2,6-Lutidine

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedCapillaryCapillary
Active phase C78, Branched paraffinC78, Branched paraffinApolaneSE-30SE-30
Column length (m) 3.33.33.725.25.
Carrier gas He  HeHe
Substrate  Chromosorb G HP   
Column diameter (mm)    0.320.32
Phase thickness (μm)    1.1.
Temperature (C) 130.130.130.110.80.
I 872.0870.1874.869.866.
ReferenceDallos, Sisak, et al., 2000Reddy, Dutoit, et al., 1992Dutoit, 1991Samusenko and Golovnya, 1988Samusenko and Golovnya, 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101OV-101OV-101OV-101
Column length (m) 20.25.35.35.35.
Carrier gas N2HeHeHeHe
Substrate      
Column diameter (mm) 0.230.250.250.250.25
Phase thickness (μm)  0.1560.1250.1250.125
Temperature (C) 150.80.80.80.80.
I 876.866.866.866.866.
ReferenceMorishita, Morimoto, et al., 1986Samusenko, Svetlova, et al., 1986Samusenko, Svetlova, et al., 1986Samusenko, Svetlova, et al., 1986Samusenko, Svetlova, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPackedPackedPackedPacked
Active phase OV-101Apiezon LApolaneApiezon LPMS-100
Column length (m) 50.2.42.42.73.
Carrier gas HeHeHeN2 or HeHe
Substrate  Chromosorb W AW-DMCSChromosorbChromosorb G, AWCelite 545 (44-60 mesh)
Column diameter (mm) 0.25    
Phase thickness (μm) 0.125    
Temperature (C) 80.130.70.100.130.
I 868.903.863.8880.868.
ReferenceSamusenko, Svetlova, et al., 1986Shatts, Avots, et al., 1977Riedo, Fritz, et al., 1976Zhuravleva, Kapustin, et al., 1976Anderson, Jurel, et al., 1973
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase PMS-100PMS-100
Column length (m) 3.3.
Carrier gas HeHe
Substrate Celite 545 (44-60 mesh)Celite 545 (44-60 mesh)
Column diameter (mm)   
Phase thickness (μm)   
Temperature (C) 150.180.
I 852.850.
ReferenceAnderson, Jurel, et al., 1973Anderson, Jurel, et al., 1973
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Dallos, Sisak, et al., 2000
Dallos, A.; Sisak, A.; Kulcsár, Z.; Kováts, E., Pair-wise interactions by gas chromatography VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A, 2000, 904, 2, 211-242, https://doi.org/10.1016/S0021-9673(00)00908-0 . [all data]

Reddy, Dutoit, et al., 1992
Reddy, K.S.; Dutoit, J.-Cl.; Kovats, E. sz., Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr., 1992, 609, 1-2, 229-259, https://doi.org/10.1016/0021-9673(92)80167-S . [all data]

Dutoit, 1991
Dutoit, J., Gas chromatographic retention behaviour of some solutes on structurally similar polar and non-polar stationary phases, J. Chromatogr., 1991, 555, 1-2, 191-204, https://doi.org/10.1016/S0021-9673(01)87179-X . [all data]

Samusenko and Golovnya, 1988
Samusenko, A.L.; Golovnya, R.V., Prediction of the retention indices of methyl pyridines and pyrazines in capillary gas chromatography based on the non-linear additivity of the sorption energy, Chromatographia, 1988, 25, 6, 531-535, https://doi.org/10.1007/BF02324828 . [all data]

Morishita, Morimoto, et al., 1986
Morishita, F.; Morimoto, S.; Kojima, T., Prediction of molecular structures of aza-arenes by retention indices and fluorescence spectra, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 11, 688-692, https://doi.org/10.1002/jhrc.1240091120 . [all data]

Samusenko, Svetlova, et al., 1986
Samusenko, A.L.; Svetlova, N.I.; Golovnya, R.V., Reproducible and durable glass capillary columns with hydrogenated apiezon-l and OV-101 for the analysis of polar substances, Zh. Anal. Khim., 1986, 61, 1, 127-133. [all data]

Shatts, Avots, et al., 1977
Shatts, V.D.; Avots, A.A.; Belikov, V.A., Retention indices of alkylpyridines, Zh. Anal. Khim., 1977, 32, 4, 631-638. [all data]

Riedo, Fritz, et al., 1976
Riedo, F.; Fritz, D.; Tarján, G.; Kováts, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 1976, 126, 63-83, https://doi.org/10.1016/S0021-9673(01)84063-2 . [all data]

Zhuravleva, Kapustin, et al., 1976
Zhuravleva, I.L.; Kapustin, Yu.P.; Golovnya, P.B., Retention indices of some isoaliphatic and heterocyclic nitrogenous bases, Zh. Anal. Khim., 1976, 31, 1378-1380. [all data]

Anderson, Jurel, et al., 1973
Anderson, A.; Jurel, S.; Shymanska, M.; Golender, L., Gas-liquid chromatography of some aliphatic and heterocyclic mono- and pollyfunctional amines. VII. Retention indices of amines in some polar and unpolar stationary phases, Latv. PSR Zinat. Akad. Vestis Kim. Ser., 1973, 1, 51-63. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References