Benzyl cinnamate

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase BPX-5BPX-5BPX-5BPX-5BPX-5
Column length (m) 30.30.30.30.30.
Carrier gas HydrogenHydrogenHydrogenHydrogenHydrogen
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.250.250.25
Tstart (C) 100.60.60.60.60.
Tend (C) 999.999.999.999.999.
Heat rate (K/min) 3.3.3.3.3.
Initial hold (min)      
Final hold (min)      
I 2135.2134.2135.2138.2141.
ReferenceBieri and Marriott, 2008Bieri and Marriott, 2008Bieri and Marriott, 2008Bieri and Marriott, 2008Bieri and Marriott, 2008
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase BPX-5Equity-5 MS
Column length (m) 30.30.
Carrier gas HydrogenHelium
Substrate   
Column diameter (mm) 0.250.25
Phase thickness (μm) 0.250.25
Tstart (C) 60.40.
Tend (C) 999.260.
Heat rate (K/min) 5.1.5
Initial hold (min)   
Final hold (min)   
I 2146.2096.
ReferenceBieri and Marriott, 2008Mondello, Casilli, et al., 2008
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Bieri and Marriott, 2008
Bieri, S.; Marriott, P.J., Dual-injection system with multiply injections for determining sidimentional retention indexes in comprehensive two-dimensional gas chromatography, Anal. Chem., 2008, 80, 3, 760-768, https://doi.org/10.1021/ac071367q . [all data]

Mondello, Casilli, et al., 2008
Mondello, L.; Casilli, A.; Tranchida, Q.; Sciarrone, D.; Dugo, P.; Dugo, G., Analysis of allergens in fragrances using multiple heart-cut multidimentional gas chromatography - mass spectrometry, LC-GC Europe, 2008, 21, 130. [all data]