Benzene, 1,4-dichloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5BP-1BP-1OV-101OV-101
Column length (m) 30.50.50.25.25.
Carrier gas HeliumHeHe  
Substrate      
Column diameter (mm) 0.250.220.220.200.20
Phase thickness (μm) 0.250.750.75  
Tstart (C) 50.50.50.80.80.
Tend (C) 280.200.200.  
Heat rate (K/min) 3.5.5.2.2.
Initial hold (min) 3.    
Final hold (min) 20.    
I 1013.1004.1004.960.970.
ReferenceZenkevich, Moeder, et al., 2004Health Safety Executive, 2000Health Safety Executive, 2000Messadi and Ali-Mokhnache, 1993Messadi and Ali-Mokhnache, 1993
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase OV-101SE-54
Column length (m) 25.25.
Carrier gas  He
Substrate   
Column diameter (mm) 0.200.32
Phase thickness (μm)   
Tstart (C) 80.50.
Tend (C)  250.
Heat rate (K/min) 2.8.
Initial hold (min)  2.
Final hold (min)  12.
I 974.1008.
ReferenceMessadi and Ali-Mokhnache, 1993Harland, Cumming, et al., 1986
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Zenkevich, Moeder, et al., 2004
Zenkevich, I.G.; Moeder, M.; Koeller, G.; Schrader, S., Using new structurally related additive schemes in the precalculation of gas chromatographic retention indices of polychlorinated hydroxybiphenyls on HP-5 stationary phase, J. Chromatogr. A, 2004, 1025, 2, 227-236, https://doi.org/10.1016/j.chroma.2003.10.106 . [all data]

Health Safety Executive, 2000
Health Safety Executive, MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]

Messadi and Ali-Mokhnache, 1993
Messadi, D.; Ali-Mokhnache, S., Calculation of retention indices and peak widths in temperature programmed gas-liquid chromatography, Chromatographia, 1993, 37, 5/6, 264-270, https://doi.org/10.1007/BF02278631 . [all data]

Harland, Cumming, et al., 1986
Harland, B.J.; Cumming, R.I.; Gillings, E., The Kovats indexes of some organic micropollutants on an SE54 capillary column, EUR, I Org. Micropollut. Aquat. Environ., 1986, EUR 10388, 123-127. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References