Phenol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5MSVF-5MSVF-5MSVF-5MSDB-5MS
Column length (m) 30.50.50.50.30.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.320.250.250.250.32
Phase thickness (μm) 0.50.250.250.250.5
Program 70C => 5C/min => 85C(1min) => 3C/min => 165C => 10C/min => 280C(3min)60C(2min) => 30C/min => 100C => 1C/min => 60C(2min) => 30C/min => 100C => 2C/min => 60C(2min) => 30C/min => 100C => 4C/min => 70C(1min) => 3C/min => 80C(1min) => 5C/min => 150C => 10C/min => 280C (4min)
I 992.1004.1995.5986.8992.
ReferenceVarlet, Serot, et al., 2007Mjøs, Meier, et al., 2006Mjøs, Meier, et al., 2006Mjøs, Meier, et al., 2006Varlet V., Knockaert C., et al., 2006
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5MSDB-1DB-15 % Phenyl methyl siloxaneMethyl Silicone
Column length (m) 30.60.3.25. 
Carrier gas HeHeHeHe 
Substrate      
Column diameter (mm) 0.320.320.320.31 
Phase thickness (μm) 0.51.0.30.52 
Program 70C(1min) => 3C/min => 80C(1min) => 5C/min => 150C => 10C/min => 280C (4min)35C(5min) => 10C/min => 45C (5min) => 5C/min => 250C (10min)-20C(6min) => 8C/min =60C => 6C/min => 220C(5min)50C(2min) => (20C/min) => 120C => (7C/min) => 310C(10min)not specified
I 992.955.953.980.962.
ReferenceVarlet V., Knockaert C., et al., 2006Place, Imhof, et al., 2003Whetstine, Parker, et al., 2003Yasuhara, Shiraishi, et al., 1997Peng, Yang, et al., 1991
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Varlet, Serot, et al., 2007
Varlet, V.; Serot, T.; Cardinal, M.; Knockaert, C.; Prost, C., Olfactometric Determination of the Most Potent Odor-Active Compounds in Salmon Muscle (Salmo salar) Smoked by Using Four Smoke Generation Techniques, J. Agric. Food Chem., 2007, 55, 11, 4518-4525, https://doi.org/10.1021/jf063468f . [all data]

Mjøs, Meier, et al., 2006
Mjøs, S.A.; Meier, S.; Boitsov, S., Alkylphenol retention indices, J. Chromatogr. A, 2006, 1123, 1, 98-105, https://doi.org/10.1016/j.chroma.2006.05.002 . [all data]

Varlet V., Knockaert C., et al., 2006
Varlet V.; Knockaert C.; Prost C.; Serot T., Comparison of odor-active volatile compounds of fresh and smoked salmon, J. Agric. Food Chem., 2006, 54, 9, 3391-3401, https://doi.org/10.1021/jf053001p . [all data]

Place, Imhof, et al., 2003
Place, R.B.; Imhof, M.; Teuber, M.; Olivier Bosset, J., Distribution of the volatile (flavour) compounds in Raclette cheese produced with different staphylococci in the smear, Mitt. Lebensmittelunters. Hyg., 2003, 94, 192-211. [all data]

Whetstine, Parker, et al., 2003
Whetstine, M.E.C.; Parker, J.D.; Drake, M.A.; Larick, D.K., Determining flavor and flavor variability in commercially produced liquid cheddar whey, J. Dairy Sci., 2003, 86, 2, 439-448, https://doi.org/10.3168/jds.S0022-0302(03)73622-4 . [all data]

Yasuhara, Shiraishi, et al., 1997
Yasuhara, A.; Shiraishi, H.; Nishikawa, M.; Yamamoto, T.; Uehiro, T.; Nakasugi, O.; Okumura, T.; Kenmotsu, K.; Fukui, H.; Nagase, M.; Ono, Y.; Kawagoshi, Y.; Baba, K.; Noma, Y., Determination of organic components in leachates from hazardous waste disposal sites in Japan by gas chromatography-mass spectrometry, J. Chromatogr. A, 1997, 774, 1-2, 321-332, https://doi.org/10.1016/S0021-9673(97)00078-2 . [all data]

Peng, Yang, et al., 1991
Peng, C.T.; Yang, Z.C.; Maltby, D., Prediction of retention indexes. III. Silylated derivatives of polar compounds, J. Chromatogr., 1991, 586, 1, 113-129, https://doi.org/10.1016/0021-9673(91)80029-G . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, custom temperature program, References