Phenol, 3-methyl-
- Formula: C7H8O
- Molecular weight: 108.1378
- IUPAC Standard InChIKey: RLSSMJSEOOYNOY-UHFFFAOYSA-N
- CAS Registry Number: 108-39-4
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
View 3d structure (requires JavaScript / HTML 5) - Other names: m-Cresol; m-Cresole; m-Cresylic acid; m-Hydroxytoluene; m-Kresol; m-Methylphenol; m-Oxytoluene; m-Toluol; 1-Hydroxy-3-methylbenzene; 3-Cresol; 3-Hydroxytoluene; 3-Methylphenol; meta-Cresol; Cresol, meta; Rcra waste number U052; Cresol,m-; NSC 8768
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
- NIST / TRC Web Thermo Tables, "lite" edition (thermophysical and thermochemical data)
- NIST / TRC Web Thermo Tables, professional edition (thermophysical and thermochemical data)
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal boiling point
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
BS - Robert L. Brown and Stephen E. Stein
Tboil (K) | Reference | Comment |
---|---|---|
475.5 | Cepeda, Gonzalez, et al., 1989 | Uncertainty assigned by TRC = 0.5 K; TRC |
475.5 | Cepeda, Gonzalez, et al., 1989, 2 | Uncertainty assigned by TRC = 0.3 K; TRC |
475.4 | Weast and Grasselli, 1989 | BS |
475.25 | von Terres, Gebert, et al., 1955 | Uncertainty assigned by TRC = 1. K; TRC |
474.95 | Tschamler and Krischai, 1951 | Uncertainty assigned by TRC = 1. K; TRC |
475.35 | Lecat, 1949 | Uncertainty assigned by TRC = 1. K; TRC |
475.35 | Pardee and Weinrich, 1944 | Uncertainty assigned by TRC = 1. K; TRC |
475.35 | Lecat, 1943 | Uncertainty assigned by TRC = 0.4 K; TRC |
475.85 | Timmermans and Hennaut-Roland, 1937 | Uncertainty assigned by TRC = 0.3 K; TRC |
474.65 | Piatti, 1931 | Uncertainty assigned by TRC = 1. K; TRC |
475.15 | Bhatnagar, Mathur, et al., 1930 | Uncertainty assigned by TRC = 2. K; TRC |
474.15 | Schoorl, 1929 | Uncertainty assigned by TRC = 2. K; TRC |
475.28 | Kendall and Beaver, 1921 | Uncertainty assigned by TRC = 0.5 K; TRC |
475.25 | Dawson and Mountford, 1918 | Uncertainty assigned by TRC = 1. K; TRC |
474.95 | Masse and Leroux, 1916 | Uncertainty assigned by TRC = 1. K; TRC |
474.2 | Richards and Mathews, 1908 | Uncertainty assigned by TRC = 1. K; TRC |
475.15 | Perkin, 1896 | Uncertainty assigned by TRC = 1. K; TRC |
475.95 | Pinette, 1888 | Uncertainty assigned by TRC = 2. K; TRC |
References
Go To: Top, Normal boiling point, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Cepeda, Gonzalez, et al., 1989
Cepeda, E.; Gonzalez, C.; Resa, J.M.,
Isobaric vapor-Liquid Equilibrium for the Cumene-Phenol System,
J. Chem. Eng. Data, 1989, 34, 270. [all data]
Cepeda, Gonzalez, et al., 1989, 2
Cepeda, E.; Gonzalez, C.; Resa, J.M.; Ortiz de Salido, C.,
Isobaric Vapor-Liquid Equilibrium for the Cumene-m-Cresol and Phenol- m-Cresol Systems at 13.33 kPa,
J. Chem. Eng. Data, 1989, 34, 429. [all data]
Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]
von Terres, Gebert, et al., 1955
von Terres, E.; Gebert, F.; Hulsemann, H.; Petereit, H.; Toepsch, H.; Ruppert, W.,
Brennst.-Chem., 1955, 36, 272. [all data]
Tschamler and Krischai, 1951
Tschamler, H.; Krischai, H.,
Binary liquid mixtures: XV. Quinoline + m-cresol, a strongly neg. system,
Monatsh. Chem., 1951, 82, 259. [all data]
Lecat, 1949
Lecat, M.,
Tables Azeotropiques, Vol. 1, 10th ed., Brussels, Belgium, 1949. [all data]
Pardee and Weinrich, 1944
Pardee, W.A.; Weinrich, W.,
Physical properties of alkylated phenols,
Ind. Eng. Chem., 1944, 36, 595. [all data]
Lecat, 1943
Lecat, M.,
Azeotropes of Ethyl Urethane and other Azeotropes,
C. R. Hebd. Seances Acad. Sci., 1943, 217, 273. [all data]
Timmermans and Hennaut-Roland, 1937
Timmermans, J.; Hennaut-Roland, M.,
Works from International Bureau at Physical-Chemical Standards. VIII. Physical constants of 20 organic compounds,
J. Chim. Phys. Phys.-Chim. Biol., 1937, 34, 693. [all data]
Piatti, 1931
Piatti, L.,
Z. Phys. Chem., Abt. A, 1931, 152, 36. [all data]
Bhatnagar, Mathur, et al., 1930
Bhatnagar, S.S.; Mathur, R.N.; Mal, R.S.,
Philos. Mag., 1930, 10, 101. [all data]
Schoorl, 1929
Schoorl, N.,
The influence of position isomerism on some specific constants.,
Recl. Trav. Chim. Pays-Bas, 1929, 48, 935. [all data]
Kendall and Beaver, 1921
Kendall, J.; Beaver, J.J.,
Compound Formation in Phenol-cresol Mixtures,
J. Am. Chem. Soc., 1921, 43, 1853. [all data]
Dawson and Mountford, 1918
Dawson, H.M.; Mountford, C.A.,
J. Chem. Soc., Trans., 1918, 113, 937. [all data]
Masse and Leroux, 1916
Masse, R.; Leroux, L.,
C. R. Hebd. Seances Acad. Sci., 1916, 163, 361. [all data]
Richards and Mathews, 1908
Richards, T.W.; Mathews, J.H.,
The Relation Between Compressibility, Surface Tension, and Other Properties of Material,
J. Am. Chem. Soc., 1908, 30, 8-13. [all data]
Perkin, 1896
Perkin, W.H.,
LXIX. On Magnetic Rotatory Power, especially of Aromatic Compounds,
J. Chem. Soc., 1896, 69, 1025-1257. [all data]
Pinette, 1888
Pinette, J.,
X boiling point and specific volume of a few phenols and phenol ethers,
Justus Liebigs Ann. Chem., 1888, 243, 32. [all data]
Notes
Go To: Top, Normal boiling point, References
- Symbols used in this document:
Tboil Boiling point - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.