Isopropyl acetate

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxCarbowaxDB-WaxOV-351OV-351
Column length (m) 60.60.60.25.25.
Carrier gas HeHe   
Substrate      
Column diameter (mm) 0.320.250.250.320.32
Phase thickness (μm) 1.0.50.25  
Tstart (C) 45.50.50.50.50.
Tend (C) 250.250.230.  
Heat rate (K/min) 5.5.2.6.6.
Initial hold (min) 1.10.   
Final hold (min) 12.10.   
I 913.909.4851.878.878.
ReferenceMalliaa, Fernandez-Garcia, et al., 2005Censullo, Jones, et al., 2003Shimoda, Shigematsu, et al., 1995Korhonen, 1984Korhonen, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Carbowax 20M
Column length (m)  
Carrier gas  
Substrate Celite 545
Column diameter (mm)  
Phase thickness (μm)  
Tstart (C) 75.
Tend (C) 228.
Heat rate (K/min) 4.6
Initial hold (min)  
Final hold (min)  
I 866.
Referencevan den Dool and Kratz, 1963
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Malliaa, Fernandez-Garcia, et al., 2005
Malliaa, S.; Fernandez-Garcia, E.; Bosset, J.O., Comparison of purge and trap and solid phase microextraction techniques for studying the volatile aroma compounds of three European PDO hard cheeses, Int. Dairy J., 2005, 15, 6-9, 741-758, https://doi.org/10.1016/j.idairyj.2004.11.007 . [all data]

Censullo, Jones, et al., 2003
Censullo, A.C.; Jones, D.R.; Wills, M.T., Speciation of the volatile organic compounds (VOCs) in solventborne aerosol coatings by solid phase microextraction-gas chromatography, J. Coat. Technol., 2003, 75, 936, 47-53, https://doi.org/10.1007/BF02697922 . [all data]

Shimoda, Shigematsu, et al., 1995
Shimoda, M.; Shigematsu, H.; Shiratsuchi, H.; Osajima, Y., Comparison of the odor concentrates by SDE and adsorptive column method from green tea infusion, J. Agric. Food Chem., 1995, 43, 6, 1616-1620, https://doi.org/10.1021/jf00054a037 . [all data]

Korhonen, 1984
Korhonen, I.O.O., Gas-Liquid Chromatographic Analyses. XXV. Branched-Chain C3-C5 Alkyl Esters of Halogenated Acetic Acids, J. Chromatogr., 1984, 288, 51-69, https://doi.org/10.1016/S0021-9673(01)93681-7 . [all data]

van den Dool and Kratz, 1963
van den Dool, H.; Kratz, P. Dec., A generalization of the retention index system including linear temperature programmed gas-liquid partition chromatography, J. Chromatogr., 1963, 11, 463-471, https://doi.org/10.1016/S0021-9673(01)80947-X . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, polar column, temperature ramp, References