Propanenitrile

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-1HP-1HP-1HP-1
Column length (m) 30.30.30.30.30.
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm)      
Phase thickness (μm) 3.3.3.3.3.
Temperature (C) 100.110.120.130.140.
I 543.33543.83544.44545.05545.79
ReferenceGörgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-1HP-1HP-1HP-1
Column length (m) 30.30.30.30.30.
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm)      
Phase thickness (μm) 3.3.3.3.3.
Temperature (C) 150.160.170.180.190.
I 546.65547.65548.60549.63550.75
ReferenceGörgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-1HP-1HP-1HP-1
Column length (m) 30.30.30.30.30.
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm)      
Phase thickness (μm) 3.3.3.3.3.
Temperature (C) 20.30.40.50.60.
I 543.13542.69542.41542.29542.32
ReferenceGörgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-1HP-1BPX-5CP Sil 5 CB
Column length (m) 30.30.30.12.25.
Carrier gas N2N2N2H2H2
Substrate      
Column diameter (mm)    0.150.15
Phase thickness (μm) 3.3.3.0.252.
Temperature (C) 70.80.90.30.20.
I 542.38542.60542.90592.545.3
ReferenceGörgényi and Héberger, 2003Görgényi and Héberger, 2003Görgényi and Héberger, 2003Aflalaye, Sternberg, et al., 1995Do and Raulin, 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPackedPackedPacked
Active phase PoraPLOT QPoraPLOT QSE-30Apiezon LApiezon L
Column length (m) 10.10.2.2.32.25
Carrier gas H2H2 N2 
Substrate   Gaschrom QDCMS-treated Chromosorb WCelite
Column diameter (mm) 0.320.32   
Phase thickness (μm) 10.10.   
Temperature (C) 100.160.100.150.130.
I 523.527.547.533.524.
ReferenceDo and Raulin, 1989Do and Raulin, 1989Winskowski, 1983Brown, Chapman, et al., 1968Wehrli and Kováts, 1959
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Apiezon L
Column length (m) 2.25
Carrier gas  
Substrate Celite
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 70.
I 510.
ReferenceWehrli and Kováts, 1959
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Görgényi and Héberger, 2003
Görgényi, M.; Héberger, K., Minimum in the temperature dependence of the Kováts retention indices of nitroalkanes and alkanenitriles on an apolar phase, J. Chromatogr. A, 2003, 985, 1-2, 11-19, https://doi.org/10.1016/S0021-9673(02)01842-3 . [all data]

Aflalaye, Sternberg, et al., 1995
Aflalaye, A.; Sternberg, R.; Raulin, F.; Vidal-Madjar, C., Gas chromatography of Titan's atmosphere. VI. Analysis of low-molecular-mass hydrocarbons and nitriles with BPX5 capillary columns, J. Chromatogr. A, 1995, 708, 2, 283-291, https://doi.org/10.1016/0021-9673(95)00410-O . [all data]

Do and Raulin, 1992
Do, L.; Raulin, F., Gas chromatography of Titan's atmosphere. III. Analysis of low-molecular-weight hydrocarbons and nitriles with a CP-Sil-5 CB WCOT capillary column, J. Chromatogr., 1992, 591, 1-2, 297-301, https://doi.org/10.1016/0021-9673(92)80247-R . [all data]

Do and Raulin, 1989
Do, L.; Raulin, F., Gas chromatography of Titan's atmosphere. I. Analysis of low-molecular-weight hydrocarbons and nitriles with a PoraPLOT Q porous polymer coated open-tubular capillary column, J. Chromatogr., 1989, 481, 45-54, https://doi.org/10.1016/S0021-9673(01)96751-2 . [all data]

Winskowski, 1983
Winskowski, J., Gaschromatographische Identifizierung von Stoffen anhand von Indexziffem und unterschiedlichen Detektoren, Chromatographia, 1983, 17, 3, 160-165, https://doi.org/10.1007/BF02271041 . [all data]

Brown, Chapman, et al., 1968
Brown, I.; Chapman, I.L.; Nicholson, G.J., Gas chromatography of polar solutes in electron acceptor stationary phases, Aust. J. Chem., 1968, 21, 5, 1125-1141, https://doi.org/10.1071/CH9681125 . [all data]

Wehrli and Kováts, 1959
Wehrli, A.; Kováts, E., Gas-chromatographische Charakterisierung ogranischer Verbindungen. Teil 3: Berechnung der Retentionsindices aliphatischer, alicyclischer und aromatischer Verbindungen, Helv. Chim. Acta, 1959, 7, 7, 2709-2736, https://doi.org/10.1002/hlca.19590420745 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References