55, 1119. [all data]
Bruylants, 1931
Bruylants, P.,
Contribution to the study of ethylene nitriles beta-ethyl-crotonic nitrile,
Bull. Cl. Sci., Acad. R. Belg., 1931, 17, 1008. [all data]
Simon, 1929
Simon, I.,
Freezing Temperature of Organic Compounds. XI. Compounds in C5 and C6.,
Bull. Soc. Chim. Belg., 1929, 38, 47-70. [all data]
Parnas, 1910
Parnas, J.,
Biochem. Z., 1910, 28, 274. [all data]
Blaise, 1904
Blaise, E.E.,
Bull. Soc. Chim. Fr., 1904, 31, 483. [all data]
Zander, 1884
Zander, A.,
The specific volumes of liquid compounds: IV normal fatty acids and normal fatty alcohols,
Justus Liebigs Ann. Chem., 1884, 224, 56-95. [all data]
Lieben and Rossi, 1871
Lieben, A.; Rossi, A.,
Justus Liebigs Ann. Chem., 1871, 159, 58. [all data]
Notes
Go To: Top, Normal boiling point, References
- Symbols used in this document:
Tboil Boiling point - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.